Page 4
Checking your blood sugar regularly can make a big difference in how you manage your diabetes on a daily basis. We’ve made it as simple and comfortable as possible. ACCU-CHEK meters are easy to use, and you can adjust the ACCU-CHEK Softclix lancet device to make testing more comfortable.
Page 5
( diagnostic use). It should not be used to diagnose diabetes. • Be sure to use only ACCU-CHEK Comfort Curve test strips or ACCU-CHEK Advantage test strips with the meter. Other test strips may produce inaccurate results. •...
Page 6
Health-Related Information • Certain substances can interfere with the ACCU-CHEK Advantage blood glucose system and cause falsely high results. For example, if you use peritoneal dialysis solutions containing icodextrin (such as EXTRANEAL), or take certain immunoglobulin therapies that contain maltose (such as Octagam 5%), it will cause inaccurate results.
Page 7
Do not use this device to measure blood glucose in people who are experiencing cardiovascular collapse (severe shock) or decreased peripheral blood flow. • Children should be taught how to use the meter and any other medical products appropriately. ACCU-CHEK Customer Care Service Center 1-800-858-8072...
About the Control Solution ....................19 Running a Control Test .......................20 Understanding Control Test Results ..................21 Chapter 3: Testing Your Blood Sugar.................23 Preparing the ACCU-CHEK Softclix Lancet Device ...............23 Running a Blood Sugar Test....................25 Flagging Test Results......................27 Recording Your Results.......................27 Storing Your Supplies ......................27...
Page 9
Maintenance and Testing....................33 Cleaning Your Lancet Device ....................33 Screen Messages and Troubleshooting................34 Chapter 6: Technical Information................38 Product Limitations......................38 Specifications ........................38 Product Safety Information....................39 Warranty..........................40 Additional Supplies ......................44 Information for Professional Caregivers................45 Index ..........................46 Contents ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Chapter 1: Understanding Your New System* Display – On/Off Button – Computer Shows blood sugar Press this button to Port turn the meter on or results, messages, and results stored off. in memory. Code Key in Slot – Left and Right Insert code key Test Strip Slot –...
Page 11
Silver-colored bars Protective Cover Yellow Window Test Strip Lancet Test Strip Vial Cap with Comfort Dial Release Button Depth Selection Lancet Device Ejector Plunger...
• If there is no strip in the meter, it turns off automatically after and must be changed to do a 90 seconds. blood test. Chapter 1: Understanding Your New System 10 10 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
“set” appears, and then release it. The word “On” and the beeper symbol appear. 3. Press and release to see the hour flash in the upper left corner. Chapter 1: Understanding Your New System ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 14
(The flashing number is the one that can be changed.) 6. Press and hold down finish setup. The flashing test strip appears. Chapter 1: Understanding Your New System 12 12 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
The word “On” and the beeper symbol appear. 3. Press and release either to turn the beeper off. 4. Press and hold down until “set” disappears. The flashing test strip “---” appears. Chapter 1: Understanding Your New System ACCU-CHEK Customer Care Service Center 1-800-858-8072...
3. Press repeatedly until “Hypo” 7. Press and hold down until “set” flashes and “OFF” and “set” appear. disappears and the flashing test strip or “---” appears. Chapter 1: Understanding Your New System 14 14 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
• If the code number on the display does not match the code number on the test 4. Make sure the code on the strip vial, call the ACCU-CHEK Customer display matches the code on the Care Service Center at 1-800-858-8072.
Using Your Test Strips You may use either ACCU-CHEK Comfort Curve or ACCU-CHEK Advantage test strips with this meter. For accurate results, use only these test strips. • Replace the code key and run a control test every time Throw the test strips away. If the “Use By” date is you begin using a new box of test strips.
Touch and hold a drop to the edge – Yellow window completely. not the top – of the yellow window. This owner’s booklet will help you learn to test with ACCU-CHEK Comfort Curve test strips. Using ACCU-CHEK Advantage Test Strips Silver-colored bars Yellow window Touch and hold a drop to the top –...
Page 20
Chapter 1: Understanding Your New System ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Make sure you use the control solution that • Never use control solution that has expired. matches your test strips (for example, ACCU-CHEK • Control solution can stain clothes. If you spill it, Comfort Curve control solution (blue liquid) with wash your clothes with soap and water.
Level 2 test. Simply repeat Steps 3 through 6, using Level 2 control solution. If you do not have Level 2 control solution, you can purchase control solutions separately. For more information, see “Additional Supplies.” Chapter 2: Control Testing ACCU-CHEK Customer Care Service Center 1-800-858-8072...
If the control result is NOT within the acceptable range, the control test result will alternate with “Err” on the display. See the following page to find out why your control result is out of range. Chapter 2: Control Testing ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 24
Repeat the test within the appropriate temperature range. Repeat the control test with a new test strip. If the result still isn’t within the acceptable range, contact the ACCU-CHEK Customer Care Service Center at 1-800-858-8072. Chapter 2: Control Testing ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Chapter 3: Testing Your Blood Sugar Preparing the ACCU-CHEK Softclix Lancet Device 3. Twist off the lancet’s 1. Pull off the cap. 2. Insert a lancet until it clicks. protective cover.
