Newton Security T-DAR T2010MT Installation And Operation Manual

T-dar tailgating / piggybacking detection system two head mantrap
Table of Contents

Advertisement

Quick Links

®
T-DAR
TAILGATING / PIGGYBACKING DETECTION SYSTEM
Installation and Operation Manual
Two Head Mantrap
T-DAR Model T2010MT
Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T-DAR T2010MT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Newton Security T-DAR T2010MT

  • Page 1 ® T-DAR TAILGATING / PIGGYBACKING DETECTION SYSTEM Installation and Operation Manual Two Head Mantrap T-DAR Model T2010MT Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com...
  • Page 2 (THIS PAGE BLANK) Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com...
  • Page 3 ® T-DAR TAILGATING / PIGGYBACKING DETECTION SYSTEM Installation and Operation Manual Two Head Mantrap T-DAR Model T2010MT Revised: 040212 Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com...
  • Page 4: Table Of Contents

    7. CONFIGURATION AND SETUP OF T-DAR SOFTWARE Connect and Verify Camera Functionality Configuring the T-DAR System About T-Dar User Interface Software Connection Menu Debug Menu Initial Setup Monitor Tab Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com...
  • Page 5 Troubleshooting 9. DETAILED SPECIFICATIONS – CB210MT Control Box Power Specifications DC Input Specifications Relay Output Specifications Upper Front Panel Connections Connection Details Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 2 of 58...
  • Page 6: Introduction

    Standard Operating Temperature: 40° to 125° F (5° - 52 ° C) (optional high and low temperature systems available) Storage Temperature: 0° to 150° F (-18° - 66 ° C) (continued) Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 3 of 58...
  • Page 7 Mounting: via 12 x 0.25 in. (6.35 mm) holes (three on each side tab). Camera Mounting: via 4 x 1/8 in. (3.175 mm) holes on top panel. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 4 of 58...
  • Page 8: Tips For A Successful T-Dar Installation

    The maximum length of a mantrap with cameras above 9 ft. (2.74m) is 10 ft. (3.00m)  The maximum width of a mantrap with cameras above 9 ft. (2.74m) is 5 ft. (1.50m). Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 5 of 58...
  • Page 9 Use a material that will not show excessive dirt or tracks.  Flooring may be of any color, although we recommend using a color that does not show dirt or tracks. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 6 of 58...
  • Page 10 An external 24V DC power supply with a peak current of 10 Amps is required.  A power supply is NOT included with the T-DAR system. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 7 of 58...
  • Page 11 Failure to supply Line lock input signal if low frequency fluorescents are utilized in the mantrap may cause erratic system operation. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 8 of 58...
  • Page 12: Basic Installation

    +12VDC. The system will not operate without a reference jumper for each input. Typical T-DAR outputs and inputs - Note the position of the Secure Door Public Valid reader Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 9 of 58...
  • Page 13: Component Mounting

    WARNING: Do not modify the T-DAR control unit, by cutting or drilling. This will void the warranty and surely cause damage to the unit. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 10 of 58...
  • Page 14: Stereo Tracking Head Mounting

    Center the cameras lengthwise so that the distance from camera to door is equal on both ends. Note: if the ceiling is less than 8.5 ft. (2.6m), consult Newton Security technical support before proceeding.
  • Page 15 One (1) CAT5 cable (straight through) from Annunciator to control panel on port “Annunc 1”.  An adequate number of wires to support the inputs and outputs utilized on the system. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 12 of 58...
  • Page 16: Integration With The Access Control System

    There is no option for setting the relay outputs to normally closed.  All input grounds are common  A jumper between +12VDC and common generates a reference voltage for all inputs Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 13 of 58...
  • Page 17: Access Readers - Public And Secure Doors

    Public and Secure Valid Access Connections Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 14 of 58...
  • Page 18: Door Lock Control

    Note: in this option, the mantrap will only have one door locked at a time. As in Option 1, both doors cannot open at the same time. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 15 of 58...
  • Page 19: Annunciator Unit

