Controlpanel - Sears 580.54501 50 Owner's Manual

Table of Contents

Advertisement

6
7
CONTROLPANEL
4
3
1. POWER
key
Pressing this key once
turns the dehumidifier
"ON" and pressing again turns the dehumidifier
"OFF".
2. HUMIDITY
CONTROL
keys
Press to select the desired humidity setting.
• /k : Used to raise the desired humidity setting.
• V : Used to lower the desired humidity setting.
• The desired humidity can be selected within a range of 35% to 70% Relative Humidity in increments
of 5%.
• If you press the V
key once again at 35% Relative Humidity, continuous "On" mode is selected and "On" appears in
the display window. In "On" mode the unit operates continuously,
regardless of humidity conditions.
3. HUMIDITY
SETTING
display
Displays the selected humidity setting.
4. FAN SPEED
key
Press to set the fan speed as "High" or "Low".
• Pressing this key changes the fan speed from High -, Low -* High.
• The selected fan speed is indicated by indicator lights marked "High" and "Low".
5. ENERGY
TIMER
key
Press to select timed operation cycle.
• Pressing this key selects EITHER THE 3 OR 6 HOUR TIMER MODE. The Timer indicator light will shift from 3 hour
On/Off to 6 hour On/Off. The unit wilI run for either 3 or 6 hours, and then shut off completely
for 3 or 6 hours. The
cycle repeats until you change the setting. To turn off the ENERGY TIMER function,
press key until indicator lights
are both "Off".
• If ENERGY TIMER function
is not selected, unit operates until desired humidity setting is reached.
6. BUCKET
FULL
Indicator
This light glows when the bucket is fulI and needs to be emptied. It also glows when the bucket is not properly
positioned. When bucket fulI indicator light glows, the compressor
and fan will turn "OFF".
7. AUTO
RESTART
• The Auto Restart function automatically
restarts your dehumidifier
once power is restored. The fan will immediately
begin to run for approximately
2 minutes, and the unit will operate at the previous humidity setting. After two minutes,
the compressor
may also start based on the humidity conditions
in the room. Once the target humidity setting is
reached, the fan and compressor
wilI shut off.
TO OPERATE THE DEHUMIDIFIER:
1. Plug the power cord into the electrical outlet. Press the POWER key.
2. Set the Humidity control anywhere
between 35% to 70% for normal operation.
• For less humidity, press the V HUMIDITY CONTROL
key.
• For higher humidity, press theA
HUMIDITY CONTROL
key.
3. Press the ENERGY TIMER key if desired, to set the amount of time for which you want the unit to cycle On and Off.
The time can be set for 3 hours or 6 hours.
4. If you want to change the fan speed, press the FAN SPEED key. Each time the FAN SPEED key is pressed the fan
speed changes from High -* Low -_ High.
5. Press the POWER key to stop the unit manually.
-7-

Advertisement

Table of Contents
loading

This manual is also suitable for:

580.54701 70

Table of Contents