UL Listed Models When operating at elevated temperature extremes, the surface may exceed +75°C. For user safety, the 2080E-T should be installed in a restricted access location. The openings on the enclosure are for air convection. Protect the equipment from overheating. Do not cover the openings.
Page 3
Cooper Bussmann/ELPRO Technologies. The offer or supply of these products and services does not include or infer any transfer of ownership. Release Notice This is the November 2013 release of the 2080E-T Managed Ethernet Switch User Manual version 1.0, which applies to firmware version 1.10. Follow Instructions Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or servicing this equipment.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 1 - INTrODUCTION hapTEr The 2080E-T Managed Ethernet Switch is is an 8-Port 10/100 TX switch that provides a cost effective solution that meets the high reliability requirements demanded by industrial applications. 1.1 Module Identification The identification label is located on the bottom of the 2080E-T Switch.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 1.3 Order Information Item Product Code Description Data Sheet Ethernet Switch 2080E-T 8 Port 10/100TX Managed Ethernet Switch 10102 1.4 Hardware Features Feature Description Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE802.3x Flow Control and Back Pressure...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Feature Description Safety UL, cUL, CE/EN60950-1 UL Class 1 Division II for Group A, B, C and D Hazardous Location Stability Testing IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) 1.5 Software Features...
Each port allows importing 128-bits of alphabetic string on SNMP and CLI interface 1.6 Package Contents Compare the contents of the 2080E-T Switch with the following standard content list. If any item is damaged or missing, contact your local dealer for service.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 2 - harDWarE DESCrIpTION hapTEr This chapter describes hardware specifications, ports, cabling information, and wiring installation information for the 2080E-T. 2.1 Front Panel The front panel includes eight 10/100 TX RJ-45 ports, one RS-232 connector (RJ-45 type) for connecting to a console (terminal or PC), a pin-hole reset button, and diagnostic LEDs.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 2.2 Top View The top panel of the 2080E-T Switch includes one terminal block connector. The terminal block has two DC power inputs and one fault alarm. Figure 4 Top Panel of 2080E-T Switch 2.3 LED Indicators...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 2.4 Pin-hole Reset Button Pressing the pin-hole reset button for more than five seconds will cause the 2080E-T to return to its factory default settings. www.cooperbussmann.com/wirelessresources Rev Version 1.0...
3.2 DIN Rail Mounting The 2080E-T normally ships from the factory with the DIN rail mount kit installed. If the DIN rail is not installed, refer to Figure 5 to screw the DIN rail onto the switch. Then, follow the steps to mount the switch.
3.3 Wall Mount Plate Mounting Follow these steps to mount the switch using a wall mount plate. 1. Loosen the screws to remove the DIN rail from the 2080E-T Switch. 2. Place the wall mount plate on the rear panel of the switch.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 3.4 Wiring the Power Inputs Use the following steps below to insert the power wire. 1. Insert the DC power wires into the contacts for power 1 and power 2, as shown below.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 3.5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector, as shown in Figure 6. Insert the wires into the fault alarm contacts. After the wires are inserted, the switch detects the fault status of the power failure or port link failure, and then forms an open circuit.
Pro-Ring2se is a new ring mechanism for the Cooper Bussmann/ELPRO Technologies Industrial Ethernet Switches. As Figure 10 shows, Pro-Ring2se can be constructed using two ports of the same type in each 2080E-T. Refer to the section “6.5.5 Redundancy - Pro-Ring2se” for information on configuring each switch to enable the Pro-Ring2se feature.
Page 18
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 10 Pro-Ring2se Connection Example www.cooperbussmann.com/wirelessresources Rev Version 1.0...
A RS-232 to RJ-45 connector cable is supplied with the switch (Figure 11). Connect the RS-232 connector to PC or terminal and the RJ-45 connector to the console port of the 2080E-T switch. The connected terminal or PC must support a terminal emulation program, such as HyperTerminal or PuTTY.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • Baud Rate: 9600 bps • Data Bits: 8 • Parity: none • Stop Bit: 1 • Flow control: none Figure 13 Communication Parameters 3. After setting the communication parameters, click OK.
