Download Print this page

Crown FM30 User Manual page 99

Broadcast transmitters
Hide thumbs Also See for FM30:

Advertisement

The following lists describe the spare parts kit available for
your transmitter.
For the FM100 and FM250, use part number
GFMSPARES. The following parts are included:
Item
Fuse, 4A Slo-blo 5mmX20mm
Fuse, 6.3A Slo-blo 5mmX20mm
Fuse, 12.5A Slo-blo 5mmX20mm
15A 100V N-CH MOSFET
130V RMS 200V PEAK 6500A ZENER
35A 400V Bridge Rectifier
Diode, BYV72E–150 20A 150V
MOS Gate Driver, 500V IR #IR2125
MOSFET, RF Philips #BLF278
Switching Regulator, 0.75A LM3578AN 2
NTC, In-rush Current Limiter
EMI Filter, 6A 250V with Fuse
14 Stage Bin Cntr/OSC 74HC4060
These parts are included in the FM30 kit (part number
GFM30SPARES):
Item
Fuse, 1.5A Slo-blo 5mmX20mm
Fuse, 3A Slo-blo 5mmX20mm
15A 100V N-CH MOSFET
130V RMS 200V PEAK 6500A ZENER
35A 400V Bridge Rectifier
Diode, BYV72E–150 20A 150V
MOS Gate Driver, 500V IR #IR2125
Switching Regulator, 0.75A LM3578AN 2
NTC, In-rush Current Limiter
MRF137 FET PWR XISTOR
EMI Filter, 6A 250V with Fuse
14 Stage Bin Cntr/OSC 74HC4060
7–4
Quantity
6
5
5
2
2
1
2
2
1
2
1
1
Quantity
6
5
2
2
1
2
2
2
1
1
1