2-8.
Weld Parameters
Wire
Type,
Shielding
Gas,
And Flow Rate
Wire
Diameter
(inch)
Operator
Controls
Material Thickness
1/4 in.
(6.4 mm)
3/16 in.
(4.8 mm)
1/8 in.
(3.2
mm)
14 ga.
16
ga.
18 ga.
2Oga.
22
ga.
E7OS-6
CO2
2Ocfh
.023
Voltage Tap
5
4
3
3
2
2
1
Wire
Speed
70
60
50
30
20
5
0
.030
Voltage Tap
6
5
4
3
3
2
1
~
Wire
Speed
60
45
4.0
35
30
25
20
.035
Voltage
Tap
6
5
4
3
2
2
2
~
Wire
Speed
30
20
20
20
20
15
5
E7OS-6
75%
Argon
25%
CO2
2ocfh
.023
Voltage
Tap
6
5
4
3
3
2
2
1
Wire
Speed
100
90
75
60
50
35
20
10
.030
Voltage
Tap
6
5
4
3
3
2
1
1
Wire
Speed
70
60
50
40
30
20
10
0
.035
Voltage Tap
6
5
5
4
3
2
2
.
Wire
Speed
50
45
40
30
25
25
10
E71T-GS
Flux Core
.030
Voltage
Tap
6
6
5
4
3
2
2
Wire
Speed
50
45
30
20
20
10
10
.035
Voltage
Tap
6
6
5
4
3
Wire
Speed
40
40
30
20
20
ER 308
Stainless Steel
Tn-Mix
2ocfh+
.023
Voltage Tap
5
4
4
3
3
3
3
Wire
Speed
100
90
75
60
50
40
25
.030
Voltage
Tap
6
5
4
3
3
Wire
Speed
75
70
60
50
40
Do
not
change Voltage
switch
position
while
welding.
Wire
Speed
value in Table is
a
starting
value
only
and WIre
Speed
control
setting
can
be
fine
tuned
during welding.
S-181 186