All Pro Solutions 30-FAS/SPC-30 Owner's Manual

Forced air propane construction heaters

Advertisement

FORCED AIR PROPANE CONSTRUCTION HEATERS
HEATER SPECIFICATIONS................................................................................................................ 2
WARNINGS .................................................................................................................................. 2
OPERATING PRECAUTIONS ............................................................................................................. 3
SAFETY PRECAUTIONS .................................................................................................................... 3
ODOR FADE WARNING ...................................................................................................................... 4
OPERATING INSTRUCTIONS ............................................................................................................ 5
SERVICING ......................................................................................................................................... 5
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED ........................................................ 6
WIRING DIAGRAMS. ........................................................................................................................... 7
30-FAS / SPC-30 - PARTS ................................................................................................................... 8
55-F / SPC-55 - PARTS ....................................................................................................................... 9
85-FAC / SPC-85 - PARTS ................................................................................................................ 10
125-F / SPC-125 - PARTS .................................................................................................................. 11
WARRANTY ....................................................................................................................................... 12
SERVICE CENTERS ........................................................................................................................ 12
INSTRUCTIONS FOR ORDING PARTS ........................................................................................... 12
WARRANTY REGISTRATION ........................................................................................................... 13
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
OWNERS MANUAL
Models
QUESTIONS?
MISSING / DAMAGED PARTS
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
http://allpro-heaters.com, or call our Customer
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.

TABLE OF CONTENTS

© 2002 Scheu Products Company

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30-FAS/SPC-30 and is the answer not in the manual?

Questions and answers

Summary of Contents for All Pro Solutions 30-FAS/SPC-30

  • Page 1: Table Of Contents

    OWNERS MANUAL FORCED AIR PROPANE CONSTRUCTION HEATERS Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 QUESTIONS? MISSING / DAMAGED PARTS Please do not return this product to the store. If a part is damaged or missing, simply e-mail us at php@allpro-heaters.com, or visit our website at http://allpro-heaters.com, or call our Customer...
  • Page 2: Fas/Spc-30, 55-F/Spc-55, 85-Fac/Spc-85, 125-F/Spc

    Gas Supply Pressure to regulator Maximum: Bottle Pressure Minimum: 5 psig (34.5 kPa) regulator out 28" W.C. (6.97 kPa) (11" W.C. (2.74 kPa) for 30-FAS/SPC-30 Electrical Input: 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 100V Ignition: Direct Spark (manually operated for 30-FAS/SPC-30 heaters)
  • Page 3: Operating Precautions

    Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 OPERATING PRECAUTIONS SAFETY PRECAUTIONS This is a propane, direct-fired, forced air heater. It's intended 1. Check the heater thoroughly for damage. DO NOT operate a use is primarily temporary heating of buildings under damaged heater.
  • Page 4: Odor Fade Warning

    Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 ODOR FADE WARNING WARNING heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the Asphyxiation Hazard heater. • Do not use this heater for heating human living quarters. • Lack of proper ventilation air will lead to improper •...
  • Page 5: Operating Instructions

    Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 OPERATING INSTRUCTIONS SERVICING A hazardous condition may result if a heater is used that has PREPARING FOR OPERATION been modified or is not functioning properly. When the heater is 1. Check the heater for possible shipping damage. If any is working properly: found, immediately notify the factory.
  • Page 6: Size And Capacity Of Propane Cylinders Required

    Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED The charts below show the approximate size of the cylinder required for these heaters. To use the chart: Select the lowest air temperature expected (at the bottom of the chart).
  • Page 7: Wiring Diagrams

    Models 30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125 WIRING DIAGRAMS 30-FAS/SPC-30 CONNECTION DIAGRAM SCHEMATIC DIAGRAM THERMOCOUPLE ELECTRODE HIGH-LIMIT SWITCH MOTOR IGNITION BUTTON THERMOCOUPLE RELAY B** or O** ELECTRODE IGNITOR MOTOR IGNITOR RELAY IGNITION BUTTON HIGH-LIMIT SWITCH 115V R* or Y* 60HZ VALVE R* or Y*...
  • Page 8: 30-Fas / Spc-30 - Parts

    30-FAS / SPC-30 - PARTS Item 30-FAS SPC-30 Description Qty. Item 30-FAS SPC-30 Description Qty. 3455 3486 Front Cover, Housing 3478 3478 Burner Box 3392 3367 Housing, 30-FAS 3517 3517 Blower/Burner Bracket 3393 3369 Rear Cover, Housing 6070 6070 Loop Clamp, 5/16" 6825 6825 Foil AL 2-3 Adhesive Back...
  • Page 9: 55-F / Spc-55 - Parts

    55-F / SPC-55 - PARTS Item 55-F SPC-55 Description Qty. Item 55-F SPC-55 Description Qty. 6152 6152 Hose Assy, LP 6226 6226 Universal Bushing 6257 6257 Regulator 28" WC 6224 6224 Snap Bushing, 1/2 6433 6433 POL Excess Flow 1/4 MPT 6654 6654 Thermocouple 13"...
  • Page 10: 85-Fac / Spc-85 - Parts

    85-FAC / SPC-85 - PARTS Item SPC-85 85-FAC Description Qty. Item SPC-85 85FAC Description Qty. 1670 1730 Cylinder, Outer Assembly 6223 6223 Strain Relief Bushing 6086 6086 Fan, 7 inch 1036 1036 Power Cord 1551 1551 Motor Assembly, 80-FAS 6152 6152 Hose Assembly 1671...
  • Page 11: 125-F / Spc-125 - Parts

    125-F / SPC-125 - PARTS Item SPC-125 125-F Description Qty. Item SPC-125 125-F Description Qty. 1671 1671 Grille Assembly 6227 6227 Snap Bushing, 1 1/4 Nylon 1551 1551 Motor Assembly 7158 7158 Snap Bushing, 3/4 Nylon 7898 7898 Fan, 8" (203.2mm) 6133 6133 Fitting, Coupling...
  • Page 12: Warranty

    SERVICE CENTERS What is covered? This limited warranty covers all imperfections Scheu Products Company has over 1,000 service centers in workmanship and material. throughout North America. Call (888) 619-7060 or e-mail php@scheuco.com to request the service center nearest you.
  • Page 13: Warranty Registration

    Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle. Warranty Registration Your Information First Name Last name Mailing Address State City Postal code E-mail Address Annual house hold income before tax <$9,999 $10,000 to $19,999 >$50,000...
  • Page 14 SCHEU PRODUCTS COMPANY, INC ATTN: MARKETING DEPARTMENT 8855 BAKER AVENUE RANCHO CUCAMONGA, CA 91730 Visit our website for product information, technical support, customer service, and warranty registration at: WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.

This manual is also suitable for:

55-f/spc-55125-f/spc-12585-fac/spc-85

Table of Contents

Save PDF