DISCONTINUED User Manual Edition: 08-23-2011 THOR-E Digital KVM/DVI Extender Model: TH-E Series Telecast Fiber Systems A Belden Brand 102 Grove Street Worcester, MA 01605 www.telecast-fiber.com Tel. +1 508-754-4858 Fax +1 508-752-1520...
Contents Contents About This Manual ............... 7 Scope.................. 7 Validity ................7 Cautions and Notes............. 7 Safety Instructions ............... 8 Description ................... 9 Application ................9 System Overview .............. 10 Product Range ..............11 3.3.1 Basic Modules............. 11 3.3.2 Upgrade Modules..........11 3.3.3 USB 2.0 Modules ..........
Page 4
THOR-E Extender 3.6.15 USB 2.0 Module TH-E-(R or L)-UPD-4USB-CAT 20 3.6.16 USB 2.0 Module TH-E-(R or L)-UPD-4USB- (MM/SM) ............. 21 Status LEDs ..............22 3.7.1 Status Basic Module ........... 22 3.7.2 Status Basic Module VGA / DVI-I......23 3.7.3 Status Upgrade Module Digital Audio ....24 3.7.4 Status Upgrade Module USB-HID.......
Page 5
Contents 7.1.9 Digital Audio Interface......... 41 08-23-2011...
THOR-E Extender About This Manual Scope This manual describes how to install your THOR-E Extender, how to operate it and how to perform trouble shooting. Validity This manual is valid for all devices listed on the front page. The product code is printed on the base of the devices.
THOR-E Extender Safety Instructions To ensure reliable and safe long-term operation of your THOR-E Extender please note the following guidelines: Installation Only use in dry, indoor environments. The THOR-E Extender and the power supply units can get warm. Do not situate them in an enclosed space without any airflow. Do not place the power supply directly on top of the device.
THOR-E Extender Description Pos : 4 /806-IH SE/Besc hrei bung/Ver wendungsz wec k/474- xx @ 6\mod_1304579672848_6.doc @ 50785 @ 2 Application The THOR-E Extender is used to increase the distance between a source (computer, CPU) and its console (keyboard, mouse, and other peripheral devices).
THOR-E Extender System Overview The THOR-E Extender of the TH-E series consists of at least one CPU Unit and one console unit (CON Unit). The THOR-E modules are summarized respectively in a THOR-E case (2-modules, 4-modules or 6- modules) at CPU site and CON site.
THOR-E Extender Product Range 3.3.1 Basic Modules Model Description TH-E-L-UPD-1-SL-2-X Single-Head Module for 1x DVI-D Single Link (up to 1920x1200) with 2x USB-HID TH-E-R-UPD-1-SL-2-X TH-E-L-UPD-1-SL-2-X-V Single-Head Module for 1x DVI-I (VGA / DVI) Single Link (up to 1920x1200) with 2x USB- TH-E-R-UPD-1-SL-2-X-V 3.3.2 Upgrade Modules...
CPU Unit: TH-E-L CON Unit: TH-E-R All devices of the TH-E series are technically compatible to the devices of the legacy series. Pos : 7 /806-IH SE/Besc hrei bung/Einbauoptionen/474- xx @ 6\mod_1304580008551_6.doc @ 50839 @ 2...
THOR-E Extender Upgrade Kits Model Description TH-ACCS-146 19"/1U rack mount kit for 2-, 4- and 6-modules chassis TH-ACCS-147 Fastening strips for screw or snap on for 2-, 4- and 6- modules chassis TH-ACCS-148 Retrofitting for redundant power supply option (without power supply) for 2- and 4-modules chassis TH-ACCS-149 Power supply for 2-modules chassis (spare or...
THOR-E Extender 3.6.3 6-modules THOR-E Chassis CPU and CON Unit Rear View Slot for modules 5 Slot for modules 3 Slot for modules 1 Connect to power supply (standard) Connect to 5VDC power supply (standard) Slot for modules 6 Slot for modules 4 Slot for modules 2 Pos : 13 /806-IHSE/Besc hreibung/Geräteansichten/474- xx/Basis-Baugruppe L- / R 474-BSHC @ 6\mod_1304580479441_6.doc @ 50912 @ 3 3.6.4...