6.1 Preparing for Web Management Before using the Web-based Management Utility, install the 2080E-T Switch on the network and make sure that all PCs on the network can connect with the switch through the Web browser. The default IP address, subnet mask, username, and password for the 2080E-T Switch are as follows: • IP Address: 192.168.1.88...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.3 Web Page Overview The Web-based Management Utility uses a standard Web interface with the menu tree on the left. Click expand a menu, and click to collapse a menu. You can also expand or collapse the entire menu tree by clicking Open All or Close All.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 17 Switch Information Page System Name System name of the switch. System Description Switch description. System Location Physical location of the switch. System Contact Name of contact person or organization. System OID SNMP OID of switch.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual System Name Assign the system name of the switch (the maximum length is 64 bytes). System Description Switch description. System Location Physical location of the switch (the maximum length is 64 bytes).
SNTP server. When disabled, local time is used without any SNTP server information. NOTE when SNTP is enabled, a network connection between the 2080E-T switch and the SNTP server is required for the SNTP client within the switch to receive and synchronize time information to the time provided by the SNTP server.
Page 26
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Daylight Saving For non-US and European countries, specify the amount of time for day light Offset savings. You can specify between 0 and 12 hours. Apply Click to apply the settings. Table 1...
Click to apply the settings. 6.4.4 IP Addressing – IPV4 The 2080E-T Switch needs to be assigned an IP address that identifies it on the network. You can select a method of assigning IP address to the switch by choosing System-->IP Addressing-->IPV4.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual IP Address Enter a static IP address to the switch from the subnet address range that the network is using. If the DHCP Client option is enabled, the switch is configured as a DHCP client.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Syslog Log To display the current system event log (Figure 24), choose System-->Syslog-->Log. Click Reload or press F5 to refresh the page to view the most recent events. Figure 24 Log Page Reload Reloads the current log.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 25 SNMP Agent Configuration Agent Mode Select the SNMP version (V1/V2c or V3) that you want to use. And then click Apply to switch to the selected SNMP version mode. SNMP V1/V2c...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • DC power status trap • Topology change trap Figure 26 SNMP - Trap (Trap Manager) Server IP Enter the IP address of the trap manager. Community Enter the community string for the trap station.
Page 32
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual An item of management information may exist in more than one context. An SNMP entity potentially has access to many contexts. In other words, if an item of management information has been defined under a certain context by an SNMPv3 entity, any management application can access that information by providing that context name.
Page 33
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Use the Group tab to configure the SNMPv3 group table The group name created in this tab is associated with the user ID. Both the group name and the user ID are used as parameters to create entries in the access table that appears in the Access tab.
Page 34
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Current Access Lists the existing access table profiles. Tables Context Prefix Enter the context prefix to be used to identify the context name. Group Name Enter the group name associated with this access profile.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Current MIB Tables Lists the existing MIB views. View Name Enter the name of the MIB view to be added (or removed). Sub-OID Tree Enter the OID defining the root of the subtree to which the view will be included or excluded.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual NOTE If you also want the port event log to be sent to the Syslog server, be sure to set the triggers (link up, link down, and both) in the Port Alert page (see “Port Alert”).
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 34 DHCP Server Configuration DHCP Server Enable or disable the DHCP server function on the switch. When enabled, the switch will be the DHCP server on your local network. Start IP Address Enter the IP address that is the beginning of the dynamic IP address range.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 36 IP Binding Apply Click to apply the setting. 6.5 Configure Menu 6.5.1 Port Port Configuration To configure the settings of each port to control the connection parameters, choose Configure-->Port-->Configuration. The status of each port is listed at the bottom of the page.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Flow Control Flow control determines whether the receiving node sends feedback to the sending node. Three options are available: • Disable—Disables flow control capability. • Symmetric—Flow control is determined by auto-negotiation, and is only used when both linked ports have flow control enabled.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 39 Port Statistics Port Port number. Type Displays the current speed of connection to the port. Link Current link status: • Up—Link is operational. • Down—Link is not operational. State State set on the Port Configuration page (see “6.5.1 Port”). When the state is disabled, the port will not transmit or receive packets.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual To display this page, choose Configure-->Port-->Port Alert. Figure 40 Port Alert Port Event For the Port Event menus to become available, the “Client Only” option in Syslog Configuration must be enabled (see “6.4.5 Syslog”).
