Temperature Controls

The maximum set temperature of the spa is
104°F (40°C) and the minimum set temperature is
80°F (27°C). The display will show the current
water temperature or, if the pump has not been run-
ning, two dashes. If the two dashes are displayed,
you must first start the pump by pressing the "Jets
1" pad. Wait until the water temperature is dis-
played (approximately 2 minutes).
The set temperature of your spa may easily be
increased or decreased at any time using the
"Temp" pad. Look at the LED display. Either the
actual temperature or 2 dashes will be displayed.
Press the "Temp" pad; the set temperature will be
displayed in the LCD window. The next touch of
the "Temp" pad will change the set temperature
either up or down 1°F. If you want to increase the
temperature and the display indicates the tempera-
ture was increased by 1°F, continue to press the
"Temp" pad until the desired set temperature is
reached.
If you want to decrease the set temperature and
the display indicates the temperature was increased
by 1°F, STOP. Wait a few seconds until the actual
temperature is displayed, then press the "Temp" pad
again. Press it again and the set temperature will
decrease by 1°F. Continue pressing the "Temp" pad
until the desired set temperature is reached.
If the spa is set in STANDARD mode or in a
filtration cycle, increasing the set temperature may
result in activating the heater. Likewise, decreasing
the set temperature may result in turning the heater
off. When the heater is operating, the LED heat
indicator will be lit.
Note:
Model 351 spas that are wired 120V/20A
will not heat when the pump is on in high
speed.
Note:
Spas that are wired for 240V/30A will not
heat when Pump #1 is on in high speed, or
when Pump #2 is operating.
Jets
Touch the "Jets 1" pad to activate the operation
of Pump 1. The sequence of the jet action is:
1 touch = Low Speed
2 touches = High Speed
3 touches = Off
Touch the "Jets 2" pad to activate the operation
of Pump 2. The sequence of the jet action is:
1 touch = High Speed
2 touches = Off
The low speed operation of Pump 1 is timed to
automatically turn off after four hours of operation.
The high speed operations of Pump 1 and Pump 2
are timed to automatically turn off after 15 minutes
of operation.
Note:
Pump 1 will automatically operate in low
speed whenever the spa is in a filtration
cycle or when it calls for heat. When this
automatic activation occurs, the low speed
operation of Pump 1 can not be turned off;
however, all other control functions can be
activated.

Light

Touch the "Light" pad to turn the internal spa
light on or off. The light will automatically turn off
after 1 hour of operation.
Operating Modes
Your Coleman Spa comes with three primary
operating modes.
Standard Mode maintains the water at the
desired set temperature. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least 2 minutes. The
LCD window will momentarily display "St" when
this mode is selected.
Economy Mode heats the water to the desired
set temperature ONLY during filter cycles. The
LCD window will display "Ec" when this mode is
selected and the temperature is not current. The
LCD window will alternate between "Ec" and the
temperature when the temperature is current.
Sleep Mode heats the spa to within 20°F
(11°C) of the set temperature only during filter
cycles. The LCD window will display "Sl" when
this mode is selected and the temperature is not cur-
rent. The LCD window will alternate between "Sl"
and the temperature when the temperature is cur-
rent.
Changing Modes
To change the operating mode, press the
18