    WARNING: plugging in a camera head (CAT5 cable) into an annunciator port or using a crossover cable to connect a camera, may damage the control unit or camera head. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 16 of 58...
  • Page 20: Door Contact Switch

    T-DAR lock output to the doors.  Supervisor override is input 1 on the T-DAR control box, which corresponds to B1 on the front T-DAR panel. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 17 of 58...
  • Page 21  With an active override signal and both doors closed, any valid access signal to T-DAR will unlock the secure door. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 18 of 58...
  • Page 22: Installing Software

    The included Control Unit install disk is only required for backup purposes. User Interface There should be only one Newton Security user interface installed on a computer at any time. If you are having trouble running T-DAR software, it may be a result of version conflicts with previously installed T-DAR software.
  • Page 23: Connecting Via The User Interface

    If the IP address of the control unit has changed, enter the latest address. 5. Follow the on-screen instructions. Note: the T-DAR controller is shipped with the control box application preinstalled Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 20 of 58...
  • Page 24: Configuration And Setup Of T-Dar Software

    This base calibration will then allow the system to recognize objects introduced into the scene and track them, while ignoring objects that are normal to the scene. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 21 of 58...
  • Page 25: About T-Dar User Interface Software

    Upon a violation or alarm event, the T-DAR system records the occurrence and immediately outputs the video from the BNC or VGA video port.  Newton Security recommends the use of an external DVR system if permanent storage of event video is required. ...
  • Page 26: Connection Menu

    Connect establishes communication between the UI application and the T-DAR hardware. You must establish a connection before performing UI operations. With the T-DAR IP configured, selecting Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 23 of 58...
  • Page 27: Debug Menu

    Without proper training, seek assistance before making changes using this menu. WARNING: Making improper changes to the Debug Menu may result in unexpected behavior. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 24 of 58...
  • Page 28 Display Page Size - Shows screen resolution.  Old-Style Saves Settings - This is another way to save settings to a file. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 25 of 58...
  • Page 29: Initial Setup

    When using a controller newer than 2011, do not adjust this setting. On units built before 2011, choose NTSC or PAL depending on the video output required. Reboot the unit after making changes to this setting. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 26 of 58...
  • Page 30: Monitor Tab

    The statistics may be reset using the Reset Event Statistics button on the Setup I/O page. Note: There are no installer configurable items on this page. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 27 of 58...
  • Page 31 Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 28 of 58...
  • Page 32 Note: Once event playback is complete, the video sequence ceases to exist; the T-DAR system does not store event video. Newton Security recommends the use of an external DVR system if permanent storage of event video is required. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com...
  • Page 33: Inputs And Outputs

    T-DAR controller with the monitor turned on and plugged in to the video output port. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 30 of 58...
  • Page 34 Note: To unlock the secure door, both doors must be closed and the headcount in the mantrap must be either 1 or 0, depending on whether the public reader or the secure reader is accessed. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 31 of 58...
  • Page 35: Setup I/O

    The End time defines the end of the event video relative to the time of the violation. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 32 of 58...
  • Page 36: Time

    Note: be sure that the image is current each time the picture is referenced. Update the image by clicking on “Update Now”. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 33 of 58...
  • Page 37: Configuration

     Option 3) the static scan occurs after a public access grant, located on the secure door, inside the mantrap. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 34 of 58...
  • Page 38: Setting Scan Zones

    If the public door is left open, dynamic scanning will continue indefinitely. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 35 of 58...
  • Page 39 Adjust both dynamic regions so that they do not pick up objects outside of the mantrap, i.e. people walking on the other side of a glass window. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 36 of 58...
  • Page 40: Crawling

    Be sure that the mantrap is calibrated and that the Cart sensitivity is not lower than 30 inches. Set the Crawler sensitivity above 400 when there is excessive sunlight, dirt, or tracking on the floor. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 37 of 58...
  • Page 41: Entry From Public / Exit To Public

