Kingston Technology Data Express DE100i-SWD User Manual

Removable scsi drive enclosure with 16-bit wide differential i/o
Table of Contents

Advertisement

Kingston Technology
DATA EXPRESS
Removable SCSI Drive Enclosure
With Wide Differential I/O
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Data Express DE100i-SWD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingston Technology Data Express DE100i-SWD

  • Page 1 Kingston Technology DATA EXPRESS Removable SCSI Drive Enclosure With Wide Differential I/O User's Guide...
  • Page 2 DE100i-SWD Removable SCSI Drive Enclosure with 16-Bit Wide Differential I/O User's Guide Part No. D89-0000-0012 C00 December 1997 Kingston Technology Company 17600 Newhope Street Fountain Valley, CA 92708-9885 Phone (714) 438-1850 Fax (714) 438-1847 DE100i-SWD User's Guide - Rev. C00...
  • Page 3: Limited Warranty

    Limited Warranty KINGSTON TECHNOLOGY COMPANY (“Kingston”) warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by Kingston on an exchange basis, and will be either new or refurbished to be functionally equivalent to new.
  • Page 4: Ce Declaration Of Conformity

    CE Declaration of Conformity Company’s Name: Kingston Technology Company Storage Products Division Company’s Address: 17600 Newhope Street Fountain Valley, CA 92708 Manufacturer’s Address: 11535 Martens River Circle Fountain Valley, CA 92708 Product Name: Data Express DE100i Model Number: DE100i-XSXX/XXX Conforms to the following specifications:...
  • Page 5: Table Of Contents

    Table of Contents DATA EXPRESS DE100i-SWD ....................1 Packaging Materials ...................... 1 Package Contents ......................2 Serial Numbers ......................2 General Description ....................... 3 The Receiving Frame Front Panel ..............4 The Receiving Frame Rear Panel ..............5 DATA EXPRESS INSTALLATION ..................6 Installing the Drive into the Carrier ................
  • Page 6 List of Figures Figure 1: Data Express DE100i-SWD Package Contents ..........1 Figure 2: DE100i-SWD Receiving Frame and Carrier ............2 Figure 3: Receiving Frame Front Panel ................4 Figure 4: Unit Number Display Conditions ................. 5 Figure 5: Receiving Frame (Rear View) ................5 Figure 6: Drive Installation Assembly .................
  • Page 7: Data Express De100I-Swd

    9. 6-32 by 3/16" Phillips F.H. Mounting Screws Drive Lock Keys Receiving Frame 10. 1.25mm/2mm ID Select Cable Drive Carrier 11. Single Row Wire Wrap Connector User's Guide Figure 1: Data Express DE100i-SWD Package Contents DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 8: Package Contents

    Kingston Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number labels and record the numbers in the spaces provided below. Receiving Frame: Drive Carrier: Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 9: General Description

    Introduction General Description ® The Kingston Technology Data Express DE100i-SWD is a removable drive carrier and receiving frame designed to provide durable and reliable mounting for 3.5” SCSI drives within 5.25" half-height peripheral slots (Figure 2). The Data Express allows a drive to be removed and transported to another Data Express- equipped computer or expansion chassis, and also provides the ability to secure sensitive data by removing and storing the drive safely for future use.
  • Page 10: The Receiving Frame Front Panel

    Carrier Guide Count Mating Connector All Steel Receiving Frame Device Spin Down/Up Timer Unit Number Display Receiving Frame Front Activity Indicator Key/Lock and Power Switch 0231 Figure 3: Receiving Frame Front Panel Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 11: The Receiving Frame Rear Panel

    P4, P6 = Ground Enable Termination Power To/From Ground SCSI BUS Reserved Jumpers Remote ID 68-Pin = Pin 1 Installed I/O Connector Select at Factory 0408B Figure 5: Receiving Frame (Rear View) DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 12: Data Express Installation

    Disk drives use a row of pins to provide ground to the ID signals. This row of pins is not used when installing the ID select cable to the carrier connector. Refer to the drive manufacturer's documentation for more information. Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 13: Installation

    Drive Mounting Hardware (4ea) Cable Cover Phillips # 6-32 x Screws (2 plcs) 3/16 Flat HD # 6-32 x 3/16 Flat HD 0151 Figure 6: Drive Installation Assembly DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 14: Figure 7: Typical Scsi Id Select Connections (2Mm Drive Pins)

    5-PIN WIRE WRAP CONNECTOR (Provided). Use in place of ID Select Cable if there is not enough space. Disk Carrier 0142 Figure 7: Typical SCSI ID Select Connections (2mm Drive Pins) Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 15: Installing The Receiving Frame

    Jumpers Installed at Factory Ground Receiving Frame Motherboard Connector J4 From System ID0 From System ID1 From System ID2 0427B From System ID3 Reserved Figure 8: Receiving Frame Connector J4 Pin Configuration DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 16: Figure 9: Receiving Frame Mounting Holes

    Make sure that only the last SCSI device is terminated. The Differential Data Express does not contain on-board SCSI termination. If it is the last SCSI device, set the termination from the expansion chassis. Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 17: Selecting The Unit Number

    Refer to Figure 10 for the location of the Unit Select Switch inside the receiving frame. After selecting an appropriate unit ID number, replace the Data Express carrier in the receiving frame, and LOCK IT IN PLACE. DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 18: Figure 10: Unit Select Switch Location

    Receiving Frame Drive Carrier (removed) 0179A Figure 10: Unit Select Switch Location Table 3: 16-Bit Wide Differential Unit ID Display DISPLAY DISPLAY UNIT UNIT (HEX) (HEX) NUMBER ( NUMBER ( 0147 Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 19: Scsi Interface Connector J2

    -SEL +C/D +REQ -C/D -REQ +I/O GROUND -I/O -GROUND +DB(8) +DB(9) -DB(8) -DB(9) +DB(10) +DB(11) -DB(10) -DB(11) NOTE: The hyphen preceding a signal name indicates that the signal is active low. DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 20 Installation Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 21: Appendices

    Appendix A - Specifications/Dimensions Appendices DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 22: Appendix A - Specifications/Dimensions

    1.5lb. (.68kg) 1lb (.45kg) Plus weight of installed disk drive. With carrier removed. Chassis Reliability/Maintainability MTBF 500,000 Hours MTTR 5 Minutes Preventive Maintenance None Electrical Specifications Input 65mA 400 µ A +12V Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 23: Figure A-1: Data Express Physical Dimensions

    .250 3.125 (6.4) (3.8) (16.3) (79.4) #6-32 x 4 Bottom Carrier Only 1.68 7.38 (187.5) (42.7) 4.665 3.75 (95.3) (118.5) .245 1.75 0285A (6.2) (44.5) Figure A-1: Data Express Physical Dimensions DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 24: Appendix B - Factory-Installed Options

    Board into position. Make certain that all connectors are properly mated. Attach the Hot Swap Board to the receiving frame motherboard by using the two screws removed earlier and insert them through the Hot Swap Board into the standoffs. Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 25: Figure B-1: Attaching The Hot Swap Board

    After a short length of time the unit display will turn from a flashing unit number to a steady “u”, indicating that the device is powered down, unlocked and ready to be removed from the receiving frame. DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 26: Figure B-2: Device Spin Down/Up Timer

    D = 75 SECONDS 6 = 40 SECONDS E = 80 SECONDS 7 = 45 SECONDS F = 85 SECONDS Front of 0143B Receiving Frame Figure B-2: Device Spin Down/Up Timer Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 27: Figure B-3: Hot Swap Board Jumper Options

    Ground I/O Connector Pin 1 0637 DC Power I/O Interface Connector Connector Hot Swap Device Activity SCSI Receiving Frame Board (Carrier Installed) Monitor Jumper Figure B-3: Hot Swap Board Jumper Options DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 28: Solenoid Drive Lock

    Shown with Outer Shell of Receiving Frame Removed Spin-Down Timer Solenoid Control Pivoting Lock Mechanism Rotating Pawl 0286 Figure B-4: Solenoid Mechanism Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 29: Appendix C - Attaching The On/Off Key To Non-Solenoid Units

    5. Reinstall the pawl into the access hole with the adjustment tool.. Your key is now attached to the key/lock mechanism. 0156 Figure C-1: Attaching the On/Off Key DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 30: Appendix D - Optional Accessories

    7” long x 9” wide x 3.5” high, make it easy to carry and to store. The foam lining is contoured to fit a single Data Express carrier. Contact your Kingston dealer for further details and ordering information. Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 31: Drive Cover

    NOTE: The Data Express drive cover may not be compatible with all 3.5" half-height drives. Exact drive height and fit within the Data Express frame can vary between drive manufacturers. Please contact Kingston Storage for technical assistance before ordering the Data Express drive cover. DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...
  • Page 32: Write Protect Switch

    The write protect switch bracket will replace it. Attach the write protect connector to the appropriate drive pins. Refer to the device manufacturer's instructions for pin locations. Attach the SCSI cable and power connectors. Kingston Technology Company DE100i-SWD User's Guide - Rev. C00...
  • Page 33: Drive Plug

    The purpose of the plug is to provide an attractive and functional method of directing proper air flow to the other installed devices in the system or external enclosure. DE100i-SWD User's Guide - Rev. C00 Kingston Technology Company...

Table of Contents