Gas Conversions - Maytag MGR7661WS0 Installation Instructions Manual

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

Available languages

Available languages

GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
Install a shut-off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion,
or fire.
1,
2.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
Turn the manual shutoff valve to the closed position.
Unplug range or disconnect power.
...................
B
A_
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
To Convert Gas Pressure Regulator
1. Remove storage drawer or warming drawer. See "Replace
Oven Racks and Storage or Warming Drawer" section.
2. Locate gas pressure regulator at rear of storage or warming
drawer compartment.
NOTE: On models with a warming drawer, an access cover
must be removed from the gas pressure regulator.
A,
A. Gas pressure regulator
3,
4.
IMPORTANT: Do not remove the gas pressure regulator.
Remove plastic cover from gas pressure regulator cap.
Turn gas pressure regulator cap counterclockwise
with a
5/8"combination
wrench to remove.
NOTE: Do not remove the spring beneath the cap.
B
F
Side view before
F
C
Side view after
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
F. Gas regulator shutoff valve (shown in the "open" position)
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the hollow end faces out and the marking
"<- LP" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
12