5.2.9
Enabling the WriteCache
You may enable the RAID controller's WriteCache option to improve the data
transmission performance.
When you enable WriteCache, you may lose data when a power interruption
occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
From the Management Menu, select Objects > Adapter, then press <Enter>
1.
to display the adapter properties.
Select WriteCache, then press <Enter> to turn the option On (enabled).
2.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
3.
When finished, press any key to continue.
ASUS DSAN-DX
Rebuild Rate
Objects
Chk Const Rate = 30
Adapter
FGI Rate
Virtual Drive
BGI Rate
Physical Drive
Disk WC
Read Ahead
Bios State
Stop On Error = No
Fast Init
Auto Rebuild
Auto Resume
Disk Coercion = 1GB
Factory Default
Adapter 0
= 30
= 30
= 30
= Off
= On
= Enable
= Enable
= On
= Enable
5-29