Download Print this page

Before Using This Air Tool; Operating Instructions; Troubleshooting - Eagle EGA300 Owner's Manual

6” orbital palm sander

Advertisement

BEFORE USING THIS AIR TOOL

To ensure long life be sure to oil the tool daily. Pour 4 drops of Eagle air tool (SEA 20 non
detergent) oil into the air inlet, and then run the tool for a few seconds to clean.
If tool is an impact wrench fitted with a "Zirc" grease fitting:
The hammer mechanism of this tool also needs to be greased from time to time (depending
on usage). The tool is equipped with grease fitting for this purpose; use this connection to
re-grease the tool using Eagle impact wrench grease.
PLEASE USE EAGLE SEA 20 NON DETERGENT OIL
Regulate pad speed with the regulator knob. Start the sander OFF the sanding surface. Set
the sander on the surface gently and evenly and start the work. Let the sander do the work.
The weight of the sander will provide sufficient sanding. Applying pressure to the sander
will only slow the speed of the pad and reduce sanding efficiency. This will also overload
the motor and cause premature weight on the tool and void the warranty.
Start the sander off the work, set it down on the work evenly and move it slowly back and
forth in wide overlapping areas, when finished sanding, lift it off the work before stopping
motor.
Start with a paper coarse enough to remove high spots and rough surface, continue using
progressively finer grit to obtain desired finish.
SYMPTOMS
Air tool does not
run or runs slow.
IMPACT WRENCH
does not impact or
impacts slowly.
Wear hearing protection.
Wear eye protection.
Wear respiratory protection.

OPERATING INSTRUCTIONS

TROUBLESHOOTING

CAUSE
Lack of lubrication.
Dirt in tool.
Insufficient air pressure.
Rotor blades worn or motor
bearing worn or dirty.
See causes (above).
Broken or worn impact
mechanism.
REMEDY
Lubricate as per instructions.
Clean with mixture of 50/50 tool
oil/solvent. Lubricate after cleaning.
Check regulator and air supply for
leaks. Check compressor to make
sure it operates at correct pressure.
Make sure air hose is properly sized
and that multiple hoses are not
connected to same outlet. Check air
hose for leaks and repair.
Replace blades, inspect clean or
replace bearing.
See remedies (above).
Inspect and repair as required.
Read the instruction manual
5