    Minimum head size is too small. These objects include anything over cart height, such as door hardware, arms, hands, hoods, and any carried objects. (continued) Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 38 of 58...
  • Page 42: L2, L3, L4 And Maximum Head Size

    They may be standing next to another person. A small amount of trial and error may be necessary to account for these occasions. (continued) Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 39 of 58...
  • Page 43: Cart Sensitivity

    Objects that are considered crawlers will cause an alarm. A typical value for Crawler Sensitivity is 350. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 40 of 58...
  • Page 44: Installer I/O

    If no changes are observed on the screen during testing, verify wiring of device to T-DAR. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 41 of 58...
  • Page 45: Setup Of Outputs

    Use the same process as changing Installer Password. If the administrator password becomes lost, contact the T-DAR system installer or Newton Security. Change Installer Password Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 42 of 58...
  • Page 46 This tab allows you to see the activity of the system, when doors open and close, what alarms have been active and what inputs and outputs have been triggered Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 43 of 58...
  • Page 47: Advanced Tab

    ‘x’ inches passed the public head’ will need to be set to -10. Values above this do not work for cameras mounted in a parallel orientation. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 44 of 58...
  • Page 48: Critical Elements To Maintain Proper Operation

    Minimum head size until one of the crosses disappears. Note: More accurate results will be obtained if the subject is wearing dark clothing. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 45 of 58...
  • Page 49: Test The Dynamic Scan Areas

    Note: More accurate results will be obtained if the subject is wearing dark clothing. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 46 of 58...
  • Page 50: Front Panel Indicator Led's On The Cb210 Control Unit

    No Power to the unit Green Power supplied and breaker is not tripped Power supplied and breaker is tripped Power Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 47 of 58...
  • Page 51: Changing The Voice Announcements Via The Built-In Microphone

    8. Replace and secure the cover with the (6) 6/32 Phillips head screws. Note: if recording voices into a microphone is not desirable, contact Newton Security for other methods of adding new announcements. This will require sending the unit to Newton Security for programming.
  • Page 52: Troubleshooting

    Call your Newton Security Inc. Authorized Distributor Arrange with your local distributor to substitute a working T-DAR unit and laptop to determine where the problem exists. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 49 of 58...
  • Page 53 Point the Imager at a bright light. If the live image is entirely black, then contact your Newton Security Inc. Authorized Distributor. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 50 of 58...
  • Page 54 The Image Is Too  Decrease the illumination source or number of sources. Bright  Replace the stereo camera head if problem persists. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 51 of 58...
  • Page 55 If you cannot reposition the unit properly, connect the control unit to the host computer and redo setup in the user interface Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 52 of 58...
  • Page 56  The system may be un-calibrated. Calibrate the T-DAR system. Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 53 of 58...
  • Page 57: Detailed Specifications - Cb210Mt Control Box

    ON to OFF Response 0.2 mSec Typical Auxiliary Power Outputs +5 VDC Incorporated over-current breaker +12 VDC Incorporated over-current breaker +24 VDC Incorporated over-current breaker Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 54 of 58...
  • Page 58: Upper Front Panel Connections

    Output, 15 pin VGA for connection of computer monitor for local system control. Video Out: Output, BNC connector to video monitor for set-up and monitoring Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 55 of 58...
  • Page 59: Connection Details

    General 2 connector. Also, a bond wire from the external power supplies ground terminal will need to be placed in the Ground terminal as well to provide for ground bonding. RS232 TX Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 56 of 58...
  • Page 60 The valid access grant switch will connect to the Portal Digital Input terminal and to either ground or +12v (or applicable source voltage) dependent upon installation type. Input 2 and 7 to 14 Not Used Newton Security Inc | 443 SW 41st St. Renton, WA. 98057 USA | www.newtonsecurityinc.com Page 57 of 58...

Table of Contents