1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
Indoor unit
Connecting wiring
3G1.0mm
HSU-09C03/VA(ZXF)
HSU-12C03/VA(ZXF)
Indoor unit
Connecting wiring
3G2.5mm
HSU-22C03/V(ZXF)
HSU-22C03/V(ZF)
HSU-24C03/V(ZXF)
HSU-24C03/V(ZF)
Power cable:
2
-mod 09-12:
3G1.0mm
2
-mod 18:
3G1.5mm
2
-mod 22-24:
3G2.5mm
5.Installation instruction on the indoor part of the fresh air device
1.Two ways for the installation of indoor part, as illustrated:
Way One:(For all the models)
In the guard ring, connect outlet joint with the fresh air tube .
Way Two(Only for the models of 09,12):
Insert the joint of water collecting pan into the fresh air tube, then connect the other end of joint
with mesh enclosure of water collecting pan.
Guard ring
2.Another way for the models of 18,22 ,24,as illustrated:
Way One (right direction): Take off the lid for right piping pipe,put the Outlet joint into the lid,then put the fresh air tube
Way Two (left direction): Take off the lid for leftt piping pipe,put the Outlet joint into the lid,then put the fresh air tube
Outlet joint
Lid for under piping
Fix with adhesive tape
Change for fresh air tube
Indoor unit
Indoor unit
Outdoor unit
2
Connecting wiring
HSU-09H03/VA(ZXF)
HSU-12H03/VA(ZXF)
2
Outdoor unit
Outlet joint
(in guard ring)
Fresh air tube
Installation way One
into the outlet jont.
into the outlet jont.
Drain hose
Indoor unit
Outdoor unit
2
5G1.0mm
Indoor unit
HSU-12H03/VB(ZXF)
HSU-12H03/V(ZXF)
HSU-18H03/V(ZXF)
Connecting wiring
HSU-22H03/V(ZXF)
HSU-22H03/V(ZF)
-mod 12: 5G1.0mm
HSU-24H03/V(ZXF)
-mod 18-22-24:
HSU-24H03/V(ZF)
HSU-24HK0307
3G2.5mm
HSU-24HD0307
Installation way Two
Lid for left piping
5
Outdoor unit
Connecting wiring
2
3G2.5mm
HSU-18C03/V(ZXF)
Outdoor unit
2
2
2
+2x0.75mm
Joint of water
collecting pan Fresh air tube
For the units with
fresh air function
To indoor unit
To outdoor fresh air motor
The connecting method of
fresh air box signal wire