Montigo Rio DX Installation, Operation & Maintenance Manual
Montigo Rio DX Installation, Operation & Maintenance Manual

Montigo Rio DX Installation, Operation & Maintenance Manual

Cast stove

Advertisement

Rio DX Cast Stove
HL38DF-PFC Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0512
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
www.montigo.com
Rio DX
Cast Stove
Warning:
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Montigo Del Ray Corp. Ferndale, WA 98248
Installer: Leave this manual
with the appliance.
Consumer: Leave this
manual for future reference.
120507

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rio DX and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo Rio DX

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. ® • Consumer: Leave this manual for future reference. XG0512 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 120507...
  • Page 2: Table Of Contents

    This Stove is certified for use with Montigo Direct Vent Components. Installing the Gasline ............4 The Rio DX Stove is certified as a heating appliance by CGA and AGA tothe Vented Gas Fireplace Heater standard (ANSI Z21.88- Direct Vent Installation ........... 4 2005 ·...
  • Page 3: Installation

    42". (Minimum 1" clearance must be maintained around the vent pipes.) Figure 1. Stove dimensions. Clearances The Rio DX Cast Stove's minimum clearances to combustible materials are: A - Back* 3 ½" B - Control Side†...
  • Page 4: Installing The Gasline

    & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum  Rio Stoves are certified for use with Montigo Standard Series (4" inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" / 7") venting components and approved Vent Kits (listed below) W.C.
  • Page 5 Rio DX Cast Stove Installation Direct Vent Top Vent Venting Runs Installing Terminations with Built-In Frames For the Rio Pedestal Stove there are two types of Top Vent (DV) installations: A) Horizontal (Through-The-Wall) Installations and B) Vertical (Through-The-Roof) Installations. Allowable Vent Runs...
  • Page 6: Terminations

    Additional stove pipe or Montigo Standard Series vent components 4. Cut the horizontal stove pipe (FST11) to length. Slide it and the may be used to increase the vent run, as long as the run still falls 90°elbow and onto the vertical pieces of stove pipe.
  • Page 7 When venting through the roof, use an FSTK04 Vent Kit. Additional Ensure that the intended pathway for the venting is clear.Try to stove pipe or Montigo Standard Series vent components may be position the stove midway between two joists to avoid having to cut used to increase the vent run, as long as the run still falls within the them.
  • Page 8: Removing And Installing The Door

    Rio DX Cast Stove Installation way. Install a spacer spring inside the slip section. Slide the last sec- Removing and Installing tion of standard stove pipe up inside the slip section, again overlap- ping the two by at least half a pipe length.
  • Page 9: Installing The Logset

    Installing the Log Set Wiring Installing the Logs: The Rio DX Stove is supplied with six (6) fibre logs. Unpack the logs Wiring for the optional Blower Kit and handle them very carefully. The Rio Steel Stove may be equipped with an optional variable speed Remove the door cover and the glass door.
  • Page 10: Operation

    Rio DX Cast Stove Operation For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
  • Page 11: Maintenance

    Rio DX Cast Stove Operation Maintenance Lighting Instructions CAUTIONS See pages 12 and 13. Fireplace gas control must be in the “OFF” position and pilot  and main burners extinguished when cleaning appliance with a vacuum. Adjusting the Burner ...
  • Page 12 Rio DX Cast Stove Maintenance Troubleshooting Gas Control Valve HONEYWELL SV9500 /9600 Power Generator Troublshooting Sequence On/Off Switch NOTE: Before Troubleshooting, Familiarize Yourself With The Startup And Checkout Procedure. START INSET CHECK: - Turn Gas Supply Off - Line voltage power...
  • Page 13: Warranty

    Claims against this Warranty in writing should include the date of installation, and a description of the defect. Other Rights Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, with- out notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
  • Page 14: Termination Locations

    Rio DX Cast Stove Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, [*6 feet (1.8 m) minimum] or balcony [16 inches (41 cm) minimum] clearance above paved sidewalk or a paved driveway located on †...
  • Page 15: Accessories And Vent Components

    Rio DX Cast Stove Appendix B - Accessories and Vent Components Accessories Item Description Quantity Order Code Wireless Remote Control RX-40 ON/Off Millivolt Thermostat Programmable RX-60 Therm Millivolt Thermostat Non-programmable Vent Kits Vent Components - Avail. Individually Item Description Quantity Part # Item Quantity/ Pkg.
  • Page 16 Rio DX Cast Stove Appendix B - Accessories and Vent Components Direct Vent - Through-the-Roof Kit Spare Parts List Part Description Part No. NG Gas Valve RGC1021 LP Gas Valve RGC1022 NG Pilot RPA019 LP Pilot RPA019A Door RDRFS1 Front Burner NG...
  • Page 17 Rio DX Cast Stove Appendix A - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 18 Rio DX Cast Stove Notes Page 18 Part No. XG0512...
  • Page 19 Rio DX Cast Stove Notes Page 19 Part No. XG0512...
  • Page 20 XG0512 - 120507 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...

Table of Contents