EWC Controls Ultra-Zone S2000 Installation Instructions & Owner's Manual

Electronic steam unit - power humidifier

Advertisement

Installation
Instructions &
Owner's Manual
FOR GAS OR OIL FORCED AIR FURNACES, HEAT PUMPS AND ELECTRIC FURNACES
The Ultra-Zone Residential Power Humidifier you have purchased
has been designed to be simple to Install, Operate and Maintain.
Read this manual before you install the Humidifier.
TEMPERATURE PROBE
Parts included in the Steam Humidifier package are:
1. Self Piercing Saddle Valve
2. Installation Instructions and Owners Manual
3. Mounting Templates x2
4. Installation Hardware package
5. Insulation and tape
6. Automatic Drain Assembly
7. Humidistat - Model #062000 or 072000
8. 1/2" I.D. Drain Hose-8 FT.
9. Anode #Z100
ELECTRONIC STEAM UNIT - POWER HUMIDIFIER
®
MODELS S2000 AND S2020
WATER INLET
WATER LEVEL
PROBE
HEATER
FIG. 1
©
Copyright
1999-2009 EWC Controls All Rights Reserved.
Familiarizing yourself with the items listed in Figures 1
and 2 will assist you in installing and maintaining your
Steam Power Humidifier. This product should be installed
according to local and national codes and standards.
WATER PAN
TANK BAFFLE
WATER INLET
FOR DRAIN
VALVE DETAILS
See Page 12
E w
c
C O
N T
R O
L S
, I
N C
S t e
.
a m
M o
H u
®
d e
m i
2 . 0
l S
d i f
K W
2 0
i e r
2 0
S u
2 4
it a
b le
0 V
3 8
fo r
o lt
5 H
R e
s id
8 . 3
ig h
e n
s e
w a
ri a
ti a
A m
l n
y 3
l U
u m
3 ,
s e
p s
b e
E n
O n
r
g li s
ly
h to
U .S
w n
. P
, N
F or
A T
R ep
E N
J 0
09
la ce
T N
7 7
02
m en
1A
U M
2 6
01
t P
B E
C
U
18
ar ts
R 5
C al
l (8
7 5
L
00
8 0
) 44
®
U S
1 8
6- 31
10
L IS
T E
D 1
4 1
V
MANUAL WATER DRAIN
Options and additional parts recommended:
1. Water Hammer Arrester #WH 100
2. Anode #Z100
3. Decorative Under Duct Cover # SC100
4. Gasket Material to seal flanges (field provided)
5. Model APD Current Sensing Switch, Sail Switch or
other Airflow Proving Device.
6. WFA-195 Water Filter Assembly
1
This symbol on
the product means
the product is
listed by
Underwriters
Laboratories, Inc.
P O
W E
R
T h
e rm
is to
H e
r
a te
r
W a
te r
B L
O W
E R
H E
A T
E R
F IL
L
D R
A IN
BLOWER
INTERLOCK &
HUMIDISTAT CONN.
OVERFLOW
STATUS LIGHTS
AUTO DRAIN CONN.
"T" ADAPTER
P/N 090375A0227 Rev. L
FIG. 2
04/28/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra-Zone S2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for EWC Controls Ultra-Zone S2000

  • Page 1: Installation Instructions

    6. Automatic Drain Assembly other Airflow Proving Device. 7. Humidistat - Model #062000 or 072000 6. WFA-195 Water Filter Assembly 8. 1/2” I.D. Drain Hose-8 FT. 9. Anode #Z100 P/N 090375A0227 Rev. L 04/28/09 © Copyright 1999-2009 EWC Controls All Rights Reserved.
  • Page 2: Simplified Installation Instructions

    SIMPLIFIED INSTALLATION INSTRUCTIONS 1. Insulate the water reservoir. See figure 3. 6. Flush and connect the water line. 2. Select the mounting location on the duct and tape 7. Connect the drain line. on the mounting template. 8. Make 24 VAC electrical connections to achieve fan 3.
  • Page 3 8. STEAM OPERATION - Required Criteria 6. WATER SUPPLY - Required Criteria A. WATER SUPPLY USING THE SADDLE VALVE Because of the high output of this Humidifier, it must not be operated without the blower operating. The steam FURNISHED WITH UNIT. Important! See page 14. humidifier is designed to be "Dominant"...
  • Page 4 CONTROL WIRING SOLUTIONS FOR VARIOUS HVAC SYSTEMS Additional diagram shown on page 7. FIG. 6 Heat Only System and Conventional Heat & Cool System and FIG. 7 Steam Humidifier with standard Steam Humidifier with Ultra-Zone 072000 Humidistat dry contact Humidistat S2000 &...
  • Page 5: Dimensional Data

