ABLE OF ONTENTS 500AL........1 NTRODUCTION TO THE RIVE IGHT A Note About the Concept of “Trips“............1 A Word About Safe Use ................1 DriveRight Vehicle Management Software........... 2 500AL........... 3 SING THE RIVE IGHT Using the Four Buttons................3 The Data Screens ..................
Page 4
Replacing the Battery .................31 Display Lamp .................... 32 Restarting the Trip 500AL................32 ............... 32 ROUBLESHOOTING UIDE .............. 35 ECHNICAL PECIFICATIONS & R ..........36 ARRANTY EPAIR NFORMATION One Year Limited Warranty ............... 36 Questions? Call Davis Customer Service............ 36 Page ii...
A Note About the Concept of “Trips“ Much of the data stored and displayed by the Trip 500AL is stored and displayed by “trip.” For example, you may view the maximum speed or the time spent driving over the set speed limit during a single trip.
The DriveRight Vehicle Management Software enables more detailed tracking of vehicle usage and access to some addi- tional features of the Trip 500AL. The following is a list of the Trip 500AL features which may only be accessed using the software.
SING THE RIVE IGHT This section briefly describes the use of the Trip 500AL display unit. The use of the four buttons (PLUS, MINUS, MODE, SET/ CLEAR) and the sequence of data screens and settings screens is explained. Descriptions of the information and options available from each screen are explained separately in “Data...
The Data Screens The data screens enable you to view most of the informa- tion stored by the Trip 500AL. To cycle through the data screens (in the order shown below), press and release MODE. NOTE: To view the settings screens, press and hold MODE until the Last Correct Security Code Entry screen appears.
YEAR SETTINGS SETTINGS CLEAR LOG Year Entry Clear Log DAY.MO SETTINGS SETTINGS ALARM Date Entry Alarm On/Off SPEED km/h SETTINGS SETTINGS Time Entry Calibration SPEED km/h SETTINGS DECEL ACCEL Limit and Units Settings DriveRight Trip 500AL Settings Screens Page 5...
Calibrating from the Software (VSS Only) If you have the DriveRight Vehicle Management Software and a VSS Trip 500AL, you may quickly and accurately cali- brate the unit using the software, provided you know the pulses per mile used by your vehicle’s VSS (vehicle speed sensor).
In order to calibrate using the speedometer, you must drive steadily at 40 km/h (25 MPH) and press a button on the Trip 500AL. The Trip 500AL bases its calibration on the speed of the vehicle at the moment of calibration which it assumes to be 40 km/h (25 MPH).
Page 12
(km/h or MPH). Note that until you calibrate the Trip 500AL this speed reading will be inaccurate. The dis- tance, which appears in the lower left of the display, is not necessary for this calibration procedure.
Page 13
Trip 500AL’s speed display. Be aware that the Trip 500AL responds to changes in speed faster than most vehicles’ speedometers. To accurately com- pare, you must drive steadily at a speed for a short time.
2. Reset your vehicle’s trip meter to zero or make a note of the odometer reading. 3. Make sure you have a new trip started on the Trip 500AL (i.e., the distance travelled is 0. To forcibly start a new trip, log out (see page 14 for details).
Page 15
The distance travelled appears at the lower left of the dis- play. Note that until you calibrate the Trip 500AL, this dis- tance reading will be inaccurate. The speed reading and calibration speed, which appear on the display as well, are not necessary for this calibration procedure.
CREENS The following section explains all the information and options available in the various data screens. In addition to the options listed in the individual sections below, in every screen you have the following two options: Move to the next Data Screen Press and release MODE.
Page 17
Although you may specify the type of trip using the Trip 500AL display unit, you must have the software to view trip type information.
4- digit ID code. Before driving the vehicle, the driver must enter his or her ID code. The Trip 500AL stores the driver ID code with the rest of the trip information, which enables you to view information for each individual driver.
0000. As soon as a driver logs out, the current trip is ended and data for that trip stored in the Trip 500AL’s memory. Note that you may not log out when the vehicle is in motion.
Trip Start/End Log Screen The Trip Start/End Log Screen shows the start and end time for each trip currently stored in the Trip 500AL’s memory. To view trip times for a specific driver, enter that driver’s ID code in the Driver ID Code Entry screen. To view all trip times for the vehicle, enter ID code 0000.
Trip 500AL’s memory. To view trip speed and distance infor- mation for a specific driver, enter that driver’s ID code in the Driver ID Code Entry screen.
Press PLUS to page forward through stored trip information. Hold the button down to increase the speed at which the Trip 500AL pages. When you reach the first or last stored trip, the Trip 500AL will no longer page in that direction.
