Download Print this page

ExelTech XP600 Installation And Operation Manual

Sine-wave inverter
Hide thumbs Also See for XP600:

Advertisement

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL
7317 Jack Newell Blvd. North
Fort Worth, Texas 76118-7100
817-595-4969 voice, 817-595-1290 fax
800-886-4683 toll free
website www.exeltech.com
Manufacturer of UL Listed Products

Advertisement

loading
Need help?

Need help?

Do you have a question about the XP600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ExelTech XP600

  • Page 1 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL 7317 Jack Newell Blvd. North Fort Worth, Texas 76118-7100 817-595-4969 voice, 817-595-1290 fax 800-886-4683 toll free website www.exeltech.com Manufacturer of UL Listed Products...
  • Page 2 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL Copyright © 2010 Exeltech Inc. All rights reserved. This Document may not be copied, photocopied, reproduced, translated or converted to any electronic or machine-readable form in whole or in part without prior written approval of Exeltech Inc.
  • Page 3: Table Of Contents

    XP600/1100/2000 INSTALLATION AND OPERATION MANUAL Table of Contents page 3 Introduction 1.0 Standard Features 2.0 page 5 Installation 3.0 page 8 Operation 4.0 page 11 Appendix A page 12 Appendix B page 14 Appendix C page 16 Page 2...
  • Page 4: Introduction 1.0

    TL 9000 standards and beyond, adding people and procedures continually to further improve quality and customer service. We welcome you as a customer to the Exeltech family. Congratulations! XP series inverters provide the cleanest, best regulated sine wave output over the widest DC input of any inverter on the market today.
  • Page 5 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL specify these products is in watts (W), which is power the inverter can actually deliver. If Exeltech inverters were specified in VA, our 1100 watt inverter could be rated at 1375 VA @ 0.8 power factor, 1570 VA@ .7 pf, or an incredible 2200 VA @ 0.5 pf.;...
  • Page 6 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL tandard Features DC INPUTS: Positive (+) and Negative (-) input terminals are 3/8" studs with brass hardware. They are accessed under the rear cover. Use “Appendix A” to choose the appropriate gauge wire for your specific model.
  • Page 7 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL OVER VOLTAGE PROTECTION: When input voltage to the inverter exceeds set limits, the inverter will immediately and without warning shut off. When input voltage returns to normal range, the inverter will immediately restart. Since high over voltages tend to have very fast edges, the inverter must shut down quickly to protect itself.
  • Page 8 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL OVERPOWER, SHORT CIRCUIT PROTECTION: XP600/ 1100 inverters have three levels of overpower protection. The first limits peak instantaneous current. The second system limits absolute power coming from the module. Both of these circuits act to reduce output voltage as required, to limit current to a safe level The overpower protection circuit will recover instantly when the overpower condition clears.
  • Page 9: Installation 3.0

    XP600/1100/2000 INSTALLATION AND OPERATION MANUAL nstallation CAUTION: It is essential to read and understand all Warnings, Cautions, and Notes before any connections are made to the unit or system. If further assistance is needed call (817) 595- 4969 and ask for Customer Service.
  • Page 10 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL The Negative or Positive terminal of the battery (DC Source) must be bonded to earth ground. It's recommended that it be to the same earth ground used for AC ground. La borne négative ou positive de la batterie terminal doit être lié...
  • Page 11 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL Inverter requires adequate ventilation for cooling. With proper cooling, the inverter will operate efficiently and meet its published ratings. All models can be mounted in several positions. Best position, with fan down. Second best, horizontal. Third, vertical with fan up.
  • Page 12: Operation 4.0

    XP600/1100/2000 INSTALLATION AND OPERATION MANUAL peration TURN ON INVERTER: XP-600, XP-1100 and XP-2000: Turn inverter on using Toggle Switch on Front Panel, or the "REMOTE" switch if installed. LED next to the switch will illuminate, indicating the inverter is operational.
  • Page 13 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL APPENDIX Input Power Requirements: RATED PEAK NORMAL MINIMUM VDC MAXIMUM CURRENT CURRENT MODEL CUT-OFF / ALARM AMPS AMPS 13.8 VDC 10.4 / 10.6 VDC 51.2 A XP-600 / 12VDC 16.5 VDC 99.9 A XP-600 / 24VDC 27.6 VDC...
  • Page 14 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL OUTPUT POWER CONTINUOUS SURGE NO LOAD OUTPUT WEIGHT OUTPUT POWER POWER POWER VOLTAGE CURRENT LBS. 600W 1100W 100 +/-6% 600W 1100W 117 +/-6% 600W 1100W 230 +/-6% 1100W 2200W 20W* 100 +/-6% 11.0 1100W 2200W...
  • Page 15: Appendix B

    XP600/1100/2000 INSTALLATION AND OPERATION MANUAL APPENDIX 12.100 XP-600 9.342 8.897 0.125 DIA. 4 PLCS .281 3/4” KNOCK-OUT 1.280 .780 FRONT SIDE 3.565 3.565 15.050 XP-1100 12.345 11.842 0.125 DIA. 4 PLCS 1.280 3/4” KNOCK-OUT .281 .780 FRONT SIDE 3.565 3.565...
  • Page 16 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL XP-2000 17.678 15.420 13.420 R.133 3/4” KNOCK-OUT 2.410 .266 3.386 FRONT SIDE Page 15...
  • Page 17: Appendix C

    XP600/1100/2000 INSTALLATION AND OPERATION MANUAL APPENDIX INSTALLATION CAUTION: Terminate all connections to the inverter BEFORE connecting DC leads to the battery. ATTENTION: Mettre fin à toutes les connexions à l'onduleur avant de brancher mène à la batterie. XP-600 and XP-1100 Rear View with access cover removed...
  • Page 18 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL XP-2000 Rear View with access cover removed (AC/DC Connections): BAT + BAT - Bonding strip Page 17...
  • Page 19 XP600/1100/2000 INSTALLATION AND OPERATION MANUAL Made in the USA 7317 Jack Newell Blvd. North Fort Worth, Texas 76118-7100 817-595-4969 voice, 817-595-1290 fax 800-886-4683 toll free website www.exeltech.com Document subject to change without notice. 931-X61M*-*0H...

This manual is also suitable for:

Xp1100Xp2000