CS980SN
GE Café Free-Standing Radiant Range
Dimensions and Installation Information (in inches)
Electrical Requirements: 240v/208v; 60Hz, 40A
Effective January 1, 1996, the National Electrical
Code requires that new construction (not
existing) utilize a 4-conductor connection to an
electric range.
Receptacle Locations: Locally approved flexible
service cord or conduit must be used because
terminals are not accessible after range
installation. See shaded area in drawing for
location of electrical outlet box. Recommended
outlet locations allow range to be installed
directly against wall.
Note: 30" ranges conform to U.L. requirements
for 0" spacing from adjacent walls below
countertops. To reduce possibility of scorching
walls, engineering recommends a minimum of
1-1/2" spacing to allow for possible extended,
high-heat, no-load heating element operation.
Installation information: Before installing,
consult installation instructions packed with
product for current dimensional data.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
37-1/4"*
26-1/2"
37-1/4"*
46-3/4"
*41-1/4" with optional backguard kit
26-1/2"
46-3/4"
*41-1/4" with optional backguard kit
or
™
service,
30"
36-1/4"
30"
+ _
1/4
+ _
36-1/4"
1/4
Receptacle locations: Locally approved flexible service cord or
conduit must be used because terminals are not accessible after
range installation. See shaded area in drawing for location of
electrical outlet box. Recommended outlet locations allow range
to be installed directly against wall.
7
7-1/2
Receptacle locations: Locally approved flexible service cord or
conduit must be used because terminals are not accessible after
3-1/2
range installation. See shaded area in drawing for location of
REAR
WALL
electrical outlet box. Recommended outlet locations allow range
to be installed directly against wall.
2-1/4
CENTER LINE
7
7-1/2
All GE ranges are equipped with
3-1/2
an Anti-Tip device. The installation
REAR
of this device is an important,
WALL
required step in the installation
of the range.
2-1/4
CENTER LINE
Specification Created 8/08
7-1/2
5
2-1/4
7-1/2
5
2-1/4
221003