IMPORTANT NOTICE
Pellet Vent Pipe or PL Vent Pipe Must be used.
                          Fig. 6
  + = Positive static pressure
     =  Negative static pressure
Inlet Cover part#
1-10-08543
Fig. 7
Venting
Outside air flex pipe
goes here
Flex pipe part#
2-00-08543
A combustion blower is used to extract the com-
bustion gases from the firebox. This causes a nega-
tive pressure in the firebox and a positive pressure
in the venting system as shown in fig. 6. The longer
the vent pipe and more elbows used in the system,
the  greater  the  flow  resistance.  Because  of  these
facts we recommend using as few elbows as pos-
sible and 15 feet or less of vent pipe. The maximum
horizontal run should not exceed 48". If more than
15 feet of pipe is needed, the diameter should be
increased from 3" to 4" because a larger pipe causes
less  flow  resistance.  Be  sure  to  use  approved
pellet  vent  pipe  wall  and  ceiling  pass  through
fittings  to  go  through  combustible  walls  and
ceilings. Be sure to use a starting collar to attach
the venting systen to the stove. The starting collar
must be sealed to the stove with high temp sili-
cone caulking.
Vent  Pipe
Pellet venting pipe ( also known as PL vent ) is
constructed  of  two  layers  with  air  space  between
the layers. This air space acts as an insulator and
reduces the outside surface temperature to allow a
clearance  to  combustibles  of  only  3  inches.  The
sections of pipe lock together to form an air tight seal
in  most  cases;  however,  in  some  cases  a  perfect
seal  is  not  achieved.  For  this  reason  and  the  fact
that the P61 operates with a positive vent pressure
we  specify  that  the  joints  also  be  sealed  with
clear silicone.
Outside Air
Outside air is optional except in mobile homes
and where building codes require.  The benefit of
outside  air  is  mainly  noticed  in  small  very  tight
houses.
To  install  outside  air  use  2  3/8"  I.D.  flex  pipe
part number 2-00-08543. There is a break-away hole
on  the  rear  panel  which  must  be  removed  before
connecting the flex pipe. The pipe should be run out-
side and terminate to the side or below the vent pipe
outlet so the flue outlet is more than 12" from the
inlet cover.The maximum length run of this pipe is
15 feet. If a longer run is needed the size must be
increased to 3". Inlet cover part number 1-10-08542
should be used to keep birds, rodents etc. out of  the
pipe.
HRV
When installing in a house with a Heat Reclaim-
ing Ventilation System (HRV) be sure the system is
balanced and is not creating a negative pressure in
the house.
 7