Summary of Contents for National Vacuum Equipment 5314

  • Page 1: Operating Instructions

    National Vacuum Equipment Owner’s Manual & Operating Instructions Model 5314 Blower Visit our web site to download brochures and other MADE IN USA technical information.
  • Page 2 | 800.253.5500 2 | 5314 Blower...
  • Page 3 Owner’s Record Date of Purchase: _________________________ Purchased from: __________________________ Serial Number: ____________________________ © 2013 National Vacuum Equipment, Inc. Revision A No part of this manual may be reproduced without the written permission of National Vacuum Equipment, Inc. www.natvac.com | 800.253.5500...
  • Page 4: Table Of Contents

    Contents Introduction ....................6 About National Vacuum Equipment, Inc...........6 Our History ....................6 Limited Warranty ..................7 Warranty ....................7 Warranty Procedures ................8 Overview .......................9 General Blower Operation ................9 General Blower Construction ..............10 Location of Serial Number ..............10 Specifications ....................11 Operating Environment ................11 Operating Limits ..................11...
  • Page 5 Operating ....................23 Stopping the Blower................23 Cold Weather Operation .................23 Maintenance ....................24 MAINTENANCE SCHEDULE ..............24 Oil Capacities and Recommendations .............25 Rebuilding ....................26 Cleanout Procedure If Flooded ...............27 Parts Diagram ..................28 Parts List ....................29 Troubleshooting ..................30 www.natvac.com | 800.253.5500 5314 Blower | 5...
  • Page 6: Introduction

    Our History National Vacuum Equipment, Inc. was founded in 1980 by Bruce Luoma. The Company started as a retailer of vacuum pumps. Soon after it started, the Company secured the rights to exclusive distribution of the Battioni vacuum pumps in North America.
  • Page 7: Limited Warranty

    6. Manufacturer’s liability shall not be enforceable for any product until National Vacuum Equipment, Inc. has been paid in full for such product. 7. Except to the extent expressly stated herein, manufacturer’s liability for incidental and consequential damage is hereby excluded to the full extent permitted by law.
  • Page 8: Warranty Procedures

    Product must be returned to NVE freight prepaid in the most eco- nomical way. Credit will be issued for material found to be defective upon our inspection, based upon prices at the time of purchase. www.natvac.com | 800.253.5500 8 | 5314 Blower...
  • Page 9: Overview

    The airflow capacity of the machine (in ACFM) is nearly proportional to the speed of the machine and is nearly constant with changes in inlet or outlet pressures. www.natvac.com | 800.253.5500 5314 Blower | 9...
  • Page 10: General Blower Construction

    Each blower should have a brass colored tag with an embossed serial num- ber. In addition, the serial number and blower direction as assembled at the factory are stamped into the top of the housing as shown: www.natvac.com | 800.253.5500 10 | 5314 Blower...
  • Page 11: Specifications

    SPECIFICATIONS Operating Environment The 5314 blower is designed to move atmospheric air. Do not use to move explosive or corrosive gasses or operate the blower in an area with explosive gases. Any materials in the intake air must be filtered and separated from the air by means of an intake filter, moisture trap and/or a cyclonic filter.
  • Page 12: Performance (Reference Only)

    34.2 54.6 64.8 75.0 85.2 95.4 72.9 3600 ACFM 1587 1320 1179 1087 B.O. 1252 ACFM - Actual CFM generated on the vacuum or pressure side of the machine B.O. - Blanked Off www.natvac.com | 800.253.5500 12 | 5314 Blower...
  • Page 13: Dimensions

    It is recommended the operator monitor the blower while running and listen for resonances (increased levels of noise) that may occur at certain RPM’s and operate the blower at speeds above or below the resonance speeds to reduce excess noise. www.natvac.com | 800.253.5500 5314 Blower | 13...
  • Page 14: Limitations On Use

    Operating in excess of the Seizure of Blower, damage to Reduce the vacuum or pres- specified temperature rise blower and ejection of parts sure level to bring within across the blower limits. www.natvac.com | 800.253.5500 14 | 5314 Blower...
  • Page 15: Storage

    Keep all intake, exhaust and ballast ports covered to prevent accidental ingestion of material into the blower. Handling Use an appropriately sized lift strap for lifting the blower. Thread two 3/4” eye bolts into unused mounting feet as shown. Model Weight (Lbs) 5314 www.natvac.com | 800.253.5500 5314 Blower | 15...
  • Page 16: Preservation

    In addition, remove the oil fill plug on drive oil tank and inspect the gear for absence of rust. Use a rust preventative oil with a flash point over 400°F Dispose of used rust preventative oil according to local regulations INSTALLATION Rotation and Airflow www.natvac.com | 800.253.5500 16 | 5314 Blower...
  • Page 17: Diesel Engine Precautions

    424-M500-14T M500A1412 Blower Jaw 424-225-187 L225X1 7/8 Spider (Urethane) 12417 LoveJoy Ring Drive Jaw 424-225-<BORE> L225X<BORE> Installation and Alignment Slide the couplers onto the blower shaft and prime mover shaft using appropriate tools. www.natvac.com | 800.253.5500 5314 Blower | 17...
  • Page 18: Belt Drive

    RPM. U-Joint operating angles on each end of a drive shaft should always be equal within 1° of each other to cancel an angle vibration. www.natvac.com | 800.253.5500 18 | 5314 Blower...
  • Page 19: Hydraulic Drive

