Digi-Tron ULPH Operation Manual

Human scale

Advertisement

Quick Links

Human Scale
Operation Manual
April 2007
Digi-Tron
Specialists in Industrial Weighing
www.digitronbalancas.com.br
Index
1. Introduction.........3
2. Installation............4
Verifying electricity....................4
Plugging in the scale.......................5
3. Operation...................6
Zeroing...............6
Automatic zero...........6
Manual zero....................6
Weighing...............6
Setting the clock..................7
RS 232 Serial Port.............7
Label printer..............8
4. Troubleshooting.......................10
Error Zero........................10
Error Five.................10
Error Six....................10
Error Seven..........................10
Error Eight.......................11
Low battery..........................11
Excess Weight...................11
Underweight.................11
Blinking display...................11
Display with some segments dimly lit.......................12
Scale fails to turn on.........................12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULPH and is the answer not in the manual?

Questions and answers

Summary of Contents for Digi-Tron ULPH

  • Page 1: Table Of Contents

    Human Scale Operation Manual April 2007 Digi-Tron Specialists in Industrial Weighing www.digitronbalancas.com.br Index 1. Introduction………3 2. Installation………...4 Choosing an adequate location………….4 Verifying electricity………………..4 Verifying connections and cables………..5 Plugging in the scale…………………..5 3. Operation……………….6 Keypad functions……6 Zeroing……………6 Automatic zero………..6 Manual zero………………..6 Weighing……………6...
  • Page 2: Introduction

    1. Introduction Dear User, This manual contains instructions on how to install and operate the Human Scale model ULPH, designed with technology and quality standards set by Digi-Tron, a company specialized in precision instruments. Its proper functioning, however, depends also on the treatment and care given by the user, as much in the installation as in its daily use.
  • Page 3: Verifying Electricity

    Plug in the scale and then turn the on/off (liga/desliga) key located in the back of the indicator. The word “digi-tron” will appear on the screen and the scale’s CPU version followed by a countdown. During the countdown, verify that all of the numbers light up completely.
  • Page 4: Operation

    3. Operation 3.1 Keypad functions Turn display on/off Set tare Set zero Print weight I (held for 2 Print total net seconds) weight 3.2 Zeroing Bias in zeroing occurs due to variations in temperature, residue on the platform, impact incurred to the weighing platform, or the scale being uneven. If there is nothing on the platform and the zero indicators is off, it is necessary to zero the scale.
  • Page 5: Setting The Clock

    3.6 Setting the Clock The clock displays the time that will be printed on the tickets. Pressing the L and I buttons in sequence will access the clock configuration mode. Time Date Press Z to choose between setting the hour, date, day of the week, and year.
  • Page 6: Rs 232 Serial Port

    3.7 RS 232 Serial Port The scale has a RS232 serial communication port. It is used to connect the scale to a computer or serial printer to print labels. 3.7.1 Communication with a computer- Terminal Mode This option allows the scale to be connected to a PC so that with the use of management software it is possible to control the weighing and print reports and labels.
  • Page 7: Troubleshooting

    - To verify with what printer model your scale is compatible, check the code that appears on the display when it is turned on. - When the scale is turned on, the display will show the word `Digi-Tron´ and then the model and version code will appear.
  • Page 8: Error Five

    Breakdown in the cargo cells due to overload (excess weight or impact incurred to the weighing platform). If the error continues, seek technical assistance. 4.2 Error Five Description of error: Overload on the scale beyond the cargo cell’s capacity. This error only appears during scale operation.
  • Page 9: Underweight

    Description of error: When the battery is low, this error message is shown every two minutes. Recharge the battery immediately so that there is no damage to the battery or errors in the weight readings. 4.7 Overload Description of Error: The weight is over 5 unit divisions of the Maximum Load.
  • Page 10: Scale Turns Off After Weighing Or Counting

    If it turns on with the display brightly lit, there is too much power. Seek technical assistance. If it lights up normally but it is not able to finish the start-up, there is not enough power. Check the battery and recharge if necessary. 4.12 The scale turns off after weighing or counting Symptom: The scale turns off after the start-up's...