Performance Specification; Servicing And Repair; Mains Transformer Voltage Selection - Prism Sound MASELEC MASTER MEA-2 Operation Manual

Maselec master series precision stereo equalizer
Table of Contents

Advertisement

Prism Media Products Limited
MASELEC MASTER SERIES
6.3.

Performance specification

Specifications quoted in this section are to AES17-1991 (ANSI S4.51-1991) [Ref. 1], with
input level set to +22dBu except where stated. For 'EQ in' measurements, the CH1/CH2
'In' buttons are illuminated and other settings are : LF1 - Shelf, LF2 - Bell, slope 9, HF1
Bell, slope 9, HF2 Shelf. Gain for each section is set to 0dB.
Maximum input amplitude :
Output noise :
Frequency response :
Crosstalk :
Harmonic distortion and noise, EQ in :
Dynamic range :
(Measured at -32dBu)
6.4.

Servicing and repair

There are no user serviceable parts inside this unit. Repairs should only be undertaken
by qualified electronics technicians or engineers.
6.5.

Mains transformer voltage selection

The mains transformer has a tapped primary to allow operation at nominal voltages of
120V or 240V. A rear-panel slide switch selects the mains voltage range. Ensure that
the correct voltage range is selected before using the MEA-2.
6.5.1.
Mains voltage range :
6.5.2.
Power consumption :
Issue 1.2
17 January 2000
90-130V (nominally 120V) or 180-260V
(nominally 240V) operation. The selected
supply voltage range is indicated on the rear
panel slide switch.
15W max.
© Prism Media Products Limited
MEA-2 Precision Stereo Equalizer
+28dBu
EQ out < -97dBu
EQ in < -89dBu
+ 0.1, -0.4dB, <1Hz to > 50 kHz
less than -100 dB, 20 Hz to 20 kHz
Un-driven input terminated 150R
<-105dB (<0.0006%), 997 Hz
EQ out
> 125dB
EQ in
> 117dB
Operation Manual
Page 13 of 20

Advertisement

Table of Contents
loading

Related Products for Prism Sound MASELEC MASTER MEA-2

Table of Contents