    6” hose minimum. Be sure to locate the ballast inlet away from heat, debris and fluid sources as exposure to these may result in damage to the blower. www.natvac.com | 800.253.5500 5314 Blower | 19...
  • Page 20: Recommended Accessories

    (i.e. tank protection or overheat protection). We would recommend the use of a high quality vacuum relief valve such as Kunkle. www.natvac.com | 800.253.5500 20 | 5314 Blower...
  • Page 21: Check Valves

    Bag houses are typically used in systems where dry material is being pumped. Specification of a proper bag house depends on the frequency and type of dry material being pumped. Consult the factory for assistance in selecting a bag house. www.natvac.com | 800.253.5500 5314 Blower | 21...
  • Page 22: Operation

    Increase the vacuum level slowly until the rated level is reached. During the first 8 hours of operation, check that there are no vacuum leaks, oil leaks, vibrations or strange noises. www.natvac.com | 800.253.5500 22 | 5314 Blower...
  • Page 23: Operating

    Kerosene. Use the recommended oil for the operating temperatures. If temperatures are so cold that the blower cannot warm up, enclose the blower allowing for sufficient clearance from parts to prevent contact with hot or moving components. www.natvac.com | 800.253.5500 5314 Blower | 23...
  • Page 24: Maintenance

    Oil Change-Initial Oil Change-Normal 1000 Vacuum <1 in Hg FILTER Clogging Wear 2000 DRIVETRAIN Belt Tension 2000 Belt Change 15000 Oil Change-Initial RIGHT ANGLE Blower GEARBOX Shutdown Oil Change-Normal MOISTURE Drain Fluid TRAP/ SECONDARY www.natvac.com | 800.253.5500 24 | 5314 Blower...
  • Page 25: Oil Capacities And Recommendations

    4310 18 (.53) 8 (.24) 26 (.77) 18 (.53) 8 (.24) 26 (.77) 5314 13 (.38) 18 (.53) 31 (.92) 48 (1.42) 24 (.71) 72 (2.13) 1457 44 (1.30) 33 (.98) 77 (2.28) www.natvac.com | 800.253.5500 5314 Blower | 25...
  • Page 26: Rebuilding

    Dispose of used oil according to local regulations Rebuilding Rebuilding is beyond the scope of this owner’s manual and should be performed only by trained technicians. Consult an authorized distributor or NVE to arrange rebuilding of the blower. www.natvac.com | 800.253.5500 26 | 5314 Blower...
  • Page 27: Cleanout Procedure If Flooded

    Clean it out as best you can. Drain all fluids from the silencer and allow it to dry. 8. When everything is clean and dry, reassemble the manifold and silencers. Make sure flange bolts on the blower are tightened evenly. www.natvac.com | 800.253.5500 5314 Blower | 27...
  • Page 28: Parts Diagram

    | 800.253.5500 28 | 5314 Blower...
  • Page 29: Parts List

    5314 Blower Parts List ITEM PART NUMBER DESCRIPTION 150-001-5314 HOUSING BLOWER 5314 MACHINED 150-003-003 ENDPLATE 5314 DRIVE END MACH 150-003-004 ENDPLATE 5314 GEAR END MACH 150-005-5314-D ROTOR DRIVE 5314 150-005-5314-I ROTOR IDLER 5314 150-006-002 KEY .5"X.5"X2.5" 1018 BER 150-043-001 DOWEL HOLLOW 5/16" X 1/2"...
  • Page 30 CAD drawing - NO manua MBER DESCRIPTION All dimensions in inches O-RING 2-348 VITON This document may contai GASKET BALLAST MANIFOLD 5314 secret information whic BALLAST MANIFOLD LH 5314 property of National Vacuu information on this draw BALLAST MANIFOLD RH 5314...
  • Page 31: Parts List

    5314 Ballast Manifold Parts List ITEM PART NUMBER DESCRIPTION 120-064-021 O-RING 2-348 VITON 150-616-5314 GASKET BALLAST MANIFOLD 5314 150-650-012 BALLAST MANIFOLD LH 5314 150-650-013 BALLAST MANIFOLD RH 5314 150-650-014 BALLAST TEE 5314, MACH LW - 5/6” LOCK WASHER, 5/16” SHCS - 5/16-18 UNC X 1.25 SOCKET HEAD CAP SCREW - 5/16 UNC X 1.25...
  • Page 32: Troubleshooting

    D, E, F, H, K, U & V Blower is creating unusual noises or vibrations A, B, C, D, F, G,H, K, L, N, W & AC STOP THE BLOWER TO PREVENT DAMAGE www.natvac.com | 800.253.5500 32 | 5314 Blower...
  • Page 33 Four way valve not fully seated in Seat the 4-way valve. Clean if debris built up has proper position occurred. Faulty relief valve Replace relief valve Rotors timing is off Have blower rebuilt www.natvac.com | 800.253.5500 5314 Blower | 33...
  • Page 34 | 800.253.5500 34 | 5314 Blower...
  • Page 35 | 800.253.5500 5314 Blower | 35...
  • Page 36 National Vacuum Equipment, Inc. P.O. Box 685 Traverse City, MI 49685 USA 231.941.0215 Phone 231.941.2354 Fax www.natvac.com | 800.253.5500 36 | 5314 Blower...

Table of Contents