INSTALLATION
INSTRUCTIONS
Downflow
Vent
Guard
Kit No:
NAHAOO2VC
This kit is designed
for use on the N8MPN,
N8MPL, *8MPN,
*8MPL, *8MPT, & *8MPV when
used
in downflow
applications.
* Denotes Brand (T, H or C)
Please
read
these
instructions
completely
before
attempting
installation.
Safety
Considerations
Installing
and servicing
of heating
equipment
can be hazardous
due to gas and electrical
components.
Only trained
personnel
should
install or service
heating
equipment.
Untrained
personnel
can perform
basic
maintenance
such as
cleaning
and replacing
filters. All other operations
should
be per-
formed
by trained
service
personnel.
When
working
on heating
equipment,
observe
precautions
in the literature,
on tags, and on
labels attached
to the unit. Follow all safety codes.
Wear safety
glasses
and work
gloves.
Have
a fire extinguisher
available.
Recognize
safety
information.
/'_
This is the safety-alert
symbol. When you see this symbol
on the furnace and in instructions or manuals, be alert to the po-
tential
for personal
injury.
Understand
the
signal
words
DANGER, WARNING, CAUTION, and NOTE. These words are
used with the safety-alert
symbol. DANGER identifies the most
serious hazards which will result in severe personal injury or
death. WARNING signifies a hazard which could result in per-
sonal injury or death. CAUTION is used to identify unsafe practic-
es which would result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which
will result in enhanced installation, reliability, or operation.
CUTS AND ABRASION
HAZARD
Failure to follow
this caution
may result
in personal
injury.
Sheet
metal
parts
may have
sharp
edges
or burrs.
Use
care
and
wear
appropriate
protective
clothing
and
gloves
when
handling
parts.
INTRODUCTION
To protect
against
exposed
hot surfaces,
the downflow
vent
guard
should
always
be used when
the vent
pipe
is installed
along the outside
of the furnace
casing in a downflow
a pplication.
This
kit is designed
for single-
or double-wall
4" pipe.
Type B
vent
connector
after
the
Vent
Guard
is REQUIRED
for
all
2-stage
furnace
applications.
TABLE 1
Kit Contents
DESCRIPTION
PART NO,
QUANTITY
Vent Guard
328552-4
1
Vent Guard Top
328553-4
1
Vent Guard Bottom
328554-4
1
Vent Cover Plate
328555-4
1
Screw
HEX HD 8B 3/8
10
Installation Instructions
441 06 1045 00
1
Operating Instructions
1013494
1
Warning Label
1013810
1
INSTALLATION
NOTE: Vent Guard may be installed on the left or right side of the
furnace.
1.
Bend
tabs on the Vent Cover
Plate up and insert
below
opening,
then
bend tabs down
over top of furnace.
(See
Figure
1).
Vent Cover
Plate Installation
Bend
Slightly
Bend
Greater
25-24-58
2.
With
the
furnace
in
the
downflow
orientation,
drill
four(4)1/8 " holes thru the casing
as indicated
by dimples
on the furnace.
Printed in U.S.A
441 06 1045 01 (2/2004)

Advertisement

loading

Summary of Contents for ICP H8MPT100J20A1

  • Page 1 INSTALLATION INSTRUCTIONS Downflow Vent Guard Kit No: NAHAOO2VC This kit is designed for use on the N8MPN, N8MPL, *8MPN, *8MPL, *8MPT, & *8MPV when used in downflow applications. * Denotes Brand (T, H or C) Please read these instructions completely before attempting installation.
  • Page 2 Attach vent pipe and elbow to Furnace vent outlet with at Position Vent Guard Top on Guard (See Figure 4). Bend least two field supplied corrosion resistant sheet metal centering tabs equally. screws located 180 ° apart at each connection joint.

This manual is also suitable for:

H8mpn150j20a1H8mpt075f14a1H8mpv125j20a1H8mpt125j20a1H8mpt100f14a1H8mpv075f14a1 ... Show all