Master MH-45-KFA User's Manual And Operating Instructions

Master MH-45-KFA User's Manual And Operating Instructions

Kerosene forced air heaters

Advertisement

Model #s: MH-45-KFA, MH-75T-KFA,
MH-135T-KFA, MH-190T-KFA, MH-215T-KFA
IMPORTANT: Read and understand all of the directions in this manual before assembling,
starting, or servicing the heater. Improper use of this heater can cause serious injury. Keep this
manual for future reference.
GENERAL HAZARD WARNING:
DANGER
Be sure to comply with the instructions and warnings provided with this heater, or death,
serious bodily injury and property loss, damage from the hazards of fire, explosion, burn,
asphyxiation, and carbon monoxide poisoning can result.
Only persons who can follow and understand these instructions should use or service this
heater. If you need heater information such as an instruction manual, labels, etcetera, contact
the manufacturer.
Not for use in residential living areas or in non-adequately ventilated enclosed
DANGER
spaces.
Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA
Phone: 215-891-8460 Fax: 215-891-8461 Web: www.pinnacleint.com Email: info@pinnacleint.com
User's Manual and
Operating Instructions
CONSUMER: Retain this manual for future reference.
Kerosene
Forced Air Heaters
701000110-11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MH-45-KFA and is the answer not in the manual?

Questions and answers

Summary of Contents for Master MH-45-KFA

  • Page 1 If you need heater information such as an instruction manual, labels, etcetera, contact the manufacturer. Not for use in residential living areas or in non-adequately ventilated enclosed DANGER spaces. Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA Phone: 215-891-8460 Fax: 215-891-8461 Web: www.pinnacleint.com Email: info@pinnacleint.com 701000110-11...
  • Page 2: Table Of Contents

    $10,000 other oil compounds in this heater (RISK OF FIRE OR and a term of imprisonment up to 6 months. EXPLOSION). Page 2 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 3: Safety Information

    Front 8 ft. 8 ft. 8 ft. 8 ft. 8 ft. Features Figure 1. Features of Models MH-45/75T-KFA Figure 2. Features of Model MH-135T / 190T / 215T-KFA Page 3 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 4: Specifications

    25” x 26” x 26” Net Weight (Lbs) Specifications subject to change without notice MH-45/75T-KFA 15” 30” 13” MH-135T-KFA 25” 37” 22” MH-190T-KFA MH-215T-KFA 26” 42” 24” Figure 3. Product Dimensions Page 4 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 5: Unpacking

    Hardware Kit Part#: 70-056-0100 70-056-0210 (MH-45 / 75T-KFA) Wheel Nuts Bushings (MH-135T/ 190T / 215T-KFA) Figure 4. Hardware Components Wheel Support Frame Rear Handle Front Handle Axle Figure 5. Frame components, Models MH-135T/190T/215T-KFA Page 5 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 6: Assembly

    Using diesel fuel can cause excess soot production. DO NOT use any fuel that is not approved above. Page 6 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 7: Fuels

    - When temperature is less than 0 ° F, display says “LO”. WARNING - When temperature is above 99 ° F, display says “HI”. Figure 8. Theory of Operation - Between 0 ° and 99 ° F display shows actual temperature. Page 7 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 8: Operation

    - Always keep outlet covered when not in use. Head Flange Storage Drawer (except MH- 45 / 75T-KFA) Cap Flange Electric Outlet (120v 5amp max Seal Cap non fused) Figure 10. Electric Outlet Detail Figure 12. Drain Plug Reinstall Page 8 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 9: Maintenance

    BE SURE FUEL USED IS APPROVED (see OPERATION on page 6). Motor Shaft Fan Blade Flush Figure 14. Fan Replacement Page 9 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 10 Photocell Wire Circuit Board Fuel Filter Screw Installing Photocell: 1) Incorrect Fuel Line 2) Correct Side Cover Figure 17. Photocell Positioning Power Switch Wire Power Switch Figure 19. Fuel Filter Replacement Page 10 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 11 For best measurement of pressure, test with full tank of fuel. Optimum pressure occurs when the nose cone is cherry red and there are no extending flames from the heater. Figure 20. Pump Pressure Adjustment Page 11 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 12: Exploded Parts Drawing

    NEVER LEAVE HEATER Kerosene UNATTENDED WHILE BURN- ING OR WHILE CONNECTED Forced Air Heaters TO A POWER SOURCE Exploded Drawing Part Breakdown Figure 21. Exploded View Models MH-45/75T/135T/190T/215T-KFA Page 12 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 13: Replacement Part Listing

    70-041-0115 70-041-0205 70-041-0205 Wheel (Pneumatic) – – 70-041-0150 70-041-0150 70-041-0150 Wheel Nut – – 70-041-0550 70-041-0550 70-041-0550 Hardware Kit 70-056-0100 70-056-0100 70-056-0210 70-056-0210 70-056-0210 Cord Wrap 70-032-0100 70-032-0100 70-032-0200 70-032-0200 70-032-0200 Page 13 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 14: Wiring Diagrams

    Kerosene UNATTENDED WHILE BURN- ING OR WHILE CONNECTED Forced Air Heaters TO A POWER SOURCE Wiring Diagrams Figure 23 Model MH-75T-KFA Figure 22 Model MH-45-KFA Figure 24 Model MH-135T/ 190T/ 215T-KFA Page 14 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 15: Troubleshooting

    Test power supply 3. Check/replace Fuse 3. Fuse Blown 4. Inspect all electrical connections. Wiring 4. Improper electrical connection between Diagrams (Page 14) Temperature Limit Sensor and Circuit Board Page 15 Pinnacle Products International, Inc. Kerosene User’s Manual...
  • Page 16: Limited Warranty

    Pinnacle Products International, Inc. will Date of Purchase: _________________ repair or replace and return the item, freight pre-paid. If Pinnacle Products International, Inc. finds the item to be in normal operating condition, or not defective, the item will be returned freight collect.This Limited Warranty is in lieu of all other express warranties.

This manual is also suitable for:

Mh-190t-kfaMh-215t-kfaMh-75t-kfaMh-135t-kfa

Table of Contents