Azden PCS-6000H Instruction Manual page 10

2m fm transceiver
Table of Contents

Advertisement

After a round of procedures for storing the receiving and transmitting frequencies and
tone code, the Memory Address Indicator flickers showing the next channel. By repeating
the same procedures as above, you can store r eceive frequencies, receive tones, as well as
transmit frequencies and transmit tones in the memory bank AD through A9 and memory
bank BO through B 9 for a total of 20 channels.
After the tone code is entered in the B9 memory channel, the unit is in the Up/Down
mode for setting tone, shift width, delay scan and frequency stop other than in the memory
channels.
1. The receiving tone code will be indicated by entering tone code number.
Press the M MODE key and the TONE indicator will flicker.
Select any desired tone code by the UP/DOWN key and push the M MODE key
to complete the entry.
Note: This procedure is not required unless the unit is provided with the tone squelch unit.
2. By the transmit tone code number, the transmit tone code will be indicated. Pushing the M
MODE key to let the indicator flicker. Then, select tone code desired by the use of the
UP/DOWN key and push the M MODE key again to complete the entry.
3. Scanning Mode: The "3 00" appears on the display, indicating that the unit in the Delay
Scan mode.
Pushing the N MODE key and the indicator will flicker. Select either "3" or '6" by the
UP/DOWN key and press again the M MODE key to decide 3 seconds or 6 seconds HOLD
mode.
4. Frequency Step: The display is indicated as "4 . 5Mhz" to denote that the up/down
frequency step is set to 5kHz. Pressing the N MODE key will indicator flicker. Select the
desired frequency step from among "5" (5kHz), "10(10kHz), "l5"(15kHz) and
"20"(2OkHz) by the UP/DOWN key and press the M MODE key to decide the frequency
step.
5. Shift Width: The display indicates "5 .600MHz" that means shift width is 600kHz. Press
the M MODE key to let the indicator flicker and select any desired shift width by the
UP/DOWN key and press the M MODE key again to complete the shift width setup.
The unit then returns to the initial program mode Status and 'AD' will flicker.
The above will complete all the program setting procedures. To release the program mode,
be sure to turn the POWER off.
Note: When the unit is in the program mode, the M MODE key accepts memory and
program entry even if 'F' is indicated.
—9—

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents