Mac victor 2.0 - 2/3kva rating wall mounted, centralized, isolated power supply and battery backup system

Advertisement

Quick Links

Mac Victor 2.0
Installation and Operating Manual
MVP-2KS / MVP-2KL (2 kVA rating)
MVP-3KL (3 kVA rating)
Mac Victor 2.0
The
is an ultra high quality power system that provides centralized and wall mounted
Mac Victor 2.0
The
is an ultra high quality power system that provides a centralized and wall mounted source
source for mission critical power to supply the most vital electronic loads distributed throughout a
for mission critical power to supply the most vital electronic loads distributed throughout a facility.
Mac Victor 2.0
facility. The
provides both hard wired connectivity to remotely located Isolated
Mac Victor 2.0
The
provides both hard wired connectivity to remotely located Isolated Ground (IG) network
Ground (IG) network power receptacles along with plug and receptacle connectivity for the Uninterruptible
power receptacles along with plug and receptacle connectivity for the Uninterruptible Power Supply (UPS).
Power Supply (UPS).
®
®
The mission of Mac Victor
is to Expand Your Power
by enhancing the return on investment
of your Critical Electronic Systems
Mac Victor
and Expand Your Power
are registered U.S. trademarks of Mac Victor Power, LLC
®
®
Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC.
Page 1 of 23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MVP-2KS and is the answer not in the manual?

Questions and answers

Summary of Contents for Mac Victor MVP-2KS

  • Page 1 Critical Electronic Systems Mac Victor and Expand Your Power are registered U.S. trademarks of Mac Victor Power, LLC ® ® Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 1 of 23...
  • Page 2: Table Of Contents

    6.6 Mac Victor 2.0 Replacement Parts 7 SPECIFICATIONS ………………………………………………………………………………………………………… 22 7.1 Mac Victor 2.0 Specifications 7.2 UPS Specifications and Compatible UPS Models Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 2 of 23...
  • Page 3: Important Safety Instructions

    While every effort has been made to ensure the completeness and accuracy of this manual, Mac Victor Power, LLC and THOR SYSTEMS, Inc. accept no responsibility or liability for any loss or damage resulting from the use of the information contained in this document.
  • Page 4: Ups Batteries

    Store the Mac Victor 2.0 units in a dry location. Storage temperature must be within a range of -15ºC to 50ºC (5ºF to 122ºF) Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 4 of 23...
  • Page 5: Product Overview

    The Mac Victor 2.0 therefore provides a centralized system with both “clean” isolated ground power and battery backup power for critical electronic networks in addition to many other operational and maintenance benefits. Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 5 of 23...
  • Page 6: System Benefits

    • When the RPO switch is deactivated input power feeding the isolation transformer is reconnected by the relay which restores power to the IG receptacles and equipment Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 6 of 23...
  • Page 7: Component Diagram

    Uninterruptible Power Supplies (UPS) that mount on top of the Mac Victor 2.0 base units must be ordered separately and must be “Mac Victor 2.0 Compatible UPS”. See Section 7.2 for a list of Compatible UPS models. Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 7 of 23...
  • Page 8: Options / Accessories

    3 – OPTIONS / ACCESSORIES 3.1 Mac Victor 2.0 Options These Mac Victor 2.0 optional features are available with the MVP-2KS, MVP-2KL, and MVP-3KL base units. See complete part number listing in Section 2.6. -IG Suffix (Isolated Ground receptacle option) Integrated Isolated Ground Receptacles Option (-IG suffix) –...
  • Page 9: Installation

    The Mac Victor 2.0 Typical Elevation below provides a conceptual diagram of a typical wall mounted elevation that shows the overall enclosure dimensions and typical input and output power wiring. Figure 4.1 – Mac Victor 2.0 Elevation Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 9 of 23...
  • Page 10: Mounting Instructions

    At this point, the Mac Victor 2.0 should hang freely on the wall. 10. Check the 2 lag bolts to insure they are fully and securely tightened. Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 10 of 23...
  • Page 11: Wiring Diagram - Mac Victor

    See Section 4.6 for the wiring diagram for the Remote Power Off function See Section 4.7 for the wiring diagram for the Input / Output Power Status function Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 11 of 23...
  • Page 12: Wiring Diagram - Remote Power Off

    15 to 16 are open Relay TB-2 Relay TB-1 Relay Specifications (TB-1 & TB-2): Maximum contact rating (per relay) 1/10 amp at 120Vac Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 12 of 23...
  • Page 13: Th Circuit Ig Outlet And Optional Remote Off

    (R2) and turns off Circuit #5 IG outlets. Restoration of 120Vac power closes relay (R2) and turns on Circuit #5 IG outlets. Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 13 of 23...
  • Page 14: Startup / Operation

    11. Plug in the selected electronic equipment to the remote IG receptacles and the optional integrated IG outlets. 12. Insert the Safety Outlet Protector Plugs (included) on all remaining open outlets on the IG receptacles. Figure 5.1 Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 14 of 23...
  • Page 15: Installation And Strapping Of The Ups

    Maximum UPS width = 8.6 inches Maximum UPS weight = 95 lbs. Mac Victor 2.0 (Right hand side view) Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 15 of 23...
  • Page 16: Power Up Of The Ups

    Maximum UPS width = 8.6 inches Maximum UPS weight = 95 lbs. Mac Victor 2.0 (Right hand side view) Plug Assy MV Power Receptacle Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 16 of 23...
  • Page 17: Surge Monitoring Operation

    POWER ON (green LED) is OFF indicates loss of output power or the output Surge & Filter Board Assembly Fuse (F1) must be replaced (THOR#: 0603-0004-01) Figure 5.4 Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 17 of 23...
  • Page 18: Maintenance/Troubleshooting

    * Indication that Mac Victor plug cable is not plugged into UPS * Switch to “Normal” after the UPS power is restored Figure 6.3 “OFF” “ON” Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 18 of 23...
  • Page 19: Input Spd Alarm / Output Fuse Indication

    Circuit Breaker and integrated Isolated Ground (IG) Receptacles Standard Output Circuit Breakers (quantity of 4) Standard Input Circuit Breakers (quantity of 1) Figure 6.5 Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 19 of 23...
  • Page 20: Ups (Uninterruptible Power Supply)

    (See Section 6.6) Output status Relay (TB-1) Fuse F-2 is bad Replace Fuse F-2 is not operating (See Section 6.6) (See Section 6.6) Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 20 of 23...
  • Page 21: Mac Victor 2.0 Replacement Parts

    TB-2 Relay Output Power Input Power Replacement Fuses F-2 & F-3 (relay contacts) Class 2AG - fast acting / 1/10 amp THOR#: 0603-0100-02 Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 21 of 23...
  • Page 22: Specifications

    UPS External Battery cabinets are not permitted on the Mac Victor 2.0 Shelf and must be located separately Maximum UPS width = 8.6 inches / Maximum UPS weight = 95 lbs. Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 22 of 23...
  • Page 23 U.S. trademarks of Mac Victor Power, LLC ® ® Manufactured by: THOR SYSTEMS, INC. www.ThorSystems.US 804-355-1100 804-355-8900 fax 3621 Saunders Avenue Richmond, VA 23227-4354 Mac Victor 2.0 Installation Operation Manual 042408.pdf - © 2008 Mac Victor Power, LLC. Page 23 of 23...

This manual is also suitable for:

Mvp-2klMvp-3kMvp-3kl

Table of Contents