The flow cell comes fully assembled in the box. It is setup to
use with the 3/8" tubing provided; however, other sized tubing or
1/2" hard plumbing can be used. To use alternative tubing,
remove the 90° on/off valves and plumb according to the appli-
cation.
1. If using a saddle clamp, drill a 7/16" hole in the pipe on
the pressure side of the pump. Thread the 1/8" Jaco fitting
(#2 in diagram below) through the clamp (#3) and place the
nylon jam nut (#4) onto the Jaco fitting. Slide the pipe seal
washer (#5) onto the end of the Jaco fitting. Insert the com-
pleted assembly into the hole in the pipe and tighten the
clamp. Test for leaks.
If the pipe is larger than 2" in diameter, two clamps joined
together will be required per each hole.
5
If using a pipe tap, drill a 7/16" hole and tap a 1/4" NPT
hole. Apply RTV silicone, teflon stick or teflon paste to the
threads on the Jaco fitting and screw securely into the pipe.
Test for leaks.
2.. Cut the tubing (#1) to the appropriate length. Slightly loosen
the Jaco fitting in the pipe and insert the tubing into it. Take
the free end of the tubing and insert it into the Jaco fitting
on the flow switch side of the flow cell.
3. Complete these steps for the return side of the flow cell.
Use the appropriate remaining parts to complete this task.
Take the free end of the tubing and insert it into the Jaco
fitting on the outlet side of the flow cell.