7.5 GPP Wiring Diag ..........39 9.0 GPP Wiring Diag ..........40 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
Ranging from 1.5 to 9kW, Smith-Root manufactures electrofishers to handle all fresh or brackish water conductivities. A complete electrofishing system consists of an engine, a generator, an electronic pulsator, an anode, a cathode, cables, and switches.
MOISTURE: Do not stand the unit in water or on wet ground. Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact Protect electrical equipment from excessive moisture that will product manufacturer for return instructions.
However clocks and other timing devices and will not keep perfect time when used on generators. MODIFICATIONS to the power supply that are not Smith-Root authorized may impair the function and safety of the unit. ELECTROFISHER CONTROLS MODE: selects the type of output pulses.
20. To avoid burns or fires let the power supply cool before and allow it to cool prior to refueling. Never fuel the engine Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact transporting. When transporting, turn the fuel valve to the OFF while it is hot or running to avoid fire, explosion, bodily injury, product manufacturer for return instructions.
ANODE #1 Boat Hookup with Boom Arrays and one Anode Boom RCB-6B GPP Electrofisher JUNCTION BOX CATHODE ANODE #2 SMITH-ROOT INC. VANCOUVER WA. Anode poles always have their Input from RCB-6B own switch on the handle GPP electrofisher Stake cathode Generator...
7.5 GPP Wiring Diag ..........39 9.0 GPP Wiring Diag ..........40 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
4. Be sure generator is located properly. Generator brushes sparking 1. Check stator winding or field winding for shorts. WARNING: Always remove the engine ignition cable before checking or repairing the power supply to prevent it from accidentally starting. www.smith-root.com...
20" x 15" x 16" 20" x 15" x 16" Dimensions Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
Motor base/Mounting base 5.0, 7.5 & 9.0 06252 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty. Rubber Engine Mount Kit...
USER’S MANUAL MISC. PARTS GENERATOR ANTI-VIBRATION MOUNTING All Models Line #04084 Item Description Model Mounting bracket Rubber mount Bolt www.smith-root.com...
7 - ANNUNCIATOR VOLUME: Controls the volume of the audio output warning signal. Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact 8 - HIGH VOLTAGE: Red indicator lamp shows when voltage is present on output power terminals.
ELECTROFISHING SAFETY & PRINCIPLES Since 1964, the leader in effective, safe, and reliable products for fisheries conservation. Knowledgeable field biologists depend upon Smith-Root equipment.
7.5 GPP Wiring Diag ..........39 9.0 GPP Wiring Diag ..........40 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
As oppor tu nities arise, all Asphyxia crew members should attend a course in basic life-support Asphyxia is caused by contraction of the chest muscles. training. www.smith-root.com...
6. If you get water in boots, waders, or gloves, stop work Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact 4. Don’t operate generators without covers or screens. immediately and get dry clothing product manufacturer for return instructions.
In this case the distortion is caused by the current concentrating in the water surrounding the fish. In both (b) and (c) not as much power is transferred into the fish’s body as in (a). www.smith-root.com...
Page 21
25% duty cycle, the average Theoretically high conductivity could be dealt with by Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact power would be approximately 25% of the instantaneous using smaller electrodes, but this would reduce the range product manufacturer for return instructions.
Duty-cycle is the percent of on-time. It is a product towards the anode, called galvanotaxis. of the pulse width and the pulse frequency. The Smith-Root Programmable Output Waveforms give you duty-cycle can be lowered in three ways: by reduc- complete control over your electrofisher output. This...
• Larger electrodes have lower resistance, need more current at given voltage, reach out farther, and have lower Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact maximum voltage gradient. product manufacturer for return instructions.
Page 24
6'x6'. Figure 10 illustrates the variation in both voltage and gradient between the electrodes. Whenever possible, the cathode should be placed in parts of the stream that you do not wish to fish, or even in parts www.smith-root.com...
