Control Box Overview; Field Wiring Shield; Thermostat Installation - Evcon EB12B Installation Manual

Eb series downflow/upflow electric furnace
Table of Contents

Advertisement

035-15266-003
Rev. A(0804)
SEQUENCERS C IRCUIT
BREAKERS
THERMOSTAT
WIRES
J
TRANSFORMER
L
LIMIT
SWITCHES
J
®
/
/
II
,L
@
®
®
_
OI
}
O0
@
3500-378P*
JUMPER
BARS
(FOR
SINGLE
J
BRANCH
CIRCUIT
SERVICE)
NOTE:
AS SHIPPED, THE JUMPER
BAR
ASSEMBLY
IS SET-UP FOR
BOTTOM
ENTRY. FOR SiDE
ENTRY, THE TOP LUG CAN BE
REMOVED
AND RE-POSITIONED,
AS SHOWN, TO PROVIDE
PROPER
WIRE BENDtNG
CLEARANCES,
_GROUND
LUGS
FIGURE 13 : CONTROL BOX
_WARNING
For personal
safety
be sure
to turn
the electrical
power
"OFF"
at the household
service
box
and at
the furnace
circuit
breakers
before
attempting
any
service
or maintenance
operations.
Homeowners
should
never
perform
any
maintenance
which
requires
opening
electric
box door.
Furnace
is equipped
with a protective
shield
over
field
wiring
connection.
When
field
wiring
is com-
pleted,
shield
must be replaced
to prevent
hazard
of
electrical
shock
when
using
furnace
disconnect.
(See Figure
14.)
BLOWER
CIRCUIT
BREAKERS
ELECTRIC
//PANEL
FIELD WIRING
J
PROTECTIVE
SHIELD
THERMOSTAT
INSTALLATION
The adjustable
heat anticipator
in the thermostat
is pre-set
at
0.4 Amps.
This
setting
should
be checked
at the time
of
installation
In some
cases
the thermostat
may be a "self-setting"
type in
which
case no Amp.
setting
will be found
on the thermostat,
eliminating
the need for any field adjustment.
Thermostat
should
be located
on an inside
wall
in an open
area
to more
closely
regulate
average
room
air, preferably,
where
there is air movement
back to furnace.
Care should
be
used to locate thermostat
away from
hot air discharge
open-
ings,
lights,
etc.
Locating
height
of thermostat
is important.
Thermostat
should
be located
52 to 66 inches
above
the
floor. This is sometimes
called
the comfort
zone.
If a condenser
with
its own Transformer
shares
a Heat/Cool
Thermostat
with this furnace,
use a thermostat
with
isolating
contacts
to prevent
interconnection
of Class
II 24 Volt Sys-
tems.
Cycle furnace
to make sure it will operate
correctly.
Maintenance
and operating
instructions
are in the customer
envelope
accompanying
the furnace.
Give the customer
envelope
to the home
owner.
FIGURE 14 : FIELD WIRING SHIELD