Denver Concrete Vibrator An American Tradition 4E-180 Series High-Cycle Generator User Manual 1463 W. Alameda Ave., Denver, CO 80223 USA Phone 303-778-8832 / 800-392-6703 Toll Free / FAX 303-778-8682 www.denverconcretevibrator.com info@denverconcretevibrator.com...
IMPORTANT SAFETY INSTRUCTIONS Rules for safe 4E-180 series generator operation Failure to follow these instructions may lead to serious injury or even death. This equipment is to be operated by trained and qualified personnel only. Do Not operate this equipment before reading this information.
The Denver High-Cycle Generator is designed to produce 3-Phase, 180 Hertz (High Cycle) electricity and can be wired for either 115 volt or 230 volt (230 volt is the factory setting) and is intended to be used to provide the power to a high-cycle concrete vibrator that has been designed to operate on the supplied power.
Grounding WARNING! Before using the generator make sure that it is properly grounded according to National, State and local codes per site conditions. Consult with a competent, qualified electrician. Failure to properly ground the generator is a potential shock hazard and may result in injury or death.
Getting Started Before using the generator, always do a visual pre-start inspection of the entire generator assembly for any obvious signs of damage, leaks, loose or missing parts. Check all fluid levels and add as necessary. Also, refer to the drive unit manufacturer’s (Honda, Yanmar, Baldor or other) manual for any specific pre-start inspection procedure.
Inspect the running engine and generator section for any loose parts, odd noises, leaks or unusual odors. If any problems are noticed, correct the problem or contact our factory at (800) 395-6703 for further instructions or assistance. If everything appears to be operating normally, proceed to the next step. Using the Power Tool Once the generator has been determined to be properly grounded and in good working condition, you may proceed with using the tool.
Storage If the generator is not going to be used for an extended period of time then it is recommended that the unit be stored indoors. If indoor storage is not possible, keep the unit covered and in a non-moist environment.
FactSheet Grounding Requirements for Portable Generators Portable generators are internal combustion engines used to generate electricity. They are useful when temporary or remote power is needed, and are commonly used during cleanup and recovery efforts following disasters. Major Causes of Injuries and Fatalities frame of a portable generator need not be grounded (connected to earth) and that the Shocks and electrocution to users from...
Page 14
Grounding requirements for generators con- equipment. The ohmic resistance should nected via transfer switches are covered by measure near zero and must not be intermit- Article 250 of the National Electrical Code tent, which indicates a loose connection. (NEC). Bonding Versus Grounding Safe Work Practices for Portable Tools Bonding and grounding are separate require- include:...