THOR-E Extender 3.6.5 Basic Module TH-E-(R or L)-UPD-1-SL-2-(MM/SM) CPU Module CON Module Rear View Rear View Service port Service port Connect to interconnect cable Connect to interconnect cable To CPU: USB-HID Connect to USB-HID devices To CPU: DVI-D Connect to DVI monitor Pos : 15 /806-IHSE/Besc hreibung/Geräteansichten/474- xx/Basis-Baugruppe L- / R 474-BSHCV @ 6\mod_1304583420910_6.doc @ 50948 @ 3 3.6.6 Basic Module TH-E-(R or L)-UPD-1-SL-2-CAT-V...
THOR-E Extender 3.6.7 Basic Module TH-E-(R or L)-UPD-1-SL-2-(MM/SM)-V CPU Module CON Module Rear View Rear View Service port (KVM) Service port Connect to interconnect cable Connect to interconnect cable To CPU: USB-HID Connect to USB-HID devices To CPU: DVI-I (VGA / DVI) IR receiver for remote control IR receiver for remote control Connect to DVI monitor...
THOR-E Extender 3.6.9 Upgrade Module TH-E-(R or L)-UPD-A232 CPU Module CON Module Rear View Rear View Connect to serial (D-Sub 9) Connect to serial (D-Sub 9) Audio IN Audio IN Audio OUT Audio OUT Pos : 19 /806-IHSE/Besc hreibung/Geräteansichten/474- xx/U pgrade- Baugruppe L- / R474-BDX @ 6\mod_1304583577801_6.doc @ 51020 @ 3 3.6.10 Upgrade Module TH-E-(R or L)-UPD-DA CPU Module CON Module...
THOR-E Extender 3.6.16 USB 2.0 Module TH-E-(R or L)-UPD-4USB-(MM/SM) CPU Module CON Module Rear View Rear View Service port Service port Connect to interconnect cable Connect to interconnect cable To CPU: USB 2.0 Connect to USB 2.0 devices Pos : 26 /806-IHSE/Besc hreibung/Diagnos e LED s/UEB_Diagnos e_LEDs @ 6\mod_1304584004723_6.doc @ 51146 @ 2 08-23-2011...
THOR-E Extender Status LEDs Pos : 27 /806-IHSE/Besc hreibung/Diagnos e LED s/474- xx/Di agnose Basis-Baugruppe @ 6\mod_1304584091941_6.doc @ 51165 @ 3 3.7.1 Status Basic Module The basic module is fitted with a multi color LED on both sides for overall status indication and with two further LEDs on the back side for indication of the connection status.
THOR-E Extender Pos : 28 /806-IHSE/Besc hreibung/Diagnos e LED s/474- xx/Di agnose Basis-Baugruppe VGA / DVI-I @ 6\mod_1304584132098_6.doc @ 51183 @ 3 3.7.2 Status Basic Module VGA / DVI-I The basic module with VGA / DVI-I input is fitted with a multi-color LED on the front side of the CPU Unit for indication of connection status.
THOR-E Extender 3.7.3 Status Upgrade Module Digital Audio The upgrade module digital audio is fitted with a further multi-color LED on the rear side for indication of the connection status: CPU Unit CON Unit Rear View Rear View LED 1: Digital Audio Status LED color Description No signal...
THOR-E Extender 3.7.4 Status Upgrade Module USB-HID The upgrade module USB-HID is fitted with three further LEDs on the rear side for indication of the connection status: CPU Unit CON Unit Rear View Rear View Pos. LED Status Description 1, 2 No USB-HID device or not supported Device LED (orange)
THOR-E Extender 3.7.5 Status USB 2.0 Module The USB 2.0 module is fitted with a multi color LED on both sides for overall status indication and with two further LEDs on the back side for indication of the connection status. CPU Unit CON Unit Rear View...
