Installation Instructions
Electrical Connections
B
NEW CONSTRUCTION AND FOUR
WIRE CORD CONNECTION KIT
B3 Complete 4 wire
cord kit. Below are
step by step
instructions on
how to install the
kit.
Remove the screws on
B4
the terminal block with
a 1/4" nut driver or
phillips screwdriver.
B5
Remove the ground
B6
screw using a 5/16"
nut driver, then
remove and discard
the ground strap. Do
not discard the
ground screw, you
will need it later.
Install the four-wire
B7
cord and strain
relief through the
hole in the
connection plate.
3 Screws
Screw and
Ground Strap
Location
Strain
Relief
Connection
Clamp
Plate
Remove
3 screws
Knockout in center
of connection plate
may be taken out
Ground
Screw
4 wire
cord kit
Connection
Plate
Strain
Relief
Clamp
cont.
Attach the green lead
B8
below the junction
block with the ground
screw that was
removed earlier.
Gound
Connect the red
B9
and black leads to
the outside
terminals and the
white lead to the
center terminal.
B10 Push the cord upward (to relieve strain),
while tightening the strain relief clamp.
B11 Re-install the wire cover with the 5
screws removed earlier. Make sure the
wires do not become pinched between
the wire cover and mainback.
Ground
Strap
Three-wire connection continued on following page
6
Red or
Black
White
Red or
Black
Wire
Cover
Ground
Screw
Ground
(Green)

Hide quick links: