DIGITAL MULTIMETER
3.2.4 AC Current
Range
Resolution
400 A
0.1 A
4000 A
1 A
40mA
10 A
400mA
100 A
4A
1mA
10A
10mA
- Overload protection:
A
m A ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting),.
- Max. input current:
mA jack
A ranges
: 4mA,
mA jack
m A ranges
: 400mA,
10A jack: 10A
- voltage drop
400 A ranges: 40mV,
4000 A ranges: 400mV,
40mA ranges: 40mV,
400mA ranges: 400mV,
4A range: 40mV
10A range: 100mV
- Frequency range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave
- 16 -
SPECIFICATION NTS
Accuracy
1 .5% of reading + 5 digits
3 .0% of reading + 10 digits
DIGITAL MULTIMETER
3.2.5 Resistance
Range
Resolution
400
0.1
4k
1
40k
10
400k(
100
4M(
1k
40M(
10k
- Open circuit voltage: ~0.25V
- Overload protection: 250V DC or rms AC
3.2.6 Capacitance
Range
Resolution
40nF
10pF
400nF
0.1nF
4 F
1nF
40 F
10nF
100 F
100nF
- Overload protection: 250V DC or rms AC
SPECIFICATION NTS
Accuracy
(1.2% of reading + 2 digits)
(2.0% of reading + 5 digits)
Accuracy
3 .0% of reading + 3 digits
- 17 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

98674

Table of Contents