THOR-E Extender Installation Pos : 33 /806-IHSE/Ins tall ati on/Li eferumfang pr üfen/474- xx @ 6\mod_1304584334582_6.doc @ 51255 @ 2 Package Contents Your extender package contains the following items: Basic Modules: THOR-E Extender pair (CPU Unit and CON Unit) in the THOR-E box 1x (redundancy 2x) 5VDC international power supply unit per THOR- E Extender unit 1x (redundancy 2x) country specific power cord...
Page 28
THOR-E Extender Additional content for upgrade module Digital Audio: RCA cable (2.5 m, Cinch male connector) TOSLINK cable (1.8 m, F05 male connector) Additional content for upgrade module USB-HID: USB cable (1.8 m, USB type A to type B) Additional content for USB 2.0 module: USB cable (1.8 m, USB type A to type B) If anything is missing, contact your dealer.
THOR-E Extender System Setup First time users are recommended to setup the system with the CPU Unit and the CON Unit in the same room as a test setup. This will allow you to identify and solve any cabling problems, and experiment with your system more conveniently.
THOR-E Extender 4.2.2 Setup of Upgrade Modules The modules can be hot plugged. Upgrade Module Analog Audio / Serial: Connect the audio source with the CPU Unit (e.g. CPU audio output with audio input, CPU audio input with audio output). Connect the audio output at the CON Unit with headphones or suitable speakers.
THOR-E Extender Example Applications This section illustrates typical installations of THOR-E Extenders: Pos : 36 /806-IHSE/Ins tall ati on/Installati onsbeispi ele/477- xx_C OMP @ 5\mod_1291124264328_6.doc @ 44767 @ THOR-E Extender (Single-Head) THOR-E Extender (Single-Head with Digital / Analog Audio) 08-23-2011...
Page 32
THOR-E Extender THOR-E Extender (Dual-Head with 4x USB-HID) Source (computer, CPU) THOR-E Extender CPU Unit Interconnect cable THOR-E Extender CON Unit Console (monitor, keyboard, mouse) Second monitor (option, only with Dual-Head devices) USB-HID devices (option, only with 4x USB-HID devices) Audio sink (optional, only with devices with Analog Audio / Serial option or Digital Audio option) Pos : 37 /806-IHSE/Konfig urati on/UEB_Konfiguration @ 5\mod_1278575517073_6.doc @ 41846 @ 1...
THOR-E Extender Configuration Pos : 38 /806-IHSE/Konfig urati on/Übertr agungs parameter /477- xx @ 5\mod_1278937002401_6.doc @ 43075 @ 2 Transmission Parameters The device operates with a proprietary compression method. In default configuration, the device adapts dynamically to monitor resolution and image content. This configuration is suitable for almost all conditions and should only be modified if image quality is not fully satisfactory.
THOR-E Extender DDC Settings By default, the device sends the factory preset DDC information to the CPU. This information is suitable in most cases. The download of the DDC information of the console monitor can be performed during normal operation (see Chapter 6.1, Page 36). For special requirements, DDC information can be retrieved and uploaded as a binary file at both the CPU Unit and the CON Unit.
THOR-E Extender Command Mode During normal use, the console keyboard functions in the usual manner. However, for all KVM Extenders with USB-HID support, you can set the keyboard into a Command Mode by using a specific 'Hot Key' sequence. While in Command Mode, several functions are performed via keyboard commands.
THOR-E Extender Operation Pos : 42 /806-IHSE/Betrieb/Laden von DDC-Infor mationen/477- xx @ 5\mod_1278937455136_6.doc @ 43130 @ 2 Download of DDC Information By default, data from the internal DDC list is reported to the source (computer, CPU). If these settings do not lead to a satisfying result, the DDC information of the console monitor can be downloaded and stored internally.
THOR-E Extender Other USB-HID devices The proprietary USB emulation also supports certain other USB-HID devices, such as specific touch screens, graphic tablets, barcode scanners or special keyboards. Support cannot be guaranteed, however, for every USB-HID device. Only two USB-HID devices are supported concurrently, such as keyboard and mouse or keyboard and touch screen.
