9. Adjusting the Reference Positions

If the reference positions are not properly adjusted for all hands, the watch
improperly operates.
When the reference positions are found improper, perform the following
procedure to adjust the reference position of each hand. (This procedure must
also be completed after battery replacement.)
Year
Day of the month
Day of the week
Month
16
(1) Pull the crown out to the
second click position.
(2) Simultaneously press
three buttons that are
designated (A), (B), and
(C). This causes the
Crown
year, month, date, and
day-of-the-week hands
to sequentially start
moving.
Reference position=December 31,
2000 (sun.)
<Reference positioning failure warning function>
If you push the crown into its normal position without performing the button
manipulation procedure after completion of Steps (1) and (2), the year hand
rapidly moves in reverse direction to alert you that the reference positions are
improperly adjusted.
When you encounter the above situation, adjust the reference positions of all
hands by performing the specified procedure again.
(3) Press button (A) to set the year hand
to the year 2000.
(4) Press button (B) to set the month and
date hands to December 31. (The
month hand moves in conjunction
with the day hand.)
(5) Press button (C) to place the day-of-
the-week hand in the Sunday (SUN)
position.
* Continued pressing of button (A) and
button (B) will forward the hands
rapidly.