  • Page 1 BRILLANTE User Manual Teleste Corporation BRILLANTE High Speed Data Processor...
  • Page 2: Table Of Contents

    ETHERNET connections .........................7 Static Routes.............................8 Rebooting ..............................9 Command Prompt ..........................10 BRILLANTE commands ......................10 Password protected commands: ....................11 Configuring the BRILLANTE Editing the main configuration file......................12 BRILLANTE configuration file sections ....................12 <HEADER>..........................12 <BRILLANTE>........................12 <ECMG_LIST> ........................13 <SERVICES> ..........................13 <SERVICEGROUPS>......................14 <ECMSTREAMS> ........................14 <EMMG_LIST> ........................15 <EMMSTREAMS>...
  • Page 3 Available commands:.......................22 EMM console menu ..........................22 Available commands:.......................22 SIGEN console menu ..........................23 Available commands:.......................23 Spare ECMG in brief Overview ..............................24 Configuration ............................24 BRILLANTE 1+1 backup in brief Fail-over switching..........................26 Configuration ............................26 Configuration File ..........................27 Triggers ..............................29 ATM............................29 ECMG............................29 Application crash ........................29 Ethernet............................29...
  • Page 4: Introduction

    BRILLANTE is used as an interface unit between third party Conditional Access System and Teleste ATMux system. The primary task of BRILLANTE is to take care of the communication between the ECM generators, EMM/PD (private data) injectors and Teleste ATMux system.
  • Page 5 Automatic 1+1 full backup and automatic unit switching • DVB simulcrypt v2.0 compatibility • Supports up to three CA systems per service (simulcrypted) • Open CAS support • Provides a simple way of handling Pay Per View services internally Introduction • 4 BRILLANTE User Manual, 59300023, rev005...
  • Page 6: Installation

    230 VAC wall outlet. For more detailed instructions refer to the IBM user manual. • Power up the BRILLANTE and see that the indicators on the front panel of the unit are lit. • Proceed by establishing the Ethernet connection through the TCP/IP network by filling in the required parameters as described in the next chapter.
  • Page 7: Establishing A Data Connection

    After powering up the initial display will prompt for a “BRILLANTE login”; enter: system and password system admin and password admin (Depending on which user level you wish to log in.) Establishing a Data Connection • 6 BRILLANTE User Manual, 59300023, rev005...
  • Page 8: Ethernet Connections

    To configure the Ethernet connections requires the user to log in as an “admin” (previous page). All the settings of Ethernet connections can be edited by using BRILLANTE configurator script (cfgrtr.sh) or by editing system files directly as shown below.
  • Page 9: Static Routes

    (closes the old eth0 connection on port 1) ifup eth0 (the new settings takes effect) If both of Ethernet ports (1 & 2) on the BRILLANTE’s back panel are in use proceed by entering: pico -w ifcfg-eth1 Continue as in the case of eth0.
  • Page 10: Rebooting

    = subnet mask gw = gateway or router *************************************************** Rebooting Reboot by entering: reboot Confirm by typing your own user password system or admin (same as you entered when logging in) Establishing a Data Connection • 9 BRILLANTE User Manual, 59300023, rev005...
  • Page 11: Command Prompt

    SI Generator Menu, start/stop/restart sigen process. redundance.sh BRILLANTE 1+1 redundancy script to control main and backup units, for more details refer to the ‘BRILLANTE 1+1 backup in brief ’ -section in this document. cfgrtr.sh Brillante configurator menu. Edit and handle some basic settings. ppvrun...
  • Page 12: Password Protected Commands

    Password protected commands: reboot Reboots the BRILLANTE. poweroff Halts the BRILLANTE so that power can be safely turned off. NOTE! Poweroff command has to be used always when shutting down BRILLANTE. Establishing a Data Connection • 11 BRILLANTE User Manual, 59300023, rev005...
  • Page 13: Configuring The Brillante

    Version of configuration file format. Do not change! <BRILLANTE> scs_pool Address and port of BRILLANTE scs application process. Normally processes are run in local host and there is no need to change the default. emm_relay Address and port of BRILLANTE emm...
  • Page 14: Ecmg_List

    Service Name User defined name of the service for which the ECM stream is used. No duplicate names are allowed. TSID Transport Stream ID, no need to configure, reserved for future. Configuring the BRILLANTE • 13 BRILLANTE User Manual, 59300023, rev005...
  • Page 15: Servicegroups

    This setting overrides the default CP of corresponding ECM generator configured in <ECMG_LIST>. Initial Scrambling Initial state to indicate if the service shall be scrambled or unscrambled by default. Configuring the BRILLANTE • 14 BRILLANTE User Manual, 59300023, rev005...
  • Page 16: Emmg_List

    <EMMFORWARD> Name User defined name another BRILLANTE located in sub-headend. No duplicate names are allowed. IPaddr:Port IP address and port of the sub-headend BRILLANTE where the data shall be forwarded. Configuring the BRILLANTE • 15 BRILLANTE User Manual, 59300023, rev005...
  • Page 17: Example Configuration, Bril.conf