Figure 11. Bottom mounted cathode plate on SR-6. Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
Boats have flood lights on see a fish in fast flowing water, and operators can loose the bow to attract the fish and to help locate stunned fish. their footing. Flows greater than 5 feet per second usually produce poor electrofishing efficiencies. www.smith-root.com...
6. D. W. Novotny and G. R. Priegel, 1971 “A Guideline for Portable Direct Current Electrofishing Systems,” Technical Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact Bulletin No. 5l, Department of Natural Resources, Madison, product manufacturer for return instructions.
Page 28
Test GPP Control Box ............. 31 Test GPP Control Box- Cont........... 32 Flashing the Rotor ............33 Building a Test Load ............34 5.0 GPP Wiring Diagram ..........35 7.5 GPP Wiring Diagram ..........36 9.0 GPP Wiring Diagram ..........37 www.smith-root.com...
7.5 GPP Wiring Diag ..........39 9.0 GPP Wiring Diag ..........40 Fig. 1.2 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. IMPORTANT!: High voltages are present when generator is running. Only qualified All Smith-Root, Inc.
Page 30
1&3 5&6 Fig. 2.3: 9.0 GPP IMPORTANT!: High voltages are present when generator is running. Only qualified personnel should attempt high voltage measurements. We suggest forming a barricade around the test area and posting appropriate high voltage warning signs. www.smith-root.com...
9.0 GPP Wiring Diag ..........40 Fig. 3.3 Rectifier Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
If resistance varies significantly from above, take mea- surements directly from the slip rings. • Check Rotor Slip Rings to ground (OPEN connection). Fig. 4.2 (See Fig. 4.3). Replace rotor if measurements are out of specifications. Figure 4.2 Go to procedure 5. Fig. 4.3 Figure 4.3 www.smith-root.com...
Replace rotor bearing support bracket if old type. Contact Smith-Root, Inc. for further information. Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
ZERO ohms with the switch on. If it does not you may have a broken wire or a bad switch inside the pedal. If foot switch is inoperative, return to Smith-Root, Inc. for service. Test dual foot switches with an ohmmeter using the same method as shown above. Connect the...
* The “N” cell batteries should be replaced EVERY five years (See Fig. 7.2). Fig. 7.2 Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. All Smith-Root, Inc. manufactured products are covered by a one year warranty.
The left brush is connected to the inner windings. (See Fig.8.1). Connect the 12 Volt Battery’s positive lead to the left brush terminal. Next, hold the negative lead 12 Volt Battery to the right brush terminal for a minimum of ten seconds. This will re-magnetize the Rotor. www.smith-root.com...
Plates • If the amp meter starts to show a decrease in amps or is Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact Fig. 9.2 product manufacturer for return instructions. erratic as the “Percent of Range” nears 100% the generator is over-loading.
Page 38
(Pairings of Odd # on Left & Even # on Right.) on Right.) Output @ Binding Posts Output @ Binding Posts Black wires 12 Volts @ 500 VA Black wires 12 Volts @ 500 VA White wires 12 Volts @ 500 VA White wires 12 Volts @ 500 VA www.smith-root.com...
11 - 12 = 115 Volts @ 1250 VA (Pairings of Odd # on Left & Even # on Right.) Items manufactured by companies other than Smith-Root carry the original manufactures warranty. Please contact product manufacturer for return instructions. Output @ Binding Posts All Smith-Root, Inc.
Page 40
1 - 2 = 67 Volts @ 1500 VA White wires 12 Volts @ 500 VA Respectively through 11 - 12 = 67 Volts @ 1500 VA 4-Pin Connector 110 Volts AC (Pairings of Odd # on Left & Even # on Right.) www.smith-root.com...
Page 41
® SMITH-ROOT, INC. 14014 NE Salmon Creek Ave. Vancouver, WA 98686 USA 360.573.0202 Voice 360.573.2064 FAX info@smith-root.com www.smith-root.com...
Need help?
Do you have a question about the GPP 2.5 and is the answer not in the manual?