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 41 Rate Limit Egress Setting Allows you to set the egress rate limit (in kbps) for each port. The range is from 100 kbps to 102400 kbps (100 Mbps). Note that 1 Mbps is equal to 1024 kbps. Zero indicates no egress rate limit.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Ingress Limit Select the frame type to be filtered: Frame Type • All • Broadcast/Multicast/Flooded Unicast • Broadcast/Multicast • Broadcast only Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast, and Broadcast only types are only for ingress frames. The egress rate only supports the “All” type.
In this configuration, if a working port fails, one of the non- working ports will be brought in to carry traffic in place of the failed working port. The 2080E-T Switch uses IEEE 802.3ad LACP protocol to negotiate an agreement with its member ports.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual RSTP Settings The Spanning Tree - RSTP Settings page provides the bridge and port configuration interface for RSTP. You can assign a higher or lower priority to each port. When RSTP is enabled, the port with the higher priority is in the forwarding state and other ports are blocked to make certain there is no loop in the LAN.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual The rapid state transitions possible within RSTP depend on whether the port concerned can only be connected to a specific bridge (it is served by a point-to-point LAN segment), or can be connected to two or more bridges (it is served by a shared medium LAN segment).
The number of seconds a port waits before changing from Rapid Spanning Tree Protocol learning and listening states to the forwarding state. 6.5.5 Redundancy - Pro-Ring2se To configure Pro-Ring2se function on the 2080E-T Switch, choose Configure-->Redundancy-->Pro-Ring2se. For examples of Pro-Ring2se connection options, see “4.1 Pro-Ring2se Application.” Figure 47 Pro-Ring2se Pro-Ring2se Enable or disable the Pro-Ring2se function.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Control VLAN ID Because the Pro-Ring2se master switch generates BPDU packets every 10 ms to check the connection status, and the same BPDU packet is used by other switches to find a target switch, it is better to isolate the BPDU packets used for checking connection status from those used for other purposes.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual NOTE There must be at least one switch that is enabled for IGMP query in your network. All other switches must enable IGMP snooping. Figure 48 IGMP Snooping IGMP Snooping Enable or disable the IGMP protocol.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 49 Static Filtering IP Address Assign a multicast group IP address in the range 224.0.0.0 to 239.255.255.255. Member Ports Select the port checkbox to include the port as a member in the specified multicast group IP address.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual LLDP Interval Set the interval (in seconds) for advertising the switch information to other nodes. Sync Time Enables or disables switch clock synchronization using LLDP. Apply Click to apply the settings. LLDP Neighbors The LLDP Neighbors page displays information about the port neighbors discovered using the LLDP protocol.
VLAN Configuration To configure VLAN, choose Configure-->VLAN-->VLAN Configuration. The 2080E-T Switch supports two VLAN modes—802.1Q (tagged-based) VLAN, and port-based VLAN. These modes are described on the following pages. By default, VLAN operation is disabled.
Page 53
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 802.1Q VLAN Mode—If you choose 802.1Q VLAN mode (Figure 54), you can see the link type, untagged VID, and tagged VID information of each port. Figure 54 VLAN Configuration - 802.1Q VLAN Operation Mode Select the VLAN operation mode, or disable VLAN.
Page 54
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual • IQ Trunk Link—This link type only supports multiple tagged VIDs. The IQ trunk link is a segment that provides the link path for one or more VLAN-aware devices (switches). A trunk port, connected to the trunk link, has an understanding of tagged frame, which is used for communication among VLANs across switches.
