FLOJET 2100-12 Specifications

FLOJET 2100-12 Specifications

2100 series duplex diaphragm design automatic water system pump & shower drain • general purpose pump

Advertisement

Quick Links

FEATURES
• Self-Priming
• Dry Running
• Automatic Operation
• Models Meet U.S.C.G. Electrical Standards
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing. CE Models
are fully suppressed.
Pump: Two chamber diaphragm design; Self-priming
up to 6 ft. suction lift; Pump able to run dry
without damage.
Port:
Pump housing inlet and outlet are 3/8" NPT
female threads.
MODEL*
VOLTS
2100-12
12V dc
2100-694**
12V dc
2100-740
24V dc
2100-750
12V dc
*CE fully suppressed models are identified by a prefix "R" and a CE mark on the label. (i.e. R2100-740)
Self Declaration Of Conformance (SDOC) is available upon request.
**Shower Drain Model only, does not include port connectors, see Accessories to order connectors.
OPERATION FOR
WATER SYSTEM PUMPS
The FLOJET 2100 series pumps are automatic demand
pumps. They will automatically turn on when a fixture is
opened and turn off when all fixtures are closed.
When starting from a completely drained system allow
time for the demand pump to fill the hot water tank. After
refilling the tank the pump is reprimed by opening a
fixture. Allow air to vent and close fixture when water
flow is steady. Faucet strainers and aerators should be
cleaned regularly.
AMP DRAW
@ 10 psi (0.7 bar)
2.5
2.5
1.5
2.5
Duplex Diaphragm Design
Automatic Water System Pump &
Shower Drain • General Purpose Pump
Pump Series
Dimensions - Inches (mm)
Height
2100-XXX
3.75 (95) 3.25 (83)
FUSE
FLOW
AMPS
GPM (l/min)
7
2.3 (8.7)
7
2.3 (8.7)
5
2.3 (8.7)
7
2.3 (8.7)
OPERATION FOR
THE SHOWER DRAIN PUMP
Model 2100-694 is a utility/shower drain pump. The
pump will not turn off automatically. Your shower drain
pump is designed to self-prime up to 6 feet suction lift
(vertical distance from shower pan to pump inlet). It is
recommended you utilize a "lighted" on-off switch so
that pump is turned off when not in use. The pump is
able to run dry (no liquid) for extended periods with no
damage to the pump, however this could cause
needless battery drain.
Models2100 Series
Width
Length
8.2 (208) 3.3 (1.5)
PRESSURE SWITCH PSI (BAR)
ON
15 (1)
30 (2)
No Pressure Switch
15 (1)
30 (2)
15 (1)
30 (2)
Weight
lb. (kg)
OFF

Advertisement

loading

Summary of Contents for FLOJET 2100-12

  • Page 1 OPERATION FOR WATER SYSTEM PUMPS THE SHOWER DRAIN PUMP The FLOJET 2100 series pumps are automatic demand Model 2100-694 is a utility/shower drain pump. The pumps. They will automatically turn on when a fixture is pump will not turn off automatically. Your shower drain opened and turn off when all fixtures are closed.
  • Page 2 Insert rubber mounting grommets onto base plate. STEP 7 STEP 4 Install a Flojet strainer in an accessible location (for Mount pump vertically, with pump head down or inspection and cleaning) between the tank and pump horizontally in an accessible location. Do not compress inlet.
  • Page 3 • Defective motor • Blown fuse Quite often when a pump is worn or defective the one failed component has overburdened others. To avoid frequent aggravating repairs, Flojet offers service kit assemblies making repairs as quick and easy as possible. DISASSEMBLE REASSEMBLE...
  • Page 4 FLOJET. During this one year warranty period, side of the shipping- package. Place a note inside the package FLOJET will at its option, at no charge to the customer, repair or with an explanation regarding the reason for return as well as the replace this product if found defective, with a new or reconditioned authorization number.