    0x30000030 </ECMSTREAMS> <EMMG_LIST> EMMG name Client ID x1_EMMG 0x0A001234 x2_EMMG 0x070900AB </EMMG_LIST> <EMMSTREAMS> EMMG name Data ID Bitrate (kbits/s) x1_EMMG 0x0001 x2_EMMG 0x0003 </EMMSTREAMS> <EMMFORWARD> Name IPaddr:Port Bril@Subheadend 10.136.0.16:5000 </EMMFORWARD> Configuring the BRILLANTE • 16 BRILLANTE User Manual, 59300023, rev005...
  • Page 18: Editing The Sigen Configuration File

    This value is allocated by the user. <TDT> Server Name Name of the server where the data will be sent. This name has to be defined in <SERVER_LIST> section otherwise an error will be reported. Configuring the BRILLANTE • 17 BRILLANTE User Manual, 59300023, rev005...
  • Page 19: Tot

    CA_PID The PID value of the Transport Stream packets which contains information for the CA systems as specified with associated CA_System_ID. Valid range: 0…8191. Refer value <EMMSTREAMS> section in bril.conf. Configuring the BRILLANTE • 18 BRILLANTE User Manual, 59300023, rev005...
  • Page 20: Ca_Section

    Define the CA section to be included in corresponding CA table. The section has to be defined in <CA_SECTION> section otherwise an error will be reported. Multiple sections can be defined separated with the tabulator. Configuring the BRILLANTE • 19 BRILLANTE User Manual, 59300023, rev005...
  • Page 21: Example Configuration, Si.conf

    CA_PID Private_data_bytes CA_DESC1 0x0B00 CA_DESC2 0x0606 </CA_DESCRIPTORS> <CA_SECTION> </CA_SECTION> Section_Name version current_next Descriptor(s) CA_SECTION_1 CA_DESC1 CA_DESC2 <CAT> Server Name repetition_rate Data ID Data_Stream_ID CA_section(s) local_Bril 4000 0x1003 0x0003 CA_SECTION_1 </CAT> Configuring the BRILLANTE • 20 BRILLANTE User Manual, 59300023, rev005...
  • Page 22: Monitoring The Brillante

    Monitoring the BRILLANTE Main CONTROL console menu At the Command prompt [system@Brillante system]$ enter the monitoring mode by typing: monitor You will get a following display: ******************************************* Brillante Monitor ver 1.0.1 built Nov 11 2004 13:08:00 ******************************************* Connected... > Available commands: Main CONTROL console menu shows the following lines.
  • Page 23: Built In Features

    - clear EMM connection(s) counter(s) show eoip - show EMM over IP connection(s) print stat - print statistics print log - print error log enable log - enable error logging Monitoring the BRILLANTE • 22 BRILLANTE User Manual, 59300023, rev005...
  • Page 24: Sigen Console Menu

    - shows all connections print log - print error log enable log - enable error logging disable log - disable error logging help - print help on commands quit - exit sigen Monitoring the BRILLANTE • 23 BRILLANTE User Manual, 59300023, rev005...
  • Page 25: Spare Ecmg In Brief

    ECMg is lost. The switching occurs when main ECMg address (IP address: Port) has made a TCP/IP level disconnection and Brillante is not able to re-connect that address anymore after number of retries (configurable). Also the switching will happen automatically if Brillante has never been able to connect the main address.
  • Page 26 0x0B000000 10.2.14.4:1028 spare_ECMg </ECMG_LIST> First line defines the spare_ECMg and in second line it has been taken in use to backup main_ECMg. Figure 1. Redundant system, both CA and Brillante included. main ECMg spare ECMg Satellite dish EMMg STACCATO eth0...
  • Page 27: Brillante 1+1 Backup In Brief

    A route to DIVISI has to be added to the -file static-routes so that BRILLANTE is able to switch the ATM to backup interface. [admin@Brillante2 admin]$ more static-routes eth0 net 10.136.30.0 netmask 255.255.255.0 gw 10.136.5.5 eth0 net 10.136.10.0 netmask 255.255.255.0 gw 10.136.5.5 Interfaces on DIVISI are as follows: 1.
  • Page 28: Configuration File

    The <BRILLANTE> </BRILLANTE> delimited field contains the IP addresses of the devices needed in a standard BRILLANTE 1+1 backup configuration. The first IP is the eth1 (in Linux and marked as 2 in the back panel) of the BRILLANTE (main unit) that is used on normal condition.
  • Page 29 This has to be disabled when the system is up and running. For some special purposes the user can define a start up delay for BRILLANTE. In other cases this should be left to 10 seconds. Lowering Execute interval reduces backup trigger delays.
  • Page 30: Triggers

    Backup BRILLANTE switches when it detects that main BRILLANTE is not online anymore. If backup unit loses power, main Brillante has to make sure that it is not a network disconnection. So main has to close application processes & eth0 for a while if backup tries to get online. After a while main will resume, if backup has not become online.
  • Page 31: Other Tips

    • startup.bril.conf Update has to be run every time the configuration is altered on the main BRILLANTE. Otherwise when take-over occurs backup will use old configuration and some services might be lost. It will also generate a backup of the old configuration to /teleste/backup/.
  • Page 32: Legal Declarations

    Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. The software as described in this document is supplied only under a licence agreement. The software may be used or copied only in accordance with the terms of the agreement.