Page 55
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Based VLAN Mode—Port Based VLAN mode provides a simple way to create a VLAN. To create a new port based VLAN, first choose “Port Based” in the Operation Mode field (see Figure 55), and then click Add. The screen now looks like Figure 56.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Operation Mode Select the VLAN operation mode or disable VLAN. The following fields appear when you choose Port Based VLAN mode. Group Name Assign a name to the VLAN. VLAN ID Assign an identifier to the VLAN.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual QoS Mode Select from the following modes, or select “Disable” to turn off QoS. • Port Based—The output priority is determined by the ingress port. • COS Only—The output priority is determined by COS (Class of Service) only.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 60 COS Mapping to Queue COS Priority Each COS has four priority levels to choose from: High, Middle, Low, Lowest. COS Port Default Assign a default priority value to each port. A default priority is considered and determined by the ingress port when an ingress packet has no VLAN tag.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual DSCP priority The system provides 0 63 DSCP priority levels. Each level has four priority types: – High, Middle, Low, and Lowest. When an IP packet is received, the system will check the DSCP level value in the packet and grant it the appropriate priority.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 63 IP Source Guard - Configuration IP Security Mode Enable or disable IP security. When security is enabled, the fields on this page become active. Enable Web When this checkbox is selected, any device whose IP address matches one of the Management 10 IP addresses in the Security IP1...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 64 IP Source Guard - Static Table Security IP 1–10 Enter the IP addresses that will be allowed to access and manage the switch through the HTTP/Telnet service. Apply Click to apply the settings.
Page 62
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Figure 65 802.1X Radius - Configuration IEEE 802.1x Protocol Enable or disable 802.1x protocol. When enabled, the configuration parameters become available. Radius Server IP Assign the RADIUS server IP address. Server Port Set the UDP destination port for authentication requests to the specified RADIUS server.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 802.1X/Radius Port Setting You can configure the 802.1x authentication state for each port. To configure the port settings, choose Security-->802.1x/Radius-->Port Settings. Figure 66 802.1X Radius - Port Setting Port Authorization You can choose from the following authorization states: Mode • Reject—The specified port is required to be held in the unauthorized state.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.6.3 MAC Filtering To block an unauthorized MAC address by switch, choose Security-->MAC Filtering. The MAC blacklist shows the list of MAC addresses that are currently blocked. Figure 68 MAC Filtering MAC Address Enter a MAC address that you want add or delete from the MAC blacklist.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual MAC Address Enter a MAC address that you want add or delete from the Port Security List. Addresses on this list will be allowed access to the port. Port No. Select a port number.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.4 Firmware Upgrade The firmware upgrade software image for the 2080E-T Switch can be obtained by contacting a Sales Representative. To upgrade the firmware from a TFTP server or a website, choose Maintenance-->Firmware Upgrade.
To export a configuration file to a TFTP server, enter the TFTP server IP address and the backup file name, and then click Backup in the upper part of the Export tab. To export a configuration file to a local computer connected to the 2080E-T Switch, click Backup in the bottom part of the Export tab.
