SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro-
cess. DO NOT connect the machine to the
power source until instructed to do so.
Amperage Draw
The Model H8170/H8171 motor draws the follow-
ing amps under maximum load:
Motor Draw ............................................ 13 Amps
Circuit Recommendations
We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes. If
you are unsure about the wiring codes in your
area or you plan to connect your machine to a
shared circuit, consult a qualified electrician.
110V Circuit ........................................... 20 Amps
Plug/Receptacle Type
Included Plug Type ........................... NEMA 5-15
Figure 3. Typical type 5-15 plug and receptacle.
-8-
Electrocution or fire could
result if this machine is
not grounded correctly or
if your electrical configu-
ration does not comply
with local and state codes.
Ensure
checking with a qualified
electrician!
This machine must have a ground prong in
the plug to help ensure that it is grounded.
DO NOT remove ground prong from plug
to fit into a two-pronged outlet! If the plug
will not fit the outlet, have the proper outlet
installed by a qualified electrician.
Extension Cords
Follow these instructions when using an exten-
sion cord with your log splitter:
Use at least a 12 gauge cord that does not
exceed 50 feet in length!
The cord must have a ground wire and plug
pin; always keep the cord and plug dry.
A qualified electrician MUST size cords over
50 feet long to prevent motor damage.