Download Print this page

GERATHERM DUOTEMP GEF-100 Instructions For Use Manual

Digital ear and forehead thermometer
Hide thumbs Also See for DUOTEMP GEF-100:

Advertisement

DIGITAL EAR AND
FOREHEAD THERMOMETER
GB
INSTRUCTIONS FOR USE
Geratherm Duotemp GEF-100

Advertisement

loading

Summary of Contents for GERATHERM DUOTEMP GEF-100

  • Page 1 DIGITAL EAR AND FOREHEAD THERMOMETER INSTRUCTIONS FOR USE Geratherm Duotemp GEF-100...
  • Page 2: Specifications

    CONTENTS SPECIFICATIONS The parts of the unit 1 - GB Point of Infra-red measurement at Specifi cations 2 - GB measurement the eardrum or forehead What is body temperature? 4 - GB Measuring range Temperature measurement - Ear 5 - GB Ear Mode: 0 - 100 °C (32 - 212 °F) Temperature measurement –...
  • Page 3: What Is Body Temperature

    WHAT IS BODY TEMPERATURE? Body temperature refers to the internal tempe- • Store out of children’s reach! Measurement rature of the body (core temperature). ‘Normal’ of children’s temperatures must be conducted body temperature fl uctuates over the course of 24 hours. It tends to be lowest in the early under adult supervision! morning and highest in the late afternoon.
  • Page 4 TEMPERATURE MEASUREMENT - EAR Press the ON button and In order to ensure accurate measurement, the wait until you hear a beep. patient should fi rst rest for 20 minutes in the If no beep is heard, press same room as the thermometer. Immediately and release the ON button after exercise or a bath, the temperature may again.
  • Page 5 TEMPERATURE MEASUREMENT - Read the temperature FOREHEAD value displayed on the LCD panel. In order to ensure accurate measurement, the patient should fi rst rest for 20 minutes in the • The precise sensing system records same room as the thermometer. Immediately the heat emitted naturally through the the heat emitted naturally through the after exercise or a bath, the temperature may...
  • Page 6 MEMORY In order to switch over to Celcius (°C), press the MEM button and then press Press the MEM button. and release the ON button while the memory cell number is displayed on the The fi rst memory cell LCD panel. number (“0”) will then show the stored tempera- ture (the last reading).
  • Page 7 FAULT INDICATION FAULT OR FAULT DE- CORRECTIVE The battery Replace the has run out. battery. FAULT SCRIPTION MEASURE SYMBOL symbol is No display The battery Replace the displayed on the LCD has run out. battery. Ple- panel Incorrect bat- ase note: The thermo- Wait until the tery polarity.
  • Page 8 Invoice No. / Receipt No.: ....Manufacturer: Geratherm Medical AG Name and address of dealer: ....