THOR-E Extender 7.1.7 Serial Interface The serial interface option supports a full-duplex transmission with a real hardware handshake up to a Baud rate of 19,200 Baud. The CON Unit is cabled as DTE (Data Terminal Equipment, like CPU output) and can be connected directly to DCE devices (Data Communication Equipment).
THOR-E Extender 7.1.8 Analog Audio Interface The Analog Audio option supports a bidirectional stereo audio transmission, in nearly CD quality. audio interface is a 'line level' interface and it is designed to transmit the signals of a sound card (or another 'line level' device) as well as to allow the connection of active speakers to the CON Unit.
THOR-E Extender 7.1.9 Digital Audio Interface The digital audio option supports the unidirectional transmission of digital audio data. Up to three sources can be connected to the CPU Unit. The active source is transmitted. If several sources are active, the XLR signal takes priority, otherwise the first active signal.
THOR-E Extender Interconnect Cable Pos : 56 /806-IHSE/T ec hnische D aten/Verbi ndungs kabel/Verbi ndungs kabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 7.2.1 Cat X A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Switch, is not allowed.
THOR-E Extender 7.2.2 Fiber A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active network components, such as Ethernet Hubs, Switches or Routers, is not allowed. Type of Interconnect Cable (Cable notations according to VDE) Type of cable Specifications Single-mode 9µm...
THOR-E Extender Supported Peripherals Pos : 61 /806-IHSE/T ec hnische D aten/Getestete Peri pherie/USB-HID-Geräte @ 5\mod_1278578523558_6.doc @ 42260 @ 3 7.3.1 USB-HID Devices The THOR-E Extender will support most USB-HID devices, including the vast majority of keyboards and mice currently on the market. Many other kinds of HID device such as bar-code scanners and touch screens may also be compatible It is not possible to guarantee support for all available USB-HID devices.
THOR-E Extender Connector Pinouts Pos : 64 /806-IHSE/T ec hnische D aten/Pi nbel egungen/Buc hs e DVI-D Si ngle-Li nk @ 5\mod_1278578723073_6.doc @ 42333 @ Connector DVI-D Single-Link 1......8 17......24 Pin Signal Pin Signal Pin Signal T.M.D.S data 2– T.M.D.S data 1– 17 T.M.D.S data 0–...
Page 46
THOR-E Extender Connector DVI-I Single-Link 1......8 17......24 Pin Signal Pin Signal Pin Signal T.M.D.S data 2– T.M.D.S data 1– 17 T.M.D.S data 0– T.M.D.S data 2+ T.M.D.S data 1+ 18 T.M.D.S data 0+ T.M.D.S data 2 T.M.D.S data 1 T.M.D.S data 0 n.c.
Page 47
THOR-E Extender Connector USB Type A Picture Signal Color VCC (+5VDC) Data – White Data + Green Black Pos : 68 /806-IHSE/T ec hnische D aten/Pi nbel egungen/Buc hs e Mini-U SB T yp B @ 5\mod_1278578794167_6.doc @ 42387 @ Connector Mini USB Type B Picture Signal...
Page 48
THOR-E Extender Power Supply Picture Signal Inside VCC (+5VDC) Outside Pos : 72 /806-IHSE/T ec hnische D aten/Pi nbel egungen/D-Sub 9 (Seriell) @ 5\mod_1291128631437_6.doc @ 44882 @ D-Sub 9 (Serial) Picture Signal Signal n.c. 1....5 6...9 n.c. Pos : 73 /806-IHSE/T ec hnische D aten/Pi nbel egungen/Ster eo- Klinkenbuchse 3,5 mm @ 5\mod_1291128765156_6.doc @ 44901 @ 3.5 mm Stereo Jack Plug Picture Signal...
THOR-E Extender Mini-XLR Picture Signal 1 3 2 Data + Data – Pos : 76 /806-IHSE/T ec hnische D aten/Pi nbel egungen/TOSLINK @ 5\mod_1291129073656_6.doc @ 44958 @ TOSLINK Picture Diode Signal Data IN / OUT Pos : 77 /806-IHSE/T ec hnische D aten/Stromversorgung/474- xx @ 6\mod_1304586284191_6.doc @ 51327 @ 2 Power Supply 5VDC Voltage...