    Figure 12. Figure 12 reflects the basic dimensions of the Ultra-Zone S2000 or S2020 Steam Humidifier. This data is useful in determining the room needed to install the unit in a certain location. The data can also be used to determine the minimum duct size the Steam Humidifier can be inserted into.
  • Page 6 On under-duct applications, it may be necessary to insert an Air-Ramp in the duct to induce the steam out of the tank. Contact Technical Support for assistance. © Copyright 1999-2009 EWC Controls All Rights Reserved.
  • Page 7: Relative Humidity Chart

    “enhanced” latent effect operations of your variable speed HVAC system. If you do not want this to happen, you should consider installing a different type of whole house humidifier that does not require dominance over the HVAC fan and full CFM capacities while operating. Variations on this diagram are available. Contact EWC Controls Technical Support Hotline. ©...
  • Page 8 INITIAL START-UP * SEQUENCE OF OPERATION * SERVICE “LED” INDICATORS D. BLOWER: When the water in the reservoir reaches 11. START -UP & OPERATING SEQUENCE approximately 170 deg. F. the "BLOWER" LED will be illuminated and the interlock wiring should turn the Once the Steam Humidifier has been installed and the system blower on.
  • Page 9 13. MAINTENANCE/SPRING SHUTDOWN Rinse out the reservoir. Be careful to keep water off of the wiring compartment and the front cover of the humidifier. Proper maintenance and removal of mineral deposits is still Allow the unit to dry thoroughly before using! required on your steam humidifier in order to optimize performance.
  • Page 10 SERVICE INDICATORS 5.The water valve may be defective and must be replaced The green "Power" light does not blink off and on. See replacement parts. 1. The S2000 is not connected to an active 120 6. The drain valve is unplugged or defective. VAC 15 Amp power source.
  • Page 11 F I L a ll (8 0 ® 6 -3 L IS Figure 17. A I N 385 Highway 33 Englishtown, NJ 07726 www.ewccontrols.com e-mail: Info@ewccontrols.com Tel. (800) 446-3110 Fax: (732) 446-5362 © Copyright 1999-2009 EWC Controls All Rights Reserved.
  • Page 12 OVERFLOW TUBE, Figure 18 .50 ID x 6" LG. SOLENOID VALVE, 24/60 VAC "T" ADAPTER, 1/4" NPT BLACK WIRES 18GA. X 18" LONG DRAIN COCK VALVE JUMPER WIRE, 20GA. X 1.50" LONG MOLEX PLUG BARBED TEE, 1/4-18 NPT TO ½" 385 Highway 33 Englishtown, NJ 07726 www.ewccontrols.com...
  • Page 13 TECHNICAL BULLETIN ® Model 072000 Smart Digital Humidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. E December 5, 2006 Copyright © 2004-2006, EWC Controls Inc., All Rights Reserved Your new Steam Humidifier may include this Package includes: control. The...
  • Page 14: Application Note

    Z100 from falling down into the tank. The Z100 is just the latest innovation in the Ultra-Zone Steam Humidifier line as we continue in our pursuit of Excellence Without Compromise. EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-635-8646 E-Mail- info@ewccontrols.com ©...
  • Page 15 Excellence Without Compromise. S2000/S2020 STEAM HUMIDIFIER SC100 - PART # 2009 DECORATIVE COVER P/N 090376A0151 REV. A Copyright 2003 © EWC Controls Inc., All Rights Reserved EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-635-8646 E-Mail- info@ewccontrols.com...
  • Page 16 Date of Service:__________Service Performed:________________________________________________________ Date of Service:__________Service Performed:________________________________________________________ Date of Service:__________Service Performed:________________________________________________________ COMMENTS:___________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 732-446-3110 FAX 732-446-5362 © Copyright 1999-2009 EWC Controls All Rights Reserved.

This manual is also suitable for:

Ultra-zone s2020

Table of Contents

Save PDF