Page 68
Restore in the upper part of the Import tab. To import a configuration file that was exported to a local computer connected to the 2080E-T Switch, use the Browse button to locate the backup file, and then click Restore in the bottom part of the Import tab.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual 6.7.6 Diagnostics Ping To ping other network devices, choose Maintenance-->Diagnostics-->Ping, enter the IP address you want to ping, and then click Active. Figure 77 Diagnostics - Ping 6.8 Troubleshooting Follow these steps to troubleshoot switch problems.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual a - rJ-45 pIN aSSIGNMENT ppENDIx The UTP/STP ports will automatically detect fast Ethernet (10Base-T/100Base-TXconnections). Auto MDI/MDIX means that the switch can connect to another switch or workstation without changing straight-through or crossover cabling.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual B - COMMaND SETS ppENDIx This appendix describes the command sets for the 2080E-T Managed Ethernet Switch. The commands are associated with a user level, described in the following key. E = User EXEC...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example 8021x misc Use the 802.1x misc server timeout switch>enable servertimeout global configuration command to set switch#configure the server timeout. switch(config)#8021x misc [Seconds] servertimeout 20 8021x misc maxrequest Use the 802.1x misc max request...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Defaults/Example tftp Get configuration from TFTP server. switch>enable Need to specify the IP address of the switch#configure [server IP] TFTP server and the file name of the switch(config)#tftp 192.168.1.120 image.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example no ip dhcp Disable DHCP client function of switch>enable switch. switch#configure switch(config)#no ip dhcp LLDP Commands CLI Commands Level Description Example lldp enable Enable LLDP function. switch>enable...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Control Commands CLI Commands Level Description Example interface fastEthernet Choose the port for modification. switch>enable switch#configure [Portid] switch(config)#interface fastEthernet 2 state Use the state interface configuration switch>enable command to specify the state mode...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Port Monitoring Commands CLI Commands Level Description Example monitor destination Configure destination port of monitor. switch>enable switch#configure [RX|TX|Both] switch(config)#interface fastEthernet 2 switch(config-if)#monitor destination monitor source Configure source port of monitor. switch>enable switch#configure...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example no accounting Clear interface accounting switch>enable information. switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#no accounting Port Status Command CLI Commands Level Description Example show interface status Show interface actual status.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Rate Limit Commands CLI Commands Level Description Example ratelimit type all Set interface ingress limit frame type switch>enable to “accept all frame.” switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#ratelimit type all ratelimit type broadcast- Set interface ingress limit frame type switch>enable...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example snmp trap server Configure SNMP server host switch>enable [IP address] information and community string. switch#configure switch(config)#snmp trap server community 192.168.1.120 community public trap- [Community-string] version v2c trap-version...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example sntp daylight-offset Set offset of daylight saving time. switch>enable If SNTP function is inactive, this switch#configure [Minute] command cannot be applied. switch(config)#sntp daylight-offset 60 show sntp Show SNTP information.
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual System Warning Commands CLI Commands Level Description Example syslog mode Specified the log mode. switch>enable switch#configure [client|server|both] switch(config)# syslog mode both syslog ip Set system log server IP address. switch>enable switch#configure [IP address] switch(config)# syslog ip 192.168.1.100...
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example aggregator group Assign a static trunk group. switch>enable switch#configure [GroupID] [Port-list] [GroupID]: 1 – switch(config)#aggregator group 1 2-4 nolacp [Port-list]: Member port list. This nolacp parameter can be a port range (for...
Page 89
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example vlan port-based grpname Add new port based VALN. switch>enable [Group Name] switch#vlan database switch(vlan)#vlan port-based grpname grpid test grpid 2 port 2-4 [GroupID] port switch(vlan)#vlan port-based grpname...
Page 90
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example vlan 8021q port Assign a qinq link for VLAN by port. If switch>enable [PortNumber] the port belongs to a trunk group, this switch#vlan database command cannot be applied.
Page 91
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual C - GLOSSarY ppENDIx Term Definition American wire gauge (AWG), also known as the Brown & Sharpe wire gauge, is a standardized wire gauge system used predominantly in the United States and Canada for the diameters of round, solid, nonferrous, electrically conducting wire.
Page 92
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Term Definition IP Address A 32-bit number that identifies each sender or receiver of information that is sent across the Internet. An IP address has two parts: an identifier of a particular network on the Internet and an identifier of the particular device (which can be a server or a workstation) within that network.
Page 93
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Term Definition SNMP Trap SNMP traps are notifications or messages sent by a networked device to a management system. The messages are sent over the UDP protocol. The SNMP trap includes the IP address of the sender, the generic ID, specific ID, OID and corresponding value.
Page 94
Cooper Bussmann 2080E-T Managed Ethernet Switch User Manual Notes www.cooperbussmann.com/wirelessresources Rev Version 1.0...