If you are using an extension cord outdoors, make sure it is marked with the
suffix "W-A" ("W" in Canada) to indicate it is acceptable for outdoor use.
7.
Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified
electrician before using it. Protect your extension cords from sharp objects,
excessive heat, and damp or wet areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
NAMEPLATE
AMPERES
(At Full Load)
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
7.1-12.0
12.1-16.0
16.1-20.0
FIGURE B
FIGURE C
SKU 92281
For technical questions, please call 1-800-444-3353.
(115 VOLT)
EXTENSION CORD LENGTH
25
50
FEET
FEET
18
18
18
18
18
18
18
16
16
14
14
12
12
10
*Based on limiting the line voltage drop
to five volts at 150% of the rated amperes.
SYMBOLOGY
Double Insulated
Canadian Standards
Association
Underwriters
Laboratories, Inc.
V ~
Volts Alternating Current
A
Amperes
no
No Load Revolutions
xxxx/min.
per Minute (RPM)
75
100
FEET
FEET
18
18
18
16
16
14
14
12
12
10
10
-
-
-
150
FEET
16
14
12
12
-
-
-
PAGE 7