Do not leave the batteries lying around in the open; there is the risk of them being swallowed by children
or domestic animals. If swallowed, consult a doctor immediately.
Make sure that the polarity is correct when inserting the batteries.
Remove the batteries when the device is not being used for long periods of time.
Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protective
gloves.
Batteries must not be short-circuited or thrown into fire. There is a risk of explosion!
Never take the batteries/ apart!
Always exchange the complete set of batteries; do not mix full batteries with empty/half-empty batteries. Never use batteries
and accumulators together.
• Open the battery compartment on the back of the IR thermometer by sliding it in the direction of the arrow.
• Insert two micro-batteries (AAA) in the battery compartment observing the correct polarity. You will find the corresponding
illustration in the battery compartment.
• Close the battery compartment in reverse order.
• If the battery icon appears on the display, exchange the batteries immediately to prevent false measuring results.
Initial
operation
Initial
Initial operation
Initial
operation
operation
Operating
Operating
Operating
Operating principle
principle
principle
principle
IR thermometers measure the surface temperatures of objects. The device's sensor measures the emitted, reflected and
penetrated
heat radiation of the object and converts this information into a temperature value.
Measuring
Measuring
temperatures
temperatures
Measuring
Measuring temperatures
temperatures
Direct the opening of the IR sensor onto the object or surface to be measured and press „MEAS" (5).
As long as the button is kept depressed, the temperature is measured and displayed (the display shows „SCAN"). The last
measured value is displayed on the LC display (the display shows „HOLD").
The IR thermometer shuts off automatically after approx. 12 seconds. Make sure that the surface to be measured is larger
than the measuring spot. The ratio of the distance to spot ratio (D/S) is 6:1 with this IR thermometer. This means, that with a
measuring distance of 60 cm, the measuring spot has a diameter of approx. 10 cm.
For exact measuring, the measuring object should be at least twice as large as the measuring spot (hold the IR thermometer
closer to the measuring object, if applicable).
The temperature displayed by the IR thermometer is the average temperature of this measuring spot!
Activating
Activating
Activating
Activating the
the
the laser
the
laser
laser
laser
A switchable laser enables the easier positioning of the measuring spot. Make sure that the laser point is approx. 16 mm
away
from the center of the measuring spot (see sketch).
Turn the IR thermometer on (button „MEAS") and briefly press the button „LASER" (6). A small laser icon appears on the
display
(triangle with a sun icon). Now the laser is activated automatically during measuring. To turn the laser off, press the button
„LASER" (6) again and the laser icon on the display disappears again.