Drolet EASTWOOD 1500 Owner's Manual page 25

Epa wood stoves
Hide thumbs Also See for EASTWOOD 1500:
Table of Contents

Advertisement

7- Once you have cut through your roof and framed the joists, it is time to work outdoors.
Authorities require that the chimney extend not less than 3 feet above the highest point
where it passes through the roof of a building and not less that 2 feet above any portion of
the building within 10 feet. You will need to install a roof flashing. The roof flashing slides
over your chimney pipe and goes under your shingles. Once you have done that, check that
everything is plumb, and nail the flashing into the roof deck. Seal the joint between the
shingles and the plate with silicone.
8- Next, slide the storm collar down the chimney until it contacts the flashing. Tighten the nut
and bolt and seal the collar to the chimney with a waterproof, non-combustible silicone
sealant. Finally, twist on your rain cap and you can head back inside. If the chimney extends
more than 5 feet above the roof deck, roof guys with telescoping legs and draw bands are
required.
9- You are now ready to connect your chimney to your stove. Simply install the inter-connecting
stove pipe between the stove pipe adapter and the stove. You can follow the instructions in
the following section (section 2.3) of this manual called « CHIMNEY CONNECTOR».
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

1800Eastwood 1800 epaSaharaSahara db03505Eastwood 1800

Table of Contents