Torque Table
Find the proper torque specifications for your surge suppressor unit in the table below. These are the torques to
which the clamp band, ring flange, or bolts in bolted units need to be tightened.
KEY: plastic = polypropylene or acetal
metal = stainless steel
rubber = fluoroelastomer or Buna–N
Bladder
Model
Material
Husky 2000
rubber
Husky 2000
rubber
Husky 2000
PTFE
Husky 2000
rubber
Husky 2000
rubber
Husky 2000
PTFE
Husky 2000
rubber
Husky 2000
PTFE
Husky 750
rubber
Husky 750
rubber
Husky 750
PTFE
Husky 750
PTFE
Husky 750
rubber
Husky 750
PTFE
Service
Housing
Material
Type of Clamp
plastic
clamp band
plastic
ring flange
plastic
ring flange
metal and plastic
clamp band
metal and plastic
ring flange
metal and plastic
ring flange
metal
bolted unit
metal
bolted unit
plastic
clamp band
plastic
ring flange
plastic
clamp band
plastic
ring flange
metal
bolted unit
metal
bolted unit
Torque
45 to 55 in-lb (5.1 to 6.2 N-m)
65 to 70 in-lb (7.3 to 7.9 N-m)
90 to 105 in-lb (10.2 to 11.9 N-m)
30 to 40 in-lb (3.4 to 4.5 N-m)
80 to 85 in-lb (9.0 to 9.6 N-m)
90 to 95 in-lb (10.2 to10.7 N-m)
120 to 130 in-lb (13.6 to 14.7 N-m)
145 to 150 in-lb (16.4 to 16.9 N-m)
40 to 45 in-lb (4.5 to 5.1 N-m)
50 to 55 in-lb (5.6 to 6.2 N-m)
80 to 85 in-lb (6.8 to 9.6 N-m)
85 to 90 in-lb (9.6 to 10.2 N-m)
80 to 85 in-lb (9.0 to 9.6 N-m)
110 to 115 in-lb (12.4 to 13.0 N-m)