TRANSFORMER WIRING

120 VAC WIRING
For 120 VAC input power to the unit, connect the black wire to the "L1" or hot leg of the power supply. Connect
the white wire to the "Ret" or neutral leg of the power supply. Attach the wire nut to the red wire. There should
be no connection to the red wire for 120 VAC operation. For Lo NOx pool heaters attach a wire nut to each
red wire independently.
120V ATMOSPHERIC HEATER
HOT
L1
BLACK
RETURN
SUPPLY
or
SIDE
NEUTRAL
WHITE
GROUND
GREEN
240 VAC WIRING
For 240 VAC input power to the unit, connect the black wire to the "L1" or hot leg of the power supply. Connect
the red wire to the "L2" or second hot leg of the power supply. Attach the wire nut to the white wire. There should
be no connection to the white wire for 240 VAC operation. For Lo NOx pool heaters attach a wire nut to
each white wire independently.
WARNING:
DO NOT attempt to operate the heater at 208 VAC.
240V ATMOSPHERIC HEATER
HOT
L1
BLACK
HOT
SUPPLY
L2
SIDE
RED
GREEN
Heater must be electrically grounded and bonded in accordance with local codes, or, in the absence of local
codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70. (Canada - Canadian Electrical
Code, CSA C22.1, Part 1 and Part 2.)
NOTE: If the transformer's primary side is wired for 120 VAC and 240 VAC is applied, damage to the trans-
former and PC board may result. Such damages are not covered under manufacturer's limited warranty.
NOTE: Input power to the heater (120 or 240 VAC) can be supplied from the load (pump) side of time clock or
directly from the GFCI power source. It is preferred that full-time power be supplied to the heater from the
GFCI power source, and that the heater be controlled by the fireman's switch connection or using a two
or three-wire remote. See pages 36-38. If using a switched GFCI power source, the heater could display false
service indicators on the display panel if the pump is turned off.
BLACK
WHITE
HEATER
4 WIRES
GREEN
RED
BLACK
RED
HEATER
4 WIRES
GREEN
WHITE
120V LOW NOx HEATER
L1
SUPPLY
RETURN
or
SIDE
NEUTRAL
240V LOW NOx HEATER
L1
SUPPLY
L2
SIDE
GROUND
27
BLACK
HOT
BLACK
BLACK
WHITE
WHITE
WHITE
GREEN
GREEN
RED
RED
BLACK
HOT
BLACK
BLACK
RED
HOT
RED
RED
HEATER
7 WIRES
GREEN
GREEN
WHITE
WHITE
HEATER
7 WIRES