THOR-E Extender Size Devices in the 2-modules THOR-E case 145 x 130 x 41 mm (5.7" x 5.1" x 1.6") CPU Unit / CON Unit 210 x 140 x 165 mm (8.3" x 5.5" x 6.5") Shipping Box Devices in the 4-modules THOR-E case 293 x 130 x 41 mm (11.5"...
THOR-E Extender Troubleshooting Pos : 82 /806-IHSE/Hilfe i m Probl emfall/Bildausfall/474- xx @ 6\mod_1304586526379_6.doc @ 51381 @ 2 Blank Screen CPU Unit CON Unit Rear View Rear View Diagnosis Possible Reason Measure LED 3 off Power supply Check power supply units and the connection to the power network.
THOR-E Extender USB-HID at the Basic Module CPU Unit CON Unit Rear View Rear View Diagnosis Possible Reason Measure Keyboard LEDs Keyboard in Command Press <Esc> to leave Command Shift and Scroll Mode Mode. are blinking CPU Unit: No USB connection to Check connection of USB cable LED 3 green or to CPU;...
THOR-E Extender Serial Connection Upgrade Module Diagnosis Possible Reason Measure Serial device Settings of the serial Check Baud rate and general not operational interface settings. No serial connection to Check connection via serial cable. No serial connection to Connect serial end device and end device (e.g.
THOR-E Extender Digital Audio Upgrade Module CPU Unit CON Unit Rear View Rear View Diagnosis Possible Reason Measure CPU Unit: No audio connection to Connect digital audio source. LED 1 red CPU / audio source Check connection of audio cable. No signal Switch digital audio source on.
THOR-E Extender USB-HID Upgrade Module CPU Unit CON Unit Rear View Rear View Diagnosis Possible Reason Measure LED 1 / 2 off Device at higher / lower Check connection of USB cable USB-HID port not to USB-HID device. detected Connect USB-HID device. Contact dealer if necessary.
THOR-E Extender USB 2.0 Upgrade Module CPU Unit CON Unit Rear View Rear View Diagnosis Possible Reason Measure CPU Unit: No connection to CPU Check connection USB cable to All LEDs off CPU; select another USB port if necessary. Remove USB and power cable and restart CPU.
THOR-E Extender Technical Support Prior to contacting support please ensure you have read this manual, and then installed and set-up your THOR-E Extender as recommended. Support Checklist To efficiently handle your request, please keep the following information available before you call: Company, name, phone number and email Type and serial number of the device (see bottom of device) Date and number of sales receipt, name of dealer if necessary...
THOR-E Extender Regulatory and Standards Compliance Pos : 91 /806-IHSE/Z ertifi kate/ATB_Eur opäisc he Konformitätser kl ärung @ 5\mod_1278579640901_6.doc @ 42686 @ 2 10.1 CE Declaration Of Conformity All the products presented in this manual comply with the provisions of the following European Directives: 2004/108/EG Council Directive on the approximation of the laws of...
THOR-E Extender cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
THOR-E Extender Glossary The following terms are commonly used in this guide or in video and KVM technology: Term Explanation AES/EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices. Cat X Any Cat 5e (Cat 6, Cat 7) cable The Color Graphics Adapter (CGA) is an old analog...
Page 61
THOR-E Extender Term Explanation DVI-I A combined signal (digital and analog) that allows running a VGA monitor at a DVI-I port – in contrast to DVI-D (see DVI). Fiber Single-mode or multi-mode fiber cables The Enhanced Graphics Adapter (EGA) is an old analog graphic standard, introduced by IBM in 1984.
Page 62
THOR-E Extender Term Explanation TOSLINK Standardized fiber connection system for digital transmission of audio signals (F05 plug connection) Triple-Head A system with three video connections USB-HID USB-HID devices (Human Interface Device) allow for data input. There is no need for a special driver during installation;...
Need help?
Do you have a question about the TH-E Series and is the answer not in the manual?
Questions and answers