  • Page 1 Keypads WK-3/WK-4 Owner’s Manual McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 FAX: 607-724-0549...
  • Page 2: Safety Instructions

    The lightning flash with arrowhead, The exclamation point within an within an equilateral triangle, is in- equilateral triangle is intended to tended to alert the user to the pres- alert the user to the presence of ence of uninsulated “dangerous volt- important operating and mainte- age”...
  • Page 3: Thank You

    When a cart is used, use caution Thank You when moving the cart/apparatus Thank you for your decision to own this McIntosh WK-3 or WK-4 Keypad. The combination to avoid injury from McIntosh dedication to “Quality” is assur- tip-over. ance that it will provide you with many 13.
  • Page 4: Table Of Contents

    Follow the hookup connections below: WK-4 Front Panel Display Keypad External and Push-Buttons ......... 12 Shielded DC Power How to Operate the WK-3 and WK-4 . 13 Cable Supply Specifications ........15 12 Volts Packing Instruction ......15 @50mA “F” Connector...
  • Page 5: Connector Information

    7. The DVD Source Selection Push-button on RJ-45 Socket the WK-3 and WK-4 Keypads is labeled as 1. Signal Data V-AUX on earlier McIntosh A/V Control 2. Signal Data Gnd. and Cable Shield Centers, Multizone Controllers and 3.
  • Page 6: Introduction

    Introduction and Performance Features Introduction The McIntosh WK-3 and WK-4 keypads Integrates with the Remote Control allow convenient push-button remote con- Translator trol of McIntosh A/V Control Centers, The Keypads work together with a McIn- Multizone Controller and Preamplifiers. tosh Remote Control Translator to provide...
  • Page 7: Installation And Dimensions

    " 11/16 wall opening, piece of furniture or cabinet 43mm of your choice. The WK-3 will fit in a standard NEMA, 1-gang, sheet-steel or non-metallic outlet box with a depth of 2- WK-3 1/2 inches. The WK-3 can be mounted di-...
  • Page 8: Installation And Dimensions

    WK-4 Dimension and Installation WK-4 Dimension and Installation WK-4 Bottom View The WK-4 can be custom installed in a " 5/16 wall opening, piece of furniture or cabinet 135mm of your choice. The WK-4 will fit in a standard NEMA, 3-gang, sheet-steel or non-metallic outlet box with a depth of 2- 1/2 inches.
  • Page 9: How To Connect With The 5-Pin Terminal Connector

    How to Connect with the 5-Pin Terminal Connector 1. Connect one end of a shielded 4 con- 2. Connect the WK-3 Keypad in a similar ductor cable from the WK-4 Keypad manner as above except connect the 5- Connector to the 5-Pin Terminal Con-...
  • Page 10: How To Connect With The Rj45 Connector

    Connector 1. Connect one end of a shielded 4 con- 2. Connect the WK-4 Keypad in a similar ductor cable from the WK-3 Keypad manner as above except connect the Connector to the RJ45 Connector RJ45 Plug to the Zone B RJ45 Socket Plug, refer to adjacent chart along with of the McIntosh A/V Controller.
  • Page 11: Front Panel Push-Buttons

    WK-3 Front Panel Push-Buttons IR sensor Select any of five signal sources Perform operating function on a Tuner, or Disc Player Turns entire system off Turns the zone Adjusts volume you are in on up or down in the or off...
  • Page 12: Front Panel Display And Push-Buttons

    Turns power On/Off Perform function Select tuner pre- to a component con- on a component sets or any num- nected via a data port connected with a bered operation or McIntosh Remote Remote Control Control Translator Translator...
  • Page 13: How To Operate The Wk-3 And

    Press again to unmute. Note: Refer to page 11 for the WK-3 and page 12 for the Wk-4. 0-9 Numbered Push-buttons Press a number push-button to select tracks...
  • Page 14 How to Operate the WK-4 con’t Note: This condition is usually caused by Sleep function, press Sleep again. The either interruptions in AC power zone will now turn off. and/or major changes in voltage. How To Set a Timed On-Off Event How To Set the Keypad Clock Time Press and Hold the Set On push-button for Press and Hold the Clock push-button for...
  • Page 15: Specifications

    Specifications and Packing Instructions WK-3 Specifications WK-3 and WK-4 Packing Instructions Power Requirements In the event it is necessary to repack the 12 Volts, D.C. @43mA equipment for shipment, use the original shipping carton and interior parts only if Dimensions they are all in good serviceable condition.
  • Page 16 McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, NY 13903 The continuous improvement of its products is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice. Printed in the U.S.A. McIntosh Part No. 04059101...