1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check
the following
parts
before
installation.
<Indoor
unit>
(1)
Installation
plate
1
Attachment
screws
for the installa-
(2)
tion plate
5
4x25mm
(3)
Remote
controller
holder
1
Screws
for the remote
controller
(4)
holder
2
3.5 x 16 mm (Black)
(5)
Battery
(AAA)
for (6)
2
(6)
Wireless
remote
controller
1
(7)
Felt tape
(For left or left-rear
piping)
1
(8)
Anti-Allergy
Enzyme
Filter
1
(9)
Platinum
deodorizing
filter
1
FIELD-SUPPLIED
PARTS
(A)
Indoor/outdoor
unit connecting
wire*
1
(B)
Extension
pipe
1
(C)
Wall hole sleeve
1
(D)
Wall hole cover
1
(E)
Pipe attachment
strap
2 to 5
(F)
Screw for (E) 4 x 20 mm
2 to 5
(G)
Piping
tape
1
(H)
Putty
1
Drain hose
(or soft PVC hose,
19/32
in. [15 mm]
2 to 5
(I)
inner diameter
or hard PVC pipe
VP16)
(J)
Refrigerant
oil
1
(K)
Power
supply
cord
1
* Note:
Place indoortoutdoor
unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
f
Use the wall
hole
sleeve
(C) to prevent
indoortout-
door
connecting
wire
(A)
from
contacting
metal
parts
in the wall
and
to
protect
the wiring
from
rodents.
_[_,_JWall
hole cover (D)
I
indoor unit _Seal
thewall
hole
]
Wal_ hole'
VfJ//
"m
sleeve (C)_
I [
I Attach!hepipe.to
|
• ' _/_j_-_
wall with pipe at-
|
r//tt_
[ tachrnent strap (E). I
Cut off the
Pipe attachment
extra length. _strap
(E)
Attachment
screw (F)
_"After
the leak
test,
apply
insulating
mate-
]
Lrial
tightly
so that there
is no gap.
J
When
the piping
is to be attached
to a wall
comprised
of tin plate or metal
netting,
use
chemically
treated
wooden
piece
25/32
in.
(20 ram)
or thicker
between
the wall
and
the piping,
or wrap
insulation
vinyl
tape
7
to 8 turns
around
the piping.
To use existing
piping,
perform
COOL
operation
for 30 minutes
and
pump
down
before
removing
the old air conditioner.
Remake
flare
according
to the dimension
for new refrigerant.
Open two sides of
left, right, or rear
side.
Units should be installed by licensed contractor
accord ng to oca code requ rements.
Basically open 4 in.
(100 mm) or more
without any obstruction
in front and on both
sides of the unit.
4 in.
(100 ram)
or more
Unit: inch
31-1/2
5_
19-11/16
_L_
43- Air inlet
42.
_r__/16
f
Air outlet
2-3/8 × 13/16 stot
Unit:
mm
800
500
1
_
"_
Ai_r_nlet
40
_
2 10 x 21 slot
Air outlet