Press PLUS to page forward through stored trip information. Hold the but- ton down to increase the speed at which the Trip 500AL pages. When you reach the first or last stored trip, the Trip 500AL will no longer page in that direction.
Limits Screen The Limits screen enables you to view the set speed, acceler- ation, and deceleration limits for this Trip 500AL unit. You may not change any of the limits from this screen; limits may only be changed from the Limits and Units Setting screen (see “Time Entry”...
Press and hold MODE. Last Correct Security Code Entry Screen The Trip 500AL records the date and time that a correct code was last entered. This screen allows you to detect if someone learns the code and uses it to access the settings screens or simply to determine the last time you entered the correct code.
If you are concerned about unauthorized changing of Trip 500AL settings, you may enter a security code from the DriveRight Vehicle Management Software. The Trip 500AL will not allow access to the rest of the settings screens until the correct 4-digit security code is entered. The unit allows five attempts to enter the correct security code before...
Current Readings screen and activates the tamper indicator. Set or Change the Security Code Use PLUS and MINUS to enter your current code (if you are entering a security code for the first time, make sure 0000 is entered). Press and hold SET/CLEAR until the word CHG (change) appears on the display.
Page 28
You have the following option from the Clear Log Screen: Clear all Log Data Press and hold SET/CLEAR. The word CLR (clear) appears in the display to indicate that the unit is preparing to clear all log data. To protect against accidental clearing of data, you must press and hold SET/CLEAR for 3 seconds before the unit clears data.
SET/CLEAR, the display changes to read ON or OFF, depending on the alarm’s status. Calibration Screen The Calibration screen enables you to calibrate the Trip 500AL for your vehicle. See “Calibrating the Trip 500AL” on page 6 for details. Page 25...
Limit and Unit Settings Screen The Limit and Unit Settings screen allows you to set limits for speed, acceleration, and deceleration. You may also change the unit of measure in which speed and distance information is displayed (km/h or MPH). Speed Limit SPEED km/h...
Time Entry The Time Entry screen allows you to set the time and to select the format (12 hour or 24 hour) in which you want time dis- played. SETTINGS Time Entry Screen You have the following options from the Time Entry Screen: Set the Time Use PLUS and MINUS to set the time.
Date Entry The Date Entry screen allows you to set the date and to select the format (Day.Month or Month:Day) in which you want the date displayed. DAY.MO SETTINGS Date Entry Screen You have the following options from the Date Entry Screen: Set the Date Use PLUS and MINUS to set the date.
This information may be viewed using the software also. Tamper Protection The Trip 500AL will alert you if anyone attempts to tamper with the unit, provided that you have entered a security code other than 0000. If someone disconnects power from the unit, if an incorrect code is entered five times, or if the unit is rebooted,...
Battery Operation The Trip 500AL is designed to be taken out of your vehicle so the data may be reviewed anywhere. If you disconnect the unit from its power source (the vehicle) it will automati- cally switch to battery power. The word BAT appear in the lower left corner of all screens to indicate that you are run- ning on battery power.
This means the unit is in “sleep mode” because it is not connected to the vehicle and does not receive power from the vechicle’s bat- tery. Thus if you do not power the Trip 500AL from your vehicle’s battery, it will not record any data.
Display Lamp To read the Trip 500AL at night, use the display lamp. To toggle the display lamp on and off, press PLUS when view- ing the Current Readings screen. Be aware that the display lamp does not work when the unit is operating on battery power.
Page 37
My speed reads zero while driving. There could be a number of things wrong. Make sure the Trip 500AL is plugged in. Make sure the Trip 500AL is calibrated. Make sure the speed sensor is within 10-16 mm (3/8"- 5/8") of the magnet.
Page 38
The speed reading on the Trip 500AL agrees with my vehicle’s speedometer, but the dis- tance reading on the Trip 500AL and my odometer differ (or vice versa). For best accuracy, you should calibrate using the car’s odometer (see “Calibration Using the Odometer”...
ECHNICAL PECIFICATIONS Displays current speed in MPH or km/h. Records maximum speed for each trip. Speed Records total time in which speed exceeded set limit for each trip. Accuracy ±1%. Displays current acceleration in g’s (an acceleration of 22 MPH/sec. or 35 km/h/sec.). Acceleration Records number of times acceleration exceeded specified limit for each trip.
Connect the equipment into an outlet on a circuit different from that to which the receiver is con- nected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved in writing by Davis Instruments may void the user's authority to operate this equipment. 3465 Diablo Avenue, Hayward, CA 94545-2778 510-732-9229 •...