Daishiba DSP?45HCA User Manual

Air source swimming pool heat pump
Hide thumbs Also See for DSP?45HCA:

Advertisement

Air Source Swimming Pool

Heat Pump

‐ USER MANUAL ‐
DSP-45HCA
DSP-65HCA
DSP-85HCA
DSP-100HCA
DSP-120HCA
DSP-180HCA
DSP-180HCA/3
DSP-230HCA
DSP-230HCA/3
DSP-260HCA/3

Advertisement

Table of Contents
loading

Summary of Contents for Daishiba DSP?45HCA

  • Page 1: Heat Pump

    Air Source Swimming Pool Heat Pump ‐ USER MANUAL ‐ DSP-45HCA DSP-65HCA DSP-85HCA DSP-100HCA DSP-120HCA DSP-180HCA DSP-180HCA/3 DSP-230HCA DSP-230HCA/3 DSP-260HCA/3...
  • Page 2 Swimming pool heat pump To our customers Note! Dear customers, thank your for your kind support to our products. Please read this instruction carefully before the installation and application of this product. The precautions listed below are all-important for safety. Please follow the instructions strictly. Attention 1.
  • Page 3: Table Of Contents

    Swimming pool heat pump Content Product brief instruction………………………….…………….……………………………………..3 Technical data....................4 Unit dimension…………………………………………………………........6 Installation………………………………………………………………........8 Electric connection………………………………………………………………......14 Controller operation instruction………………..………………………………………………….19 Maintenance & Troubleshooting………………………….…………………………………..…23 - 2 -...
  • Page 4: Product Brief Instruction

    Swimming pool heat pump PRODUCT BRIEF INSTRUCTION 1.1 Performance High efficiency With a COP value more than 4.9, our heat pumps are very efficiency when transferring heat from the air to the swimming pool water. It can save as much as 80% of cost compared to an electric heater.
  • Page 5: Technical Data

    Swimming pool heat pump TECHNICAL DATA Swimming pool heat pump Model DSP‐45HCA DSP‐65HCA DSP‐85HCA DSP‐100HCA DSP‐120HCA Heating Capacity* (KW) Heating Input (KW) 0.86 1.32 1.55 1.98 2.44 Heating Capacity** 11.3 13.5 (KW) Heating Input (KW) 0.91 1.35 1.61 2.49 Cooling Capacity (KW) (Optional) Cooling Input (KW)
  • Page 6 Swimming pool heat pump Swimming pool heat pump Model DSP‐180HCA DSP‐180HCA/3 DSP‐230HCA DSP‐230HCA/3 DSP‐260HCA/3 Heating Capacity* (KW) Heating Input (KW) 3.61 5.21 Heating Capacity** (KW) Heating Input (KW) Cooling Capacity (KW) (Optional) Cooling Input (KW) Heating Rated 16.5 9.06 10.2 Current (A) Max.
  • Page 7: Unit Dimension

    Swimming pool heat pump UNIT DIMENSIONS Horizontal models A(mm) B(mm) C(mm) D(mm) E(mm) Model DSP-45 HCA DSP-65(85) HCA DSP-100 HCA 1118 DSP-120 HCA 1140 - 6 -...
  • Page 8 Swimming pool heat pump Vertical models DSP-180HCA, DSP-180HCA/3, DSP-230HCA, DSP-230HCA/3 DSP-260HCA/3 - 7 -...
  • Page 9: Installation

    Swimming pool heat pump INSTALLATION Note! Installation must be carried out by professional staff. Installation position 1. The unit must be installed on reliable base or framework. Weight capacity of framework should be 3 times of the body weight, and safeguard measures should be taken to avoid malfunction of fastenings.
  • Page 10 Swimming pool heat pump 4. To install the unit at balcony or top of building, the installation site must meet the allowable bearing capacity of building structure, without affecting the structural safety. 5. Ensure the unit is well ventilated. Virtually the unit may be installed anywhere outdoors providing minimum distance requirements are met with respect to other objects.
  • Page 11: Distance From The Pool

    Swimming pool heat pump Model: vertical unit 6. The unit should not be installed at places accompanied with oil, inflammable gas, corrosive components e.g. sulfur compound, or high-frequency equipment. 7. The unit should not be installed at sites with typhoon/earthquake hazards. Midair installation should be avoided as much as possible as machine falling down may result in severe accident.
  • Page 12: Swimming Pool Water Chemistry

    Swimming pool heat pump ℃ per 30 meters could roughly be estimated at 0.6 kW/ hour for every 5 mperature difference between the pool water and the soil surrounding the pipe, which translates to an operation time increase time increase of 3-5%. Swimming pool water chemistry Special attention should be paid to the chemical balance of the pool water.
  • Page 13 Swimming pool heat pump Project Installation sketch map - 12 -...
  • Page 14 Swimming pool heat pump Attention 1. The water flow can not be lower than the unit standard value (please refer to the nameplate). 2. The insulation of water pipe should be done well to prevent energy loss. 3. A suitable draining valve should be installed in the bottom point of water system. 4.
  • Page 15: Electric Connection

    Swimming pool heat pump ELECTRIC CONNECTION Note! Electrical installation and service must be carried out under the supervision of a qualified electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. Wires, spare parts and materials etc. must satisfy the relevant standards issued by the host country or region.
  • Page 16 Swimming pool heat pump Circuit diagram Model: DSP-45HCA, DSP-65HCA, DSP-85HCA, DSP-100HCA - 15 -...
  • Page 17 Swimming pool heat pump Model: DSP-120HCA - 16 -...
  • Page 18 Swimming pool heat pump Model: DSP-180HCA, DSP-230HCA - 17 -...
  • Page 19 Swimming pool heat pump Model: DSP-180HCA/3, DSP-230HCA/3, DSP-260HCA/3 - 18 -...
  • Page 20: Controller Operation Instruction

    Swimming pool heat pump CONTROLLER OPERATION INSTRUCTION Operation panel - 19 -...
  • Page 21 Swimming pool heat pump When power on, the green indicator lamp, beside the “ON/OFF” button, will light. Under standby state, the time and water temp. show on the display screen. 1. Button instruction ◆ ON / OFF Switch button ◆ Cyclic time When the timer on / timer off are set, press this button, the unit will start or stop according to the set time everyday.
  • Page 22 Swimming pool heat pump ◆ Mode Press this button to change heating/cooling mode. ◆ Inquiry Press this button to inquire temperature of each detector; or adjust and reset some parameters of the unit license Press the “Inquiry” button, entering into the parameter checking mode Code Instruction Water outlet temperature...
  • Page 23 Swimming pool heat pump Parameter Instruction Range Default Mark Defrosting interval time 20 - 80 min 45min Defrosting running time 3 - 15 min 6min Compressor exhaust temp. protection 100 - 125℃ 110℃ Low pressure time set 1-15min 5min Low pressure environment temp. -5℃...
  • Page 24: Maintenance & Troubleshooting

    Swimming pool heat pump MAINTENANCE & TROUBLESHOOTING Maintenance Check water supply device and drainage often. Make sure avoid the condition of no water or ● air entering into system, as this will influence unit’s performance and reliability. Clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of clogged filter.
  • Page 25 Swimming pool heat pump Code Fault Check Solution 1. Remove jam or adjust the water flow bigger. 2. Clean the 10. On heating code: check if there evaporimeter is jam in water circuit system or regularly, make sure the water flow not enough the fan runs well and 11.

Table of Contents