Download Print this page
Panasonic WhisperGreen FV-13VKS3 Specifications
Panasonic WhisperGreen FV-13VKS3 Specifications

Panasonic WhisperGreen FV-13VKS3 Specifications

Ventilation fan
Hide thumbs Also See for WhisperGreen FV-13VKS3:

Advertisement

Specification Data
Panasonic Ventilation Fan
Description
Ventilating fan shall be Low Noise ceiling mount type rated for continuous
run. Fan shall be ENERGY STAR rated and certified by the Home Ventilating
Institute (HVI). Evaluated by Underwriters Laboratories and conform to both
UL and cUL safety standards.
Motor/Blower:
Totally enclosed DC brushless motor technology, currently more energy
efficient than the minimum ENERGY STAR requirements, rated for
continuous run.
Power Rating shall be 120 volts and 60 Hz.
Fan shall be UL listed for tub/shower enclosure when used with
a GFCI branch circuit wiring.
Motor equipped with thermal cut-off fuse control.
Removable with permanently lubricated plug–in motor.
Housing:
Rust proof paint, galvanized steel body.
Detachable 6" diameter duct adapter.
Built-in backdraft damper.
Expandable extension bracket up to 24".
Double hanger bar system allowing for ideal positioning.
Grille:
Attractive design using PP material.
Attaches directly to housing with torsion springs.
Warranty:
The factory warranty shall be a minimum of 6 years limited warranty on
the motor and 3 year limited warranty on parts.
Typical Specifications:
Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type, with
variable speed of 0-130 CFM and no more than 0.3 sone as certified by the Home
Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge. Power
consumption shall be no greater than 11.9 watts and ENERGY STAR rated with
efficiency rating of no less than 11.2 CFM/watt. The motor shall be enclosed
with brushless DC motor engineered to run continuously. Power rating shall be
120v/60Hz. Duct diameter shall be no less than 6". Fan shall be UL and cUL
liste
d for tub/shower enclosure when used with GFCI branch circuit wiring.
Fan shall be California Title 24 compliant.
DC Motor Technology:
Allows the fan to run continuously at a pre-set lower level (0, 50 – 110 CFM).
The fan then elevates to a maximum level of operation (130 CFM) when
the switch is turned on.
When fan faces static pressure, its speed is automatically increased to
ensure that the desired CFM is not compromised, which allows the fan to
perform as rated.
WhisperGreen
Static Pressure in inches w.g.
Air Volume (CFM)
Noise (sones)
Power Consumption (watts)
Energy Efficiency (CFM/Watt)
Speed (RPM)
Current (amps)
As of 1/11
For Complete Installation Instructions Visit www.panasonic.com/building
Model
Quantity
Panasonic Home & Environment
0.1
0.25
130
135
<0.3
0.7
<0.3
11.9
21.5
11.2
6.4
12.5
662
917
0.01
0.12
0.03
Comments
|
|
One Panasonic Way
Secaucus, NJ 07094
FV-13VKS3
0.90
0.75
0.60
0.45
0.30
0.15
0.00
0
FV-13VKS3
0.1
0.25
0.1
0.25
110
111
90
93
0.6
<0.3
0.6
9.0
15.6
6.2
12.5
7.3
15.2
7.8
643
912
580
900
0.09
0.02
0.07
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
|
866-292-7292
®
(0-130 CFM)
FV-13VKS3
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
110 CFM
90 CFM
70 CFM
50 CFM
50
100
150
A i rfl ow (C F M )
0.1
0.25
0.1
0.25
70
71
50
<0.3
0.4
<0.3
<0.3
4.1
9.8
2.4
18.7
7.9
23.3
10.0
506
874
430
0.04
0.01
0.06
0.03
|
www.panasonic.com/building
53
5.9
781

Advertisement