Pc Compatibility Chart; Rs-232C Port Specifi Cations - Sharp AQUOS LC-37GE1E Operation Manual

Lcd colour television
Table of Contents

Advertisement

Appendix

PC compatibility chart

Horizontal
Resolution
Frequency
640 g 480
VGA
31.5 kHz
800 g 600
SVGA
37.9 kHz
1024 g 768
XGA
48.4 kHz
1360 g 768
WXGA
47.7 kHz
1280 g 1024
SXGA
64.0 kHz
VGA, SVGA, XGA, WXGA and SXGA are registered
trademarks of International Business Machines Co.,
Inc.
NOTE
• This TV has only limited PC compatibility, correct operation
can only be guaranteed if the video card conforms exactly
to the VESA 60Hz standard. Any variations from this
standard will result in picture distortions.
RS-232C port specifi cations
PC Control of the TV
• When a program is set, the TV can be controlled from the
PC using the RS-232C terminal. The input signal (PC/video)
can be selected, the volume can be adjusted and various
other adjustments and settings can be made, enabling
automatic programmed playing.
• Attach an RS-232C cable cross-type (commercially
available) to a 9 pin D-sub/MINI-DIN (optional: AN-A1RS)
for the connections.
NOTE
• This operation system should be used by a person who is
accustomed to using PCs.
9 pin D-sub/MINI-DIN
conversion cable (optional:
AN-A1RS)
RS-232C serial control cable
(cross type, commercially available)
Communication conditions
Set the RS-232C communications settings on the PC
to match the TV's communications conditions. The
TV's communications settings are as follows:
Baud rate:
9,600 bps
8 bits
Data length:
Parity bit:
None
1 bit
Stop bit:
Flow control:
None
Vertical
VESA
Frequency
Standard
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Communication procedure
Send the control commands from the PC via the RS-
232C connector.
The TV operates according to the received command
and sends a response message to the PC.
Do not send multiple commands at the same time. Wait
until the PC receives the OK response before sending
the next command.
Make sure to send "A" with the carriage return and
confi rm that "ERR" returns before operating.
Command format
Eight ASCII codes e CR
C1 C2 C3 C4 P1 P2 P3
Command 4-digits
Parameter 4-digits
Command 4-digits: Command. The text of four characters.
Parameter 4-digits: Parameter 0 – 9, blank, ?
Parameter
Input the parameter values, aligning left, and fi ll with
blank(s) for the remainder. (Be sure that four values are
input for the parameter.)
When the input parameter is not within an adjustable
range, "ERR" returns. (Refer to "Response code
format".)
0
0
0
0
3
0
1
0
0
0
0
5
When "?" is input for some commands, the present
setting value responds.
?
?
?
?
Response code format
Normal response
O
K
Return code (0DH)
Problem response (communication error or incorrect
command)
E
R
R
Return code (0DH)
After sending the return code (0DH), make sure to send
line feed (0AH) as well.
P4
Return code
9
5
?
35