Radiant Communications DL221 Series User Manual

10/100 ethernet transceiver

Advertisement

SERIES DL221
10/100 ETHERNET TRANSCEIVER
USER MANUAL
Radiant Communications Corporation
P.O. BOX 867 • 5001 Hadley Road • South Plainfield, NJ 07080
800.969.3427 • Fax 908.757.7666
• www.rccfiber.com
E-mail:
sales@rccfiber.com
RADIANT COMMUNICATIONS CORP. DL221 REV B4.3
7/04
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL221 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Radiant Communications DL221 Series

  • Page 1 SERIES DL221 10/100 ETHERNET TRANSCEIVER USER MANUAL Radiant Communications Corporation P.O. BOX 867 • 5001 Hadley Road • South Plainfield, NJ 07080 800.969.3427 • Fax 908.757.7666 • www.rccfiber.com E-mail: sales@rccfiber.com RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 2 10/100 BASE – TX 100BASE TX PORT RJ-45 CONNECTOR HALF/FULL DUPLEX SUPPORT VIA AUTO-NEGOTIATION OR MANUAL 100m OVER UTP/STP 100ohm CAT.5 CABLE MDI-II/MDI-X SELECTION X – CROSS OVER CABLE II – STRAIGHT CABLE RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 3 LINK FX LED NOT LIT – CHECK LIGHT LEVEL IN AND OUT OF UNIT. REFER TO THE SPEC. LABEL FOR PROPER LEVEL. TP LED NOT LIT - CHECK SETTING FOR STRAIGHT / X-OVER CABLE. RESET POWER. RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 4 10/100 BASE – TX 100BASE TX PORT RJ-45 CONNECTOR HALF/FULL DUPLEX SUPPORT VIA AUTO-NEGOTIATION OR MANUAL 100m OVER UTP/STP 100ohm CAT.5 CABLE NODE MDI-II/MDI-X SELECTION NODE - CROSS OVER CABLE HUB - STRAIGHT CABLE RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 5 RWR LED NOT LIT - CHECK POWER SUPPLY. ENSURE OUTPUT 5VDC. L LED NOT LIT - CHECK LIGHT LEVEL IN AND OUT OF UNIT. REFER TO THE SPEC. LABEL FOR PROPER LEVEL. A LED NOT LIT – CHECK TWISTED PAIR CONNECTIONS. RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 6: Specifications

    100/240 VAC.50/60 Hz 5VDC wall Power consumption: 5 W max. Operating temperature: 0˚-45˚C (32˚-113˚F) Storage temperature: -30˚- 65˚C (22˚ - 149˚F) Humidity: 10-90% non-condensing NOTE - Specifications subject to change without prior notice. RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...
  • Page 7 For higher optical budgets and distances, CWDM and DWDM systems, contact factory Radiant Communications Corporation P.O. BOX 867 • 5001 Hadley Road • South Plainfield, NJ 07080 800.969.3428 • Fax 908.757.7666 • www.rccfiber.com E-mail: sales@rccfiber.com RADIANT COMMUNICATIONS CORP. DL221 REV B4.3 7/04...