Page 26
Try different settings to find the one that’s right for you. • Always use a new lancet for every test. • To reduce the risk of infection, never share your lancet device with anyone. Chapter 3: Testing Your Blood Sugar 24 24 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
4. Make sure the code on the meter matches the code on the test strip vial. 5. When you see the flashing blood drop, hold the lancet device against the side of your fingertip and press the release button. Chapter 3: Testing Your Blood Sugar ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 28
10. Slide out the ejector to discharge the lancet into a puncture-proof container. For more information about your test results, see “Flagging Test Results.” Chapter 3: Testing Your Blood Sugar 26 26 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Never store test strips in areas of extreme temperatures (cold or high heat) or moisture, such as the kitchen, bathroom or laundry room – heat and moisture can damage them, and lead to inaccurate results. Chapter 3: Testing Your Blood Sugar ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Two hours after meals, the blood glucose range for an adult without diabetes is less than 140 mg/dL. For people with diabetes: Please consult your doctor for the blood glucose range appropriate for you. Chapter 3: Testing Your Blood Sugar 28 28 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
2. Repeat a blood sugar test (see “Testing Your Blood Sugar”). 3. If your blood sugar results still don’t reflect the way you feel, call your doctor immediately. Chapter 3: Testing Your Blood Sugar ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Chapter 4: Using Your Meter’s Memory Viewing Test Results Storing Test Results Your meter automatically stores up to 480 test 1. Press and release either (left or results, and you can review them at any time. right arrow button) to enter the meter’s memory.
We offer a variety of software and cables to help you download the results from your meter to your personal computer or PDA. For a list of software and cables that are compatible with your meter call the ACCU-CHEK Customer Care Service Center at 1-800-858-8072. You can also access our website at www.accu-chek.com for more information.
Chapter 5: Maintenance and Troubleshooting Cleaning Your Meter Caring for your ACCU-CHEK Advantage meter is easy – just keep it free of dust. But if you need to clean it, following these guidelines carefully will help you get the best performance possible: Do Not •...
Cleaning Your Lancet Device To clean the ACCU-CHEK Softclix lancet device, use a mild dishwashing liquid mixed with water and a soft cloth. DO NOT place the entire device under water. At least once a week, disinfect the cap after cleaning by placing it in 70% alcohol (isopropyl) for 10 minutes.
▲ Never make treatment decisions based on an error message. If you have any concerns, please call the ACCU-CHEK Customer Care Service Center at 1-800-858-8072, 24 hours a day, 365 days a year. The meter isn’t coded or the The meter is ready for a drop of code key isn’t all the way in.
Page 37
Blood sugar is lower than the the operating temperature range of the measuring range of the system. system. See “Understanding Your Test Results.” Chapter 5: Maintenance and Troubleshooting ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 38
If the message reappears, call the ACCU-CHEK Customer Care Service Center at 1-800-858-8072. examples Chapter 5: Maintenance and Troubleshooting 36 36 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 39
The meter has lost all test results in memory. Turn the meter off, then on again. If you still see this display, call the ACCU-CHEK Customer Care Service Center at 1-800-858-8072. Chapter 5: Maintenance and Troubleshooting ACCU-CHEK Customer Care Service Center 1-800-858-8072...
One 3-volt lithium battery type 2032 (CR 2032, DL 2032 or equivalent) Data port Multiplexed TTL UART Protection class Meter type The ACCU-CHEK Advantage meter is suitable for continuous operation Blood volume Refer to the test strip package insert Measuring range Refer to the test strip package insert...
Please refer to safety-related (CR 2032) Laboratories, Inc.‚ in accordance 98/79/EC on notes in the manual with UL 3101-1 and CAN/CSA diagnostic medical devices. accompanying this instrument. C22.2 No. 1010-1. Chapter 6: Technical Information ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 42
Roche Diagnostics will replace it with a new ACCU-CHEK Advantage meter or equivalent product free of charge. The warranty of the replacement meter will expire on the date of the original warranty expiration or 90 days after the shipment of a replacement system, whichever period is longer.
Page 43
This warranty does not apply to the performance of an ACCU-CHEK Advantage meter that has been damaged by accident or has been altered, misused, tampered with, or abused in any way. Roche Diagnostics will handle meters that show damage or abuse according to its Non-Warranty Service Policy described below.
CAUTION: A RESTRICTED LICENSE LIMITS USE OF THE ACCU-CHEK ADVANTAGE SYSTEM – READ CAREFULLY THE LIMITATIONS RECITED BELOW. The ACCU-CHEK Advantage system (meter, including the code key, and test strips) and its use are protected by U.S. Patent Nos. 5,508,171; 5,053,199; 5,288,636; 5,405,511; 5,366,609; 5,762,770 (applies only to Advantage test strips) Re.
If you do not agree to the terms and conditions of the restricted license, you may return, at the place of purchase, the unused ACCU-CHEK Advantage system for a full refund. If you have any questions, please call the ACCU-CHEK Customer Care Service Center at 1-800-858-8072.
We suggest that you also remove the batteries before disposing. 1 Directive 2002/96/EC (Directive on waste electrical and electronic equipment (WEEE)). 2 29 CFR 1910.1030 – Bloodborne pathogens. Chapter 6: Technical Information 45 45 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
18, 44 hyperglycemia, 29 supplies, 44 control test results, hypoglycemia, 29 sweating, 29 understanding, 21–22 lancet device, 23–24, 44 symbols, 39 control test, acceptable lancet, 23, 44 range, 21 technical information, 38–39 Index ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 49
29 test strips, ACCU-CHEK Advantage, 17 test strips, ACCU-CHEK Comfort Curve, 17 thirst, increased, 29 time and date, setting, 11–12 tingling, 29 trembling, 29 troubleshooting, 32–37 warranty, 40– 43 Index 47 47 ACCU-CHEK Customer Care Service Center 1-800-858-8072...
Page 50
Notes Notes ACCU-CHEK Customer Care Service Center 1-800-858-8072...