L.P. CONVERSION
INSTRUCTIONS
WARNING:
Thisconversionmust be performed
bg a qualified installeror gas supplier
in accordancewith the
manufacturer's instructionsand all
codes and requirementsof the
authority havingjurisdiction. Failure
to follow ALLinstructions could result
in seriousinjury or property
damage.Thequalified agency
performing this work assumes
responsibilityfor the conversion.
The pressure regulator and the burner
orifices are set for natural gas. To use
Liquid Propane Gas,the regulator and
burner orifices must be converted. The
L.R orifices for the cooktop burners are
shipped on the regulator bracket behind
the storage drawer. Also, in the same
area, is a second bracket holding the L.R
!5K orifice extended spud, choke and set
screw for the front right Extra Large
cooktop burner (on models so equipped).
Remove the storage drawer to locate.
A WARNING:
Do not operate the cooktop or oven
burners of this range when using L.R
(bottled) gas before converting the
pressure regulator and burner orifices
for L.R gas use. Failure to do so could
cause high flames and toxic fumes
which can result in serious injury.
To
adjust
your range for usewith L.Rgas,
follow these instructions:
!. Disconnectall electricalpower,at the
main circuit breakeror fuse box.
2. Shutoff the gas supply to the range bg
closing the manual shut-off valve.
a.
Raise the cooktop and locate the
pressure regulator.
b.
Follow the direction in 1Aor 